| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | EchoCoTr SOTA frontier | 3.95 | 2022-01-01 | modality=echocardiography video · LVEF estimation on ultrasound videos; split and other evaluation conditions are not s… | EchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal EchocardiographySource quoteLearning spatiotemporal features is an important task for efficient video understanding especially in medical images such as echocardiograms. Convolutional neural networks (CNNs) and more recent vision transformers (ViTs) are the most commonly used methods with limitations per each. CNNs are good at capturing local context but fail to learn global information across video frames. On the other hand, vision transformers can incorporate global details and long sequences but are computationally expensive and typically require more data to train. In this paper, we propose a method that addresses the limitations we typically face when training on medical video data such as echocardiographic scans. The algorithm we propose (EchoCoTr) utilizes the strength of vision transformers and CNNs to tackle the problem of estimating the left ventricular ejection fraction (LVEF) on ultrasound videos. We demonstrate how the proposed method outperforms state-of-the-art work to-date on the EchoNet-Dynamic dataset with MAE of 3.95 and R^2 of 0.82. These results show noticeable improvement compared to all published research. In addition, we show extensive ablations and comparisons with several algorithms, including ViT and BERT. The code is available |
| 2 | EchoGNN | 4.45 | 2022-08-01 | EF prediction; Table 1. | EchoGNN: Explainable Ejection Fraction Estimation with Graph Neural NetworksSource quote0.76 4.45 |
TaskImage Segmentation (24)Ejection Fraction Estimation (13)Video Generation (6)Ejection Fraction Regression (5)Left Ventricular Ejection Fraction Prediction (5)Binary Classification (4)Video Segmentation (4)
Showing 13 of 13 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | HSS-Net (full method) proposed | corr (Pearson correlation for EF estimation) | 84.50 | Ejection Fraction Estimation | Hierarchical Spatio-Temporal Segmentation Network for Ejection Fraction Estimation in Echocardiography VideosSource quoteL159: HSS-Net~(Ours) │ \textBF{90.47} │ \textBF{2.43±5.02} │ \textBF{93.89} │ \textBF{11.29} │ \textBF{84.50} │ \textBF{0.95±6.75} │ \textBF{92.67} │ \textBF{2.66} |
| 2025 | Single-Input Fusion proposed | RMSE | 7.02 | Ejection Fraction Estimation · split: test · architecture=Single-Input Fusion | Investigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography VideosSource quoteL285: Layer Normalization. More pronounced gains were observed with the Single-Input and Dual-Input Fusion architectures, which achieved test RMSE values of 7.02 and 7.64, respectively, both when paired with |
| 2025 | Dual-Input Fusion proposed | RMSE | 7.64 | Ejection Fraction Estimation · split: test · architecture=Dual-Input Fusion | Investigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography VideosSource quoteL285: Layer Normalization. More pronounced gains were observed with the Single-Input and Dual-Input Fusion architectures, which achieved test RMSE values of 7.02 and 7.64, respectively, both when paired with |
| 2025 | I3D-mini (B2) ablation | RMSE | 6.7954 | Ejection Fraction Estimation · variant=B2 · architecture=I3D-mini · conv2-kernel=3×3×3 | Investigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography VideosSource quoteL169: 6.7954 |
| 2025 | I3D-mini (B1) ablation | RMSE | 7.0906 | Ejection Fraction Estimation · variant=B1 · architecture=I3D-mini · conv2-kernel=1×1×1 | Investigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography VideosSource quoteL165: 7.0906 |
| 2023 | GEMTrans proposed | MAE | 4.15 mm | Ejection Fraction Estimation · split: test · video-setting=single-video A4C/AP4 | GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular DiagnosisSource quoteL132: 4.15 |
| 2023 | UCVME proposed | MAE | 4.37 | Ejection Fraction Estimation · semi-supervised · labeled-data=25% | Semi-Supervised Deep Regression with Uncertainty Consistency and Variational Model Ensembling via Bayesian Neural NetworksSource quoteL441: Our method consistently achieves the best results for all settings by significant margins. We are also able to achieve an MAE of 4.37 using a quarter of the labels, which is only a relative 5.8% higher than the 4.13 MAE achieved by Ouyang et al. on fully labeled data. Our proposed method therefore reduces the number of labels required for training which is highly valuable for medical regression tasks. |
| 2023 | Thomas et al. [24] baseline | MAE | 4.23 mm | Ejection Fraction Estimation · split: test · video-setting=single-video A4C/AP4 | GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular DiagnosisSource quoteL122: 4.23 |
| 2022 | EchoCoTr proposed | MAE | 3.95 | Ejection Fraction Estimation · modality=echocardiography video | EchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal EchocardiographySource quoteL4: Learning spatiotemporal features is an important task for efficient video understanding especially in medical images such as echocardiograms. Convolutional neural networks (CNNs) and more recent vision transformers (ViTs) are the most commonly used methods with limitations per each. CNNs are good at capturing local context but fail to learn global information across video frames. On the other hand, vision transformers can incorporate global details and long sequences but are computationally expensive and typically require more data to train. In this paper, we propose a method that addresses the limitations we typically face when training on medical video data such as echocardiographic scans. The algorithm we propose (EchoCoTr) utilizes the strength of vision transformers and CNNs to tackle the problem of estimating the left ventricular ejection fraction (LVEF) on ultrasound videos. We demonstrate how the proposed method outperforms state-of-the-art work to-date on the EchoNet-Dynamic dataset with MAE of 3.95 and R^2 of 0.82. These results show noticeable improvement compared to all published research. In addition, we show extensive ablations and comparisons with several algorithms, including ViT and BERT. The code is available |
| 2022 | EchoCoTr proposed | R^2 | 0.82 | Ejection Fraction Estimation · modality=echocardiography video | EchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal EchocardiographySource quoteL4: Learning spatiotemporal features is an important task for efficient video understanding especially in medical images such as echocardiograms. Convolutional neural networks (CNNs) and more recent vision transformers (ViTs) are the most commonly used methods with limitations per each. CNNs are good at capturing local context but fail to learn global information across video frames. On the other hand, vision transformers can incorporate global details and long sequences but are computationally expensive and typically require more data to train. In this paper, we propose a method that addresses the limitations we typically face when training on medical video data such as echocardiographic scans. The algorithm we propose (EchoCoTr) utilizes the strength of vision transformers and CNNs to tackle the problem of estimating the left ventricular ejection fraction (LVEF) on ultrasound videos. We demonstrate how the proposed method outperforms state-of-the-art work to-date on the EchoNet-Dynamic dataset with MAE of 3.95 and R^2 of 0.82. These results show noticeable improvement compared to all published research. In addition, we show extensive ablations and comparisons with several algorithms, including ViT and BERT. The code is available |
| 2022 | EchoGNN proposed | MAE | 4.45 | Ejection Fraction Estimation | EchoGNN: Explainable Ejection Fraction Estimation with Graph Neural NetworksSource quoteL142: 0.76 4.45 |
| 2022 | Bayesian [12] baseline | MAE | 4.46 | Ejection Fraction Estimation | EchoGNN: Explainable Ejection Fraction Estimation with Graph Neural NetworksSource quoteL136: 0.75 4.46 |
| 2021 | UVT (M., mirror video sampling) proposed non-standard slice | MAE | 5.95 | Ejection Fraction Estimation · video-sampling=mirror | Ultrasound Video Transformers for Cardiac Ejection Fraction EstimationSource quoteL114: M. (ours) │ 5.32 (4.90) │ 7.23 │ 0.64 │ 5.95 (5.90) │ 8.38 │ 0.52 |