Continual Self-supervised Learning Considering Medical Domain Knowledge in Chest CT Images

Ren Tasai, Guang Li, Ren Togo, Minghui Tang, Takaaki Yoshimura, Hiroyuki Sugimori, Kenji Hirata, Takahiro Ogawa, Kohsuke Kudo, Miki Haseyama

Introduction

Self-supervised learning (SSL) has emerged as a critical paradigm in medical AI, enabling models to leverage vast quantities of unlabeled data. However, medical imaging data is rarely homogeneous. In chest CT imaging, for instance, different "window settings" (such as lung vs. mediastinal views) create distinct data distributions even when capturing the same anatomy. When models are trained on these domains sequentially, they encounter two primary obstacles: catastrophic forgetting, where new knowledge overwrites previously learned features, and data interference, where distributional shifts during pretraining lead to suboptimal representations.

Researchers from Hokkaido University have developed a novel Continual Self-Supervised Learning (CSSL) framework specifically designed to address these challenges by incorporating medical domain knowledge into the learning process.

Methodology

The proposed framework utilizes a three-stage approach to ensure stable knowledge acquisition across sequential domains:

  1. Initial Pretraining: The model first learns feature representations from an initial dataset ($D_1$) using a Masked Autoencoder (MAE) architecture.
  2. Enhanced Rehearsal Buffer: To mitigate forgetting, the system maintains a buffer of representative samples from $D_1$. Unlike standard random sampling, this method employs k-means clustering to identify diverse samples. Crucially, the selection process prioritizes samples based on their Euclidean distance to the center of the subsequent domain ($D_2$), effectively selecting "bridge" samples that help the model transition between distributions.
  3. Continual Learning Phase: During training on $D_2$, the model revisits the rehearsal buffer using two key techniques:
  4. Mixup Strategy: Blending images from the buffer to enhance data diversity and regularization.
  5. Feature Distillation: The model is constrained to ensure that its new feature outputs do not deviate significantly from the logic of the initial "frozen" model, thereby preserving the integrity of the original knowledge base.

Experimental Setup

Datasets

The framework was evaluated using the J-MID (Japanese Medical Image Database) for pretraining. Two distinct domains were established based on CT window settings:

  • Domain 1 (Mediastinal Window): 31,256 images.
  • Domain 2 (Lung Window): 26,403 images.

For the downstream evaluation, the researchers used the SARS-CoV-2 CT-Scan Dataset, which contains 2,481 images for binary COVID-19 classification.

Results and Discussion

The proposed CSSL method was compared against standard MAE and MedCoSS, a state-of-the-art medical CSSL framework. The results demonstrate significant improvements in classification performance:

  • Accuracy (ACC): The proposed method achieved 0.863, outperforming MedCoSS (0.836) and simultaneous pretraining on both domains (0.792).
  • Area Under Curve (AUC): The model reached an AUC of 0.940, compared to 0.923 for MedCoSS.
  • Convergence Speed: The method demonstrated faster convergence during the fine-tuning phase compared to baseline SSL methods, suggesting more robust feature extraction.

Key Insights

A significant finding of this research is that the representativeness of the rehearsal buffer is more important than simple diversity. Prioritizing samples that are distributionally closer to the new domain allows the model to capture the underlying anatomical relationships that persist across different window settings. While the order of domain learning ($D_1 \to D_2$ vs. $D_2 \to D_1$) does impact final performance, the proposed method remained superior to existing benchmarks regardless of the sequence.

Limitations and Future Work

While effective, the current study is limited to a two-domain transition. Future research is required to evaluate the framework's scalability across dozens of scanner types and clinical protocols. Additionally, while the model excels at COVID-19 classification, its generalizability to other tasks such as organ segmentation or nodule detection remains to be explored. Finally, the computational overhead associated with maintaining a rehearsal buffer and performing feature distillation warrants further quantification for real-world clinical deployment.

Summary updated

BibTeX
@inproceedings{tasai2025continual,
  author = {Ren Tasai and Guang Li and Ren Togo and Minghui Tang and Takaaki Yoshimura and Hiroyuki Sugimori and Kenji Hirata and Takahiro Ogawa and Kohsuke Kudo and Miki Haseyama},
  title = {{Continual Self-supervised Learning Considering Medical Domain Knowledge in Chest CT Images}},
  booktitle = {IEEE International Conference on Acoustics, Speech and Signal Processing},
  year = {2025},
  url = {https://openreview.net/forum?id=C1llFoZSSN},
}
Figure