# EchoNet-Dynamic (`echonet-dynamic`)

- **Canonical ID**: `bmk_c39f97d72f911f87`
- **Task**: image-segmentation · **Modality**: vision
- **Coverage**: 32 papers · 84 observations
- **Tasks Evaluated**: Image Segmentation (`?task=image-segmentation`, 11 papers), Ejection Fraction Estimation (`?task=ejection-fraction-estimation`, 7 papers), Ejection Fraction Regression (`?task=ejection-fraction-regression`, 2 papers), Image Generation (`?task=image-generation`, 2 papers), Video Generation (`?task=video-generation`, 2 papers), Binary Classification (`?task=binary-classification`, 1 papers), Cardiac Function Estimation (`?task=cardiac-function-estimation`, 1 papers), Classification (`?task=classification`, 1 papers)

## Comparable Cohort Leaderboards

### Image Segmentation · MAE ↓ · test (2 papers)

| # | Method | Score | Year | Settings | Paper |
| ---: | --- | ---: | --- | --- | --- |
| 1 | MCSDR (vision-only) | 3.76 | 2026-02-01 | - | [Generative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video](/work/generative-regression-for-left-ventricular-ejection-fraction) |
| 2 | CoReEcho | 3.9 | 2024-01-01 | - | [CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis](/work/coreecho-continuous-representation-learning-for-2d-time) |

### Image Segmentation · mDice ↑ (2 papers)

| # | Method | Score | Year | Settings | Paper |
| ---: | --- | ---: | --- | --- | --- |
| 1 | SAMUS | 91.79 | 2024-01-01 | - | [MemSAM: Taming Segment Anything Model for Echocardiography Video Segmentation](/work/memsam-taming-segment-anything-model-for-echocardiography) |
| 2 | EchoONE | 88.36 | 2025-01-01 | training=not used, evaluation=external | [EchoONE: Segmenting Multiple Echocardiography Planes in One Model](/work/echoone-segmenting-multiple-echocardiography-planes-in-one-cd28) |

## Recent Extracted Observations

| Year | Method | Role | Metric | Score | Split | Regime | Paper | Verbatim Quote |
| --- | --- | --- | --- | ---: | --- | --- | --- | --- |
| 2026 | Single-parameter latent orbit features with supervised MLP prediction head | proposed | EF MAE | 6.02% % | - | - | [Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits](/work/self-supervised-cardiac-phase-detection-via-single-parameter) | We compare our approach with LMP~\cite{yangLatentMotionProfiling2026} by training an equivalent MLP head using the concatenation of its structure and motion fea |
| 2026 | MCSDR (vision-only) | unclear | MAE | 3.76 | test | - | [Generative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video](/work/generative-regression-for-left-ventricular-ejection-fraction) | Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model Pa |
| 2026 | LMP features with an equivalent supervised MLP prediction head | unclear | EF MAE | 6.27% % | - | - | [Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits](/work/self-supervised-cardiac-phase-detection-via-single-parameter) | We compare our approach with LMP~\cite{yangLatentMotionProfiling2026} by training an equivalent MLP head using the concatenation of its structure and motion fea |
| 2026 | PanEcho | baseline | MAE | 5.35 | test | - | [Generative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video](/work/generative-regression-for-left-ventricular-ejection-fraction) | Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model Pa |
| 2025 | EchoVLM | proposed | Dice similarity coefficient (DSC) | 93.1% % | - | - | [EchoVLM: Measurement-Grounded Multimodal Learning for Echocardiography](/work/echovlm-measurement-grounded-multimodal-learning) | EchoVLM outperforms tasks-specialists and achieves similar performance as vision FM. EchoVLM attains the best DSC on EchoNet-Dynamic (93.1%) and EchoNet-Pediatr |
| 2025 | HSS-Net (full method) | proposed | Dice | 92.67 | - | - | [Hierarchical Spatio-Temporal Segmentation Network for Ejection Fraction Estimation in Echocardiography Videos](/work/hierarchical-spatio-temporal-segmentation-network) | HSS-Net~(Ours) & \textBF{90.47} & \textBF{2.43±5.02} & \textBF{93.89} & \textBF{11.29} & \textBF{84.50} & \textBF{0.95±6.75} & \textBF{92.67} & \textBF{2.66} |
| 2024 | Adaptive (w/ aug & LD) | proposed | Dice score (LV) | 0.910 | test | - | [Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling](/work/label-dropout-improved-deep-learning-echocardiography) | Adaptive (w/ aug \& LD)& 0.910& 0.518& 0.689 |
| 2024 | Adaptive (w/ aug & LD) | proposed | Dice score (LVM) | 0.518 | test | - | [Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling](/work/label-dropout-improved-deep-learning-echocardiography) | Adaptive (w/ aug \& LD)& 0.910& 0.518& 0.689 |
| 2024 | Adaptive (w/ aug & LD) | proposed | Dice score (LA) | 0.689 | test | - | [Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling](/work/label-dropout-improved-deep-learning-echocardiography) | Adaptive (w/ aug \& LD)& 0.910& 0.518& 0.689 |
| 2024 | CoReEcho | proposed | MAE | 3.90 | - | - | [CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis](/work/coreecho-continuous-representation-learning-for-2d-time) | Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020vi |
| 2024 | CoReEcho | proposed | R2 | 82.44 | - | - | [CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis](/work/coreecho-continuous-representation-learning-for-2d-time) | Deep learning (DL) models have been advancing automatic medical image analysis on various modalities, including echocardiography, by offering a comprehensive en |
| 2024 | CoReEcho | proposed | RMSE | 5.13 | - | - | [CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis](/work/coreecho-continuous-representation-learning-for-2d-time) | Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020vi |
| 2024 | EchoONE | proposed | mDice | 88.36 | - | - | [EchoONE: Segmenting Multiple Echocardiography Planes in One Model](/work/echoone-segmenting-multiple-echocardiography-planes-in-one-cd28) | EchoONE & 73.94 & 59.31 & 88.36 & 79.65 |
| 2024 | Adaptive (w/ aug) | ablation | Dice score (LV) | 0.892 | test | - | [Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling](/work/label-dropout-improved-deep-learning-echocardiography) | Adaptive (w/ aug)& 0.892& 0.319& 0.553 |
| 2024 | Adaptive (w/ aug) | ablation | Dice score (LVM) | 0.319 | test | - | [Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling](/work/label-dropout-improved-deep-learning-echocardiography) | Adaptive (w/ aug)& 0.892& 0.319& 0.553 |
| 2024 | Adaptive (w/ aug) | ablation | Dice score (LA) | 0.553 | test | - | [Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling](/work/label-dropout-improved-deep-learning-echocardiography) | Adaptive (w/ aug)& 0.892& 0.319& 0.553 |
| 2024 | SAMUS | unclear | mDice | 91.79 | - | - | [MemSAM: Taming Segment Anything Model for Echocardiography Video Segmentation](/work/memsam-taming-segment-anything-model-for-echocardiography) | 91.79 |
| 2023 | filter-pruned DeepLabV3 | proposed | compression rate | 1148x × | - | compressed | [Sculpting Efficiency: Pruning Medical Imaging Models for On-Device Inference](/work/sculpting-efficiency-pruning-medical-imaging-models) | In Figure \ref{fig:results}, globally weight-pruned models exhibit impeccable resiliency, maintaining quality within 1% of the baseline even at a sparsity of 98 |
| 2023 | EchoAI | unclear | mean absolute error | 4.34 | - | fine-tuned | [Echocardiogram Foundation Model - Application 1: Estimating Ejection Fraction](/work/echocardiogram-foundation-model-application-1-estimating) | In this work, we introduce EchoAI, a foundation model for echocardiograms. We train EchoAI on a comprehensive dataset comprising 1.5 million echocardiograms. Th |
| 2023 | EchoAI | unclear | mean absolute percentage error | 9.40% % | - | fine-tuned | [Echocardiogram Foundation Model - Application 1: Estimating Ejection Fraction](/work/echocardiogram-foundation-model-application-1-estimating) | Cardiovascular diseases stand as the primary global cause of mortality. Among the various imaging techniques available for visualising the heart and evaluating  |
| 2022 | SimCLR-pretrained DeepLabV3 | proposed | Dice score | 0.9252 | - | - | [Contrastive Pretraining for Echocardiography Segmentation with Limited Data](/work/contrastive-pretraining-for-echocardiography-segmentation-jx4k) | 3 & SimCLR & DeepLabV3 & 0.9252 (0.0476) & 0.9242 (0.0452) & 0.9190 (0.0509) & 0.9125 (0.0548) |
| 2022 | SimCLR-pretrained DeepLabV3 | proposed | Dice score | 0.9125 | - | fine-tuned | [Contrastive Pretraining for Echocardiography Segmentation with Limited Data](/work/contrastive-pretraining-for-echocardiography-segmentation-jx4k) | As Table \ref{tab:echo} shows, our proposed self supervised method which uses DeepLabV3 with a SimCLR pretrained backbone outperformed all other methods (includ |
| 2022 | DeepLabV3 (Ouyang et al.) | baseline | Dice score | 0.9211 | - | - | [Contrastive Pretraining for Echocardiography Segmentation with Limited Data](/work/contrastive-pretraining-for-echocardiography-segmentation-jx4k) | Furthermore, \cite{ouyang2020video} attempted the same task, training on their large publicly available EchoNet-Dynamic dataset \cite{ouyang2019echonet}, contai |
| 2022 | Fully supervised training | baseline | Dice score | 0.9229 | - | - | [Contrastive Pretraining for Echocardiography Segmentation with Limited Data](/work/contrastive-pretraining-for-echocardiography-segmentation-jx4k) | As Table \ref{tab:echo} shows, our proposed self supervised method which uses DeepLabV3 with a SimCLR pretrained backbone outperformed all other methods (includ |
