Journal of Cardiovascular Magnetic Resonance 2015

14 papers
The 2015 edition of the Journal of Cardiovascular Magnetic Resonance focused on the refinement of quantitative mapping techniques and the development of volumetric analysis methods. Research themes centered on the accuracy and precision of T1, T2, and T2* mapping, with specific attention to noise modeling and the impact of reconstruction models on myocardial tissue characterization. Notable work included joint T1 and T2 mapping sequences and investigations into how noise influences T2* measurements. Another trend involved the development of motion-corrected imaging to facilitate data acquisition, including free-breathing T2* mapping and the use of compressed sensing for single breath-hold 3D measurements of left atrial volume. Researchers also investigated multidirectional hemodynamic mapping for aortic stenosis assessment and high-resolution MRI to detect changes in left ventricular structure. Prolific contributors included Reza Nezafat, Peter Kellman, and Michael S. Hansen, whose work emphasized the integration of physics-informed modeling and stochastic sampling to support clinical decision-making.

Top Research Directions

The 20 research directions with Journal of Cardiovascular Magnetic Resonance 2015 papers, ranked by paper count, next to 2014. Share is the fraction of the edition’s papers in the direction.

#Direction20152014Share 2015Share 20142014 rank
1Reconstructing High Resolution Medical Images from Accelerated Scans5035.7%0.0%—
2Eliminating Breath-Hold Constraints in Dynamic MRI4328.6%30.0%1
3Radial K-Space Sampling for Motion Robust MRI3221.4%20.0%3
4Overcoming Geometric Approximation Error in Biomedical Modeling2014.3%0.0%—
5Overcoming Through Plane Motion in Dynamic Imaging2014.3%0.0%—
6Cross-Modal Motion Compensation for Quantitative Hybrid Imaging107.1%0.0%—
7Exploiting Temporal Redundancy in Dynamic Image Reconstruction117.1%10.0%10
8GPU Acceleration for Iterative Image Reconstruction and Registration107.1%0.0%—
9Harmonizing Radiomic Features Across Medical Imaging Platforms107.1%0.0%—
10Hierarchical Spatial Alignment for Deformable Image Registration107.1%0.0%—
11Image Registration Under Dynamic Intensity and Contrast Variations107.1%0.0%—
12Isolating Independent Effects with Multivariate Covariate Adjustment107.1%0.0%—
13Joint Optimization of Motion and Image Restoration107.1%0.0%—
14Neural Fields for Sparse View Tomographic Reconstruction107.1%0.0%—
15Quantifying Spatial Uncertainty via Generative Sampling107.1%0.0%—
16Rician Noise Modeling in Magnitude Magnetic Resonance Imaging107.1%0.0%—
17Separating Phase and Amplitude in Functional Data Analysis107.1%0.0%—
18Shape Morphometry for Localized Structural Deformations107.1%0.0%—
19Template Free 3D Reconstruction of Deformable Surfaces107.1%0.0%—
20The Energetic Tipping Point of Maladaptive Cardiac Remodeling107.1%0.0%—

New this year

Directions with no 2014 paper and at least 5 in 2015.

Direction2015
Reconstructing High Resolution Medical Images from Accelerated Scans5

Download all directions as CSV

Institutions

Institutions credited by Journal of Cardiovascular Magnetic Resonance 2015 papers: a paper credits every institution named in its affiliations, once. 14 institutions share 12 credited papers.

#InstitutionPapersShare20142014 rank
1Beth Israel Deaconess Medical Center 433.3%41
2Harvard Medical School 216.7%33
3National Heart Lung and Blood Institute 216.7%0—
4National Institutes of Health 216.7%0—
5Centre Hospitalier Universitaire Vaudois 18.3%0—
6Centre Inria d'Université Côte d'Azur 18.3%0—
7Duke-NUS Medical School 18.3%0—
8Harvard University 18.3%112
9Imperial College London 18.3%113
10IMT School for Advanced Studies Lucca 18.3%18
11National University of Singapore 18.3%0—
12Siemens Healthineers (Germany) 18.3%24
13The Ohio State University 18.3%32
14École Polytechnique Fédérale de Lausanne 18.3%0—

Download all institutions as CSV

About this data

Papers. Journal of Cardiovascular Magnetic Resonance 2015 lists 14 papers on Lacuna, duplicate versions counted once; rejected and withdrawn submissions are left out.

Directions. Directions are Lacuna’s clustering of the concept elements extracted from each paper, so a paper can belong to several and direction counts add up to more than the paper count. A direction’s share is its papers divided by the edition’s papers. Comparisons with 2014 use shares, since the edition went from 10 to 14 papers.

Institutions. A paper credits each institution named in its affiliations, resolved to a ROR record, once. 12 of 14 papers (85.7%) credit at least one institution and are the base for institution shares; the rest have no resolved affiliation yet.

Data. Counts come from Lacuna’s data build of 2026-11-18 and change as papers are added. Tables as CSV: directions · institutions. Cite as: Lacuna, “Journal of Cardiovascular Magnetic Resonance 2015”, https://lacuna.tiptreesystems.com/venue/journal-of-cardiovascular-magnetic-resonance/2015.

Top Authors

AuthorPapers
Maxime Sermesant1
Rizwan Ahmad1

Impactful Papers

Papers from Journal of Cardiovascular Magnetic Resonance 2015 that shaped research clusters.

Influential

Papers

Title
Adverse changes in left ventricular structure begin at normotensive systolic blood pressures: a high resolution MRI study
Aortic Stenosis assessment with a 3-directional phase contrast magnetic resonance technique. Comparison to transthoracic echocardiography
A segmented modified look-locker inversion recovery (MOLLI) sequence for high heart rate T1 mapping of mice
Dictionary learning for unsupervised identification of ischemic territories in CP-BOLD Cardiac MRI at rest
Free-breathing T2* mapping using respiratory motion corrected averaging
Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping
Joint myocardial T1 and T2 mapping
Local late gadolinium enhancement features to identify the electrophysiological substrate of post-infarction ventricular tachycardia: a machine learning approach
Motion correction for free breathing quantitative myocardial t2 mapping: impact on reproducibility and spatial variability
Myocardial T2* mapping: influence of noise on accuracy and precision
Precision and reproducibility of T2 quantifications in myocardial T2 mapping: impact of the number of echoes and reconstruction model
Single breath-hold 3D measurement of left atrial volume using compressed sensing cardiovascular magnetic resonance and a non-model-based reconstruction approach
Single breathhold, three-dimensional measurement of left atrial volume and function using sparse CINE CMR imaging with iterative reconstruction
Sub-8-minute cardiac four dimensional flow MRI using kat ARC and variable density signal averaging