EchoNet-Dynamic · Image Segmentation

32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Image Segmentation: proposed/measured results on test (including papers where test split is standard/implicit).

3.73.83.93.9202420252026CoReEcho: 3.9 (2024)MCSDR (vision-only): 3.76 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 24 of 24 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Single-parameter latent orbit features with supervised MLP prediction head proposedEF MAE6.02%Image SegmentationSelf-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits
Source quote
L143: We compare our approach with LMP~\cite{yangLatentMotionProfiling2026} by training an equivalent MLP head using the concatenation of its structure and motion features. Our method yields improved EF prediction performance (6.02% MAE vs.\ 6.27% MAE) with one-tenth as many pre-training epochs, indicating that the proposed cyclic prior provides a strong inductive bias for capturing motion cues relevant to cardiac function assessment. Fully supervised methods (e.g., \cite{maani2024coreecho}) act as an upper bound.
2026MCSDR (vision-only)MAE3.76Image Segmentation · split: testGenerative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video
Source quote
L191: Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89).
2026LMP features with an equivalent supervised MLP prediction headEF MAE6.27%Image SegmentationSelf-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits
Source quote
L143: We compare our approach with LMP~\cite{yangLatentMotionProfiling2026} by training an equivalent MLP head using the concatenation of its structure and motion features. Our method yields improved EF prediction performance (6.02% MAE vs.\ 6.27% MAE) with one-tenth as many pre-training epochs, indicating that the proposed cyclic prior provides a strong inductive bias for capturing motion cues relevant to cardiac function assessment. Fully supervised methods (e.g., \cite{maani2024coreecho}) act as an upper bound.
2026PanEcho baselineMAE5.35Image Segmentation · split: testGenerative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video
Source quote
L191: Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89).
2025EchoVLM proposedDice similarity coefficient (DSC)93.1%Image Segmentation · view=A4CEchoVLM: Measurement-Grounded Multimodal Learning for Echocardiography
Source quote
L134: EchoVLM outperforms tasks-specialists and achieves similar performance as vision FM. EchoVLM attains the best DSC on EchoNet-Dynamic (93.1%) and EchoNet-Pediatric-A4C (92.4%), and ties EchoApex on EchoNet-Pediatric-PSAX (93.0%) (Table \ref{tab: seg}). On the CAMUS dataset, EchoVLM matches EchoApex for left ventricular segmentation (93.8%) and achieves competitive performance for left atrial segmentation (90.2%). Visualization of segmentation results on CAMUS using EchoVLM is shown in Figure \ref{fig:camus1}. These results indicate that our pretraining maintains transferable local features for segmentation across datasets.
2025HSS-Net (full method) proposedDice92.67Image SegmentationHierarchical Spatio-Temporal Segmentation Network for Ejection Fraction Estimation in Echocardiography Videos
Source quote
L159: HSS-Net~(Ours) │ \textBF{90.47} │ \textBF{2.43±5.02} │ \textBF{93.89} │ \textBF{11.29} │ \textBF{84.50} │ \textBF{0.95±6.75} │ \textBF{92.67} │ \textBF{2.66}
2024Adaptive (w/ aug & LD) proposed non-standard sliceDice score (LV)0.910Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689
2024Adaptive (w/ aug & LD) proposed non-standard sliceDice score (LVM)0.518Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689
2024Adaptive (w/ aug & LD) proposed non-standard sliceDice score (LA)0.689Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689
2024CoReEcho proposedMAE3.90Image SegmentationCoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis
Source quote
L189: Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.}
2024CoReEcho proposedR282.44Image SegmentationCoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis
Source quote
L4: Deep learning (DL) models have been advancing automatic medical image analysis on various modalities, including echocardiography, by offering a comprehensive end-to-end training pipeline. This approach enables DL models to regress ejection fraction (EF) directly from 2D+time echocardiograms, resulting in superior performance. However, the end-to-end training pipeline makes the learned representations less explainable. The representations may also fail to capture the continuous relation among echocardiogram clips, indicating the existence of spurious correlations, which can negatively affect the generalization. To mitigate this issue, we propose \texttt{CoReEcho}{}, a novel training framework emphasizing continuous representations tailored for direct EF regression. Our extensive experiments demonstrate that \texttt{CoReEcho}{}: 1) outperforms the current state-of-the-art (SOTA) on the largest echocardiography dataset (EchoNet-Dynamic) with MAE of 3.90 \ │ R2 of 82.44, and 2) provides robust and generalizable features that transfer more effectively in related downstream tasks. The code is publicly available at \url{https://github.com/BioMedIA-MBZUAI/CoReEcho}.
2024CoReEcho proposedRMSE5.13Image SegmentationCoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis
Source quote
L189: Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.}
2024EchoONE proposedmDice88.36Image Segmentation · training=not used · evaluation=externalEchoONE: Segmenting Multiple Echocardiography Planes in One Model
Source quote
L256: EchoONE │ 73.94 │ 59.31 │ 88.36 │ 79.65
2024Adaptive (w/ aug) ablation non-standard sliceDice score (LV)0.892Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=not usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L116: Adaptive (w/ aug) │ 0.892 │ 0.319 │ 0.553
2024Adaptive (w/ aug) ablation non-standard sliceDice score (LVM)0.319Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=not usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L116: Adaptive (w/ aug) │ 0.892 │ 0.319 │ 0.553
2024Adaptive (w/ aug) ablation non-standard sliceDice score (LA)0.553Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=not usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L116: Adaptive (w/ aug) │ 0.892 │ 0.319 │ 0.553
2024SAMUSmDice91.79Image SegmentationMemSAM: Taming Segment Anything Model for Echocardiography Video Segmentation
Source quote
L187: 91.79
2023filter-pruned DeepLabV3 proposedcompression rate1148x ×Image Segmentation · compressed · params=34.5K · pruning-rate=98.4%Sculpting Efficiency: Pruning Medical Imaging Models for On-Device Inference
Source quote
L35: In Figure \ref{fig:results}, globally weight-pruned models exhibit impeccable resiliency, maintaining quality within 1% of the baseline even at a sparsity of 98.4% (633K params.). On the contrary, a local strategy (not depicted) deteriorates model quality at high targets \cite{blalock2020state}; some layers are more sensitive than others. Our filter pruning results corroborate the overarching observation that DeepLabV3 is substantially overparameterized for this task. Specifically, the most extreme case, with 98.4% filters pruned, yields DICE scores within 4% of the baseline while being 1148x smaller (34.5K params.). Moreover, the optimal filter pruned model (0.875) deviates from the baseline by only 0.7% while offering 7.5x higher throughput at 233 FPS, making it more than viable for real-time use. This model is just as fast on a CPU as the GPU baseline, a profound improvement that results solely from pruning.
2023EchoAImean absolute error4.34Image Segmentation · fine-tunedEchocardiogram Foundation Model - Application 1: Estimating Ejection Fraction
Source quote
L34: In this work, we introduce EchoAI, a foundation model for echocardiograms. We train EchoAI on a comprehensive dataset comprising 1.5 million echocardiograms. This training dataset encompasses a diverse range of adult and paediatric echocardiograms, including various types and views sourced from both public and Stanford-private datasets. We further fine-tune EchoAI on the EchoNet Dynamic dataset (\cite{ouyang_echonet-dynamic_nodate}) to estimate the ejection fraction (EF). Remarkably, Without any task-specific modifications, EchoAI demonstrates an impressive capability to estimate the ejection fraction, achieving a mean absolute error of 4.34 (9.40%). This performance is noteworthy, especially considering the inherent challenges in ejection fraction estimation. Notably, the inter-user variability for this task is typically 13.5% \cite{farsalinos_head--head_2015}. Furthermore, the process of calculating the ejection fraction involves the intricate steps of detecting individual heartbeats and manually segmenting the left ventricle at both end diastole and systole for each heartbeat, making it a highly time-consuming task.
2023EchoAImean absolute percentage error9.40%Image Segmentation · fine-tunedEchocardiogram Foundation Model - Application 1: Estimating Ejection Fraction
Source quote
L16: Cardiovascular diseases stand as the primary global cause of mortality. Among the various imaging techniques available for visualising the heart and evaluating its function, echocardiograms emerge as the preferred choice due to their safety and low cost. Quantifying cardiac function based on echocardiograms is very laborious, time-consuming and subject to high interoperator variability. In this work, we introduce EchoAI, an echocardiogram foundation model, that is trained using self-supervised learning (SSL) on 1.5 million echocardiograms. We evaluate our approach by fine-tuning EchoAI to estimate the ejection fraction achieving a mean absolute percentage error of 9.40%. This level of accuracy aligns with the performance of expert sonographers.
2022SimCLR-pretrained DeepLabV3 proposedDice score0.9252Image Segmentation · backbone=DeepLabV3 · pretraining=SimCLRContrastive Pretraining for Echocardiography Segmentation with Limited Data
Source quote
L101: 3 │ SimCLR │ DeepLabV3 │ 0.9252 (0.0476) │ 0.9242 (0.0452) │ 0.9190 (0.0509) │ 0.9125 (0.0548)
2022SimCLR-pretrained DeepLabV3 proposedDice score0.9125Image Segmentation · fine-tuned · backbone=DeepLabV3 · pretraining=SimCLR · data-fraction=5%Contrastive Pretraining for Echocardiography Segmentation with Limited Data
Source quote
L155: As Table \ref{tab:echo} shows, our proposed self supervised method which uses DeepLabV3 with a SimCLR pretrained backbone outperformed all other methods (including the EchoNet-Dynamic \cite{echonetdynamic} baseline - 0.9211 Dice), regardless of the amount of data. In fact, with only 5% of the data, our method produces results (0.9125 Dice) that are close to fully supervised training with all of the available data (0.9229 Dice). Furthermore, with the UNet architecture, SimCLR was found to be beneficial although the improvement was minor. We also found ImageNet pretraining to perform better than random initialization. However, BYOL did not have any significant benefit over ImageNet pretraining or even random initialization. Finally, DeepLabV3 performed better than UNet in the segmentation task.
2022DeepLabV3 (Ouyang et al.) baselineDice score0.9211Image Segmentation · backbone=DeepLabV3Contrastive Pretraining for Echocardiography Segmentation with Limited Data
Source quote
L31: Furthermore, \cite{ouyang2020video} attempted the same task, training on their large publicly available EchoNet-Dynamic dataset \cite{ouyang2019echonet}, containing 20,060 annotated images from 10,030 patients. A DeepLabV3 \cite{chen2017deeplab} network was chosen for this task and obtained a Dice score of 0.9211.
2022Fully supervised training baselineDice score0.9229Image Segmentation · training=fully-supervised · data-fraction=100%Contrastive Pretraining for Echocardiography Segmentation with Limited Data
Source quote
L155: As Table \ref{tab:echo} shows, our proposed self supervised method which uses DeepLabV3 with a SimCLR pretrained backbone outperformed all other methods (including the EchoNet-Dynamic \cite{echonetdynamic} baseline - 0.9211 Dice), regardless of the amount of data. In fact, with only 5% of the data, our method produces results (0.9125 Dice) that are close to fully supervised training with all of the available data (0.9229 Dice). Furthermore, with the UNet architecture, SimCLR was found to be beneficial although the improvement was minor. We also found ImageNet pretraining to perform better than random initialization. However, BYOL did not have any significant benefit over ImageNet pretraining or even random initialization. Finally, DeepLabV3 performed better than UNet in the segmentation task.