EchoNet-Dynamic · Image Segmentation

32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Image Segmentation: proposed/measured results on test (including papers where test split is standard/implicit).

3.73.83.93.9202420252026CoReEcho: 3.9 (2024)MCSDR (vision-only): 3.76 (2026)
Click any point on the timeline to inspect method, protocol, and paper.
#MethodScore ↓YearProtocol / SettingsPaper & Evidence
1MCSDR (vision-only) SOTA frontier3.762026-02-01Test set; evaluated in vision-only mode to avoid label leakage from derived text attr…Generative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video
Source quote
Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89).
2CoReEcho SOTA frontier3.92024-01-01EF regression; predictions from three sampled clips averaged for each video.CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis
Source quote
Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.}
Other primary task on EchoNet-Dynamic: Image Segmentation · mDice ↑ (2 papers)
#MethodScore ↑YearProtocol / SettingsPaper & Evidence
1SAMUS SOTA frontier91.792024-01-01EchoNet-Dynamic videos have labels only for end-systolic and end-diastolic phases; ev…MemSAM: Taming Segment Anything Model for Echocardiography Video Segmentation
Source quote
91.79
2EchoONE88.362025-01-01training=not used · evaluation=external · External evaluation; EchoNet-Dynamic was not used for training.EchoONE: Segmenting Multiple Echocardiography Planes in One Model
Source quote
EchoONE │ 73.94 │ 59.31 │ 88.36 │ 79.65