EchoNet-Dynamic

32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Ejection Fraction Estimation.

3.94.14.34.520222023EchoCoTr: 3.95 (2022)EchoGNN: 4.45 (2022)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 84 of 84 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Single-parameter latent orbit features with supervised MLP prediction head proposedEF MAE6.02%Image SegmentationSelf-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits
Source quote
L143: We compare our approach with LMP~\cite{yangLatentMotionProfiling2026} by training an equivalent MLP head using the concatenation of its structure and motion features. Our method yields improved EF prediction performance (6.02% MAE vs.\ 6.27% MAE) with one-tenth as many pre-training epochs, indicating that the proposed cyclic prior provides a strong inductive bias for capturing motion cues relevant to cardiac function assessment. Fully supervised methods (e.g., \cite{maani2024coreecho}) act as an upper bound.
2026MCSDR (vision-only)MAE3.76Image Segmentation · split: testGenerative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video
Source quote
L191: Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89).
2026LMP features with an equivalent supervised MLP prediction headEF MAE6.27%Image SegmentationSelf-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits
Source quote
L143: We compare our approach with LMP~\cite{yangLatentMotionProfiling2026} by training an equivalent MLP head using the concatenation of its structure and motion features. Our method yields improved EF prediction performance (6.02% MAE vs.\ 6.27% MAE) with one-tenth as many pre-training epochs, indicating that the proposed cyclic prior provides a strong inductive bias for capturing motion cues relevant to cardiac function assessment. Fully supervised methods (e.g., \cite{maani2024coreecho}) act as an upper bound.
2026PanEcho baselineMAE5.35Image Segmentation · split: testGenerative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video
Source quote
L191: Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89).
2025EchoVLM proposedDice similarity coefficient (DSC)93.1%Image Segmentation · view=A4CEchoVLM: Measurement-Grounded Multimodal Learning for Echocardiography
Source quote
L134: EchoVLM outperforms tasks-specialists and achieves similar performance as vision FM. EchoVLM attains the best DSC on EchoNet-Dynamic (93.1%) and EchoNet-Pediatric-A4C (92.4%), and ties EchoApex on EchoNet-Pediatric-PSAX (93.0%) (Table \ref{tab: seg}). On the CAMUS dataset, EchoVLM matches EchoApex for left ventricular segmentation (93.8%) and achieves competitive performance for left atrial segmentation (90.2%). Visualization of segmentation results on CAMUS using EchoVLM is shown in Figure \ref{fig:camus1}. These results indicate that our pretraining maintains transferable local features for segmentation across datasets.
2025Ours (Temporal, End-to-end, Oracle) proposed non-standard sliceAUROC0.88Binary Classification · resolution=32×32 · frames=10 · setting=oracleTemporal Representation Learning for Real-Time Ultrasound Analysis
Source quote
L169: Ours (Temporal, End-to-end, Oracle) │ \sim10,000 │ \sim8M │ 10×32×32 │ 0.89 │ 0.84 │ 0.88
2025Ours (Temporal, End-to-end, Oracle) proposed non-standard sliceF10.89Binary Classification · resolution=32×32 · frames=10 · setting=oracleTemporal Representation Learning for Real-Time Ultrasound Analysis
Source quote
L169: Ours (Temporal, End-to-end, Oracle) │ \sim10,000 │ \sim8M │ 10×32×32 │ 0.89 │ 0.84 │ 0.88
2025Ours (Temporal, End-to-end, Oracle) proposed non-standard sliceAccuracy0.84Binary Classification · resolution=32×32 · frames=10 · setting=oracleTemporal Representation Learning for Real-Time Ultrasound Analysis
Source quote
L169: Ours (Temporal, End-to-end, Oracle) │ \sim10,000 │ \sim8M │ 10×32×32 │ 0.89 │ 0.84 │ 0.88
2025TPA (GNN temporal extractor) proposedmacro F158.62%Classification · variant=TPA with GNN temporal extractor · class-count=3TPA: Temporal Prompt Alignment for Fetal Congenital Heart Defect Classification
Source quote
L415: GNN │ \bfseries 84.84 │ \bfseries 87.69 │ \bfseries 58.62 │ \bfseries 82.11
2025LD-ViCE-SG proposedInference time23 sVideo Counterfactual Explanation · split: val · T=15 · gpu=NVIDIA A100 · variant=SG · lambda_c=0.15LD-ViCE: Latent Diffusion Model for Video Counterfactual Explanations
Source quote
L269: SG │ 23 s │ 0.99 │ 0.50 │ 1.02 │ 0.75 │ 0.17
2025LD-ViCE-SGA proposedLPIPS0.13Video Counterfactual Explanation · split: val · variant=SGA · metric_aggregation=per-frame LPIPS averaged across video frames · artifact_suppression_threshold=0.03LD-ViCE: Latent Diffusion Model for Video Counterfactual Explanations
Source quote
L270: SGA │ 24 s │ 0.90 │ 2.78 │ 3.75 │ 0.84 │ 0.13
2025HSS-Net (full method) proposedcorr (Pearson correlation for EF estimation)84.50Ejection Fraction EstimationHierarchical Spatio-Temporal Segmentation Network for Ejection Fraction Estimation in Echocardiography Videos
Source quote
L159: HSS-Net~(Ours) │ \textBF{90.47} │ \textBF{2.43±5.02} │ \textBF{93.89} │ \textBF{11.29} │ \textBF{84.50} │ \textBF{0.95±6.75} │ \textBF{92.67} │ \textBF{2.66}
2025HSS-Net (full method) proposedDice92.67Image SegmentationHierarchical Spatio-Temporal Segmentation Network for Ejection Fraction Estimation in Echocardiography Videos
Source quote
L159: HSS-Net~(Ours) │ \textBF{90.47} │ \textBF{2.43±5.02} │ \textBF{93.89} │ \textBF{11.29} │ \textBF{84.50} │ \textBF{0.95±6.75} │ \textBF{92.67} │ \textBF{2.66}
2025EchoGPT proposedAUC (40%)0.9519Left Ventricular Ejection Fraction Prediction · split: testEchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram Videos
Source quote
L244: Specifically, EchoGPT achieved AUC values of 0.9519,
2025EchoGPT proposedAUC (50%)0.9221Left Ventricular Ejection Fraction Prediction · split: testEchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram Videos
Source quote
L245: 0.9221, and 0.8475 for the thresholds of 40%, 50%, and
2025EchoGPT proposedAUC (70%)0.8475Left Ventricular Ejection Fraction Prediction · split: testEchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram Videos
Source quote
L245: 0.9221, and 0.8475 for the thresholds of 40%, 50%, and
2025EchoGPT proposedR²0.6848Left Ventricular Ejection Fraction Prediction · split: testEchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram Videos
Source quote
L247: 50%, and above 70%. In terms of the R² score, EchoGPT reached 0.6848, implying that our model accounts for approximately 68.48% of the variability in ejection fraction, the highest proportion among all compared models. Furthermore, EchoGPT’s mean absolute error (MAE) was 7.5934, the lowest among all models, which further corroborates the high precision of EchoGPT in predicting left ventricular ejection fraction. In comparison, other models such as EchoCLIP,
2025EchoGPT proposedMAE (Mean Absolute Error)7.5934Left Ventricular Ejection Fraction Prediction · split: testEchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram Videos
Source quote
L247: 50%, and above 70%. In terms of the R² score, EchoGPT reached 0.6848, implying that our model accounts for approximately 68.48% of the variability in ejection fraction, the highest proportion among all compared models. Furthermore, EchoGPT’s mean absolute error (MAE) was 7.5934, the lowest among all models, which further corroborates the high precision of EchoGPT in predicting left ventricular ejection fraction. In comparison, other models such as EchoCLIP,
2025Single-Input Fusion proposedRMSE7.02Ejection Fraction Estimation · split: test · architecture=Single-Input FusionInvestigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography Videos
Source quote
L285: Layer Normalization. More pronounced gains were observed with the Single-Input and Dual-Input Fusion architectures, which achieved test RMSE values of 7.02 and 7.64, respectively, both when paired with
2025Dual-Input Fusion proposedRMSE7.64Ejection Fraction Estimation · split: test · architecture=Dual-Input FusionInvestigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography Videos
Source quote
L285: Layer Normalization. More pronounced gains were observed with the Single-Input and Dual-Input Fusion architectures, which achieved test RMSE values of 7.02 and 7.64, respectively, both when paired with
2025MCDM (ReID+Flow) proposedFID↓47.1Image Generation · variant=ReID+Flow · video-length=64-framesLabel-free Motion-Conditioned Diffusion Model for Cardiac Ultrasound Synthesis
Source quote
L134: motion │ \(×\) │ MCDM (ReID+Flow) │ 47.1 │ 225.1 │ -- │ \textbf{2.19-± 0.06}
2025VidFuncta only φ ablationMAE6.11Ejection Fraction Prediction · split: test · evaluation=5-foldVidFuncta: Towards Generalizable Neural Representations for Ultrasound Videos
Source quote
L160: VidFuncta only \phi │ 6.11 │ 8.35 │ 0.56 │ 62.5 │ 70.3 │ 65.6 │ 64.6 │ 68.1 │ 63.0
2025I3D-mini (B2) ablationRMSE6.7954Ejection Fraction Estimation · variant=B2 · architecture=I3D-mini · conv2-kernel=3×3×3Investigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography Videos
Source quote
L169: 6.7954
2025I3D-mini (B1) ablationRMSE7.0906Ejection Fraction Estimation · variant=B1 · architecture=I3D-mini · conv2-kernel=1×1×1Investigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography Videos
Source quote
L165: 7.0906
2025ECHO-VISION-FM baselineAccuracy0.89Binary Classification · fine-tuned · backbone=ViT-B · resolution=224×224 · frames=16 · pretraining-data=40% of MIMIC-IV-ECHOTemporal Representation Learning for Real-Time Ultrasound Analysis
Source quote
L168: ECHO-VISION-FM │ \sim200,000 │ \sim98M │ 16×224×224 │ 0.93 │ 0.89 │ 0.93
2025PocovidNet on 𝒱 baselineMAE4.34Ejection Fraction Prediction · split: test · input=original video · evaluation=5-foldVidFuncta: Towards Generalizable Neural Representations for Ultrasound Videos
Source quote
L169: PocovidNet on \mathcal{V} │ 4.34 │ 5.84 │ 0.77 │ 86.7 │ 88.2 │ 93.1 │ 76.1 │ 80.1 │ 82.3
2025R23 (average) baselineInference time42 sVideo Counterfactual Explanation · split: val · gpu=NVIDIA A100 · method=R23 average · comparison_variant=1SCM · counterfactuals_per_input=3LD-ViCE: Latent Diffusion Model for Video Counterfactual Explanations
Source quote
L266: R23 │ 42 s │ 0.31 │ 7.89 │ 9.74 │ 0.52 │ 0.22
2025R23* (best) baselineLPIPS0.21Video Counterfactual Explanation · split: val · method=R23 best of 3 · target=derived from predicted value · comparison_variant=1SCM · metric_aggregation=per-frame LPIPS averaged across video framesLD-ViCE: Latent Diffusion Model for Video Counterfactual Explanations
Source quote
L267: R23* │ 126 s │ 0.71 │ 4.68 │ 6.31 │ 0.53 │ 0.21
2025PanEcho baselineLV EF MAE5.79Regression · split: test · 0-shotCardioBench: Do Echocardiography Foundation Models Generalize Beyond the Lab?
Source quote
L77: PanEcho \cite{holste2025panecho} {\textcolor{customblue}{\scalebox{0.6}{\ding{108}}}} │ 5.79 │ 11.63 │ 9.10 │ 0.36 │ 0.21 │ 0.18 │ 58.90 │ 30.50 │ 24.30 │ 20.52
2025motion baseline baselineFID↓48.8Image Generation · training=from-scratch · video-length=64-framesLabel-free Motion-Conditioned Diffusion Model for Cardiac Ultrasound Synthesis
Source quote
L132: motion │ \(×\) │ baseline │ 48.8 │ 244.2 │ -- │ 2.15-± 0.06
2024Adaptive (w/ aug & LD) proposed non-standard sliceDice score (LV)0.910Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689
2024Adaptive (w/ aug & LD) proposed non-standard sliceDice score (LVM)0.518Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689
2024Adaptive (w/ aug & LD) proposed non-standard sliceDice score (LA)0.689Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689
2024CoReEcho proposedMAE3.90Image SegmentationCoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis
Source quote
L189: Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.}
2024CoReEcho proposedR282.44Image SegmentationCoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis
Source quote
L4: Deep learning (DL) models have been advancing automatic medical image analysis on various modalities, including echocardiography, by offering a comprehensive end-to-end training pipeline. This approach enables DL models to regress ejection fraction (EF) directly from 2D+time echocardiograms, resulting in superior performance. However, the end-to-end training pipeline makes the learned representations less explainable. The representations may also fail to capture the continuous relation among echocardiogram clips, indicating the existence of spurious correlations, which can negatively affect the generalization. To mitigate this issue, we propose \texttt{CoReEcho}{}, a novel training framework emphasizing continuous representations tailored for direct EF regression. Our extensive experiments demonstrate that \texttt{CoReEcho}{}: 1) outperforms the current state-of-the-art (SOTA) on the largest echocardiography dataset (EchoNet-Dynamic) with MAE of 3.90 \ │ R2 of 82.44, and 2) provides robust and generalizable features that transfer more effectively in related downstream tasks. The code is publicly available at \url{https://github.com/BioMedIA-MBZUAI/CoReEcho}.
2024CoReEcho proposedRMSE5.13Image SegmentationCoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis
Source quote
L189: Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.}
2024EchoONE proposedmDice88.36Image Segmentation · training=not used · evaluation=externalEchoONE: Segmenting Multiple Echocardiography Planes in One Model
Source quote
L256: EchoONE │ 73.94 │ 59.31 │ 88.36 │ 79.65
2024ECM proposedSSIM0.611Video Generation · condition=IF/Motion CurvesExplainable and Controllable Motion Curve Guided Cardiac Ultrasound Video Generation
Source quote
L158: \textcolor{blue}{0.611}
2024ECM proposedLpips0.118Video Generation · condition=IF/Motion CurvesExplainable and Controllable Motion Curve Guided Cardiac Ultrasound Video Generation
Source quote
L162: \textcolor{blue}{0.118}
2024EchoNet-Synthetic LVDM (Dynamic) proposedSampling time2.4sVideo GenerationEchoNet-Synthetic: Privacy-preserving Video Generation for Safe Medical Data Sharing
Source quote
L234: \gls{dyn} │ 17.4 │ 71.4 │ 168.3 │ 2.31_{±{0.08}} │ 28.8 │ 103.5 │ 280.2 │ 2.26_{±{0.08}} │ 2.4s
2024Adaptive (w/ aug) ablation non-standard sliceDice score (LV)0.892Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=not usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L116: Adaptive (w/ aug) │ 0.892 │ 0.319 │ 0.553
2024Adaptive (w/ aug) ablation non-standard sliceDice score (LVM)0.319Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=not usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L116: Adaptive (w/ aug) │ 0.892 │ 0.319 │ 0.553
2024Adaptive (w/ aug) ablation non-standard sliceDice score (LA)0.553Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=not usedLabel Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling
Source quote
L116: Adaptive (w/ aug) │ 0.892 │ 0.319 │ 0.553
2024SAMUSmDice91.79Image SegmentationMemSAM: Taming Segment Anything Model for Echocardiography Video Segmentation
Source quote
L187: 91.79
2024EchoDiffusion baselineSSIM0.530Video Generation · condition=IF/LVEFExplainable and Controllable Motion Curve Guided Cardiac Ultrasound Video Generation
Source quote
L155: EchoDiffusion \cite{reynaud2023feature} │ IF/LVEF │ 0.530 │ 9.650 │ \textcolor{blue}{12.30} │ 0.210 │ \textcolor{blue}{60.50}
2024EchoDiffusion baselineLpips0.210Video Generation · condition=IF/LVEFExplainable and Controllable Motion Curve Guided Cardiac Ultrasound Video Generation
Source quote
L155: EchoDiffusion \cite{reynaud2023feature} │ IF/LVEF │ 0.530 │ 9.650 │ \textcolor{blue}{12.30} │ 0.210 │ \textcolor{blue}{60.50}
2024EchoDiffusion (EchoDiff.) baselineSampling time279sVideo GenerationEchoNet-Synthetic: Privacy-preserving Video Generation for Safe Medical Data Sharing
Source quote
L233: EchoDiff.\cite{reynaud2023feature} │ 24.0 │ 228 │ 2.59_{±{0.06}} │ 28.0 │ 294.4 │ 2.47_{±{0.04}} │ 279s
2024EchoDiffusion (EchoDiff.) baselineR20.55Ejection Fraction RegressionEchoNet-Synthetic: Privacy-preserving Video Generation for Safe Medical Data Sharing
Source quote
L275: EchoDiff.~\cite{reynaud2023feature} │ 0.55 │ 6.02 │ 8.21
2023filter-pruned DeepLabV3 proposedcompression rate1148x ×Image Segmentation · compressed · params=34.5K · pruning-rate=98.4%Sculpting Efficiency: Pruning Medical Imaging Models for On-Device Inference
Source quote
L35: In Figure \ref{fig:results}, globally weight-pruned models exhibit impeccable resiliency, maintaining quality within 1% of the baseline even at a sparsity of 98.4% (633K params.). On the contrary, a local strategy (not depicted) deteriorates model quality at high targets \cite{blalock2020state}; some layers are more sensitive than others. Our filter pruning results corroborate the overarching observation that DeepLabV3 is substantially overparameterized for this task. Specifically, the most extreme case, with 98.4% filters pruned, yields DICE scores within 4% of the baseline while being 1148x smaller (34.5K params.). Moreover, the optimal filter pruned model (0.875) deviates from the baseline by only 0.7% while offering 7.5x higher throughput at 233 FPS, making it more than viable for real-time use. This model is just as fast on a CPU as the GPU baseline, a profound improvement that results solely from pruning.
2023SupReMix proposedMAE4.02%Cardiac Function Estimation · split: test · linear-probe · pretraining-epochs=200 · linear-probe-epochs=100SupReMix: Supervised contrastive learning for medical imaging regression with mixup
Source quote
L228: We compare SupReMix against both classification-based (SimCLR \citep{chen2019self}, SupCon \citep{khosla2020supervised}) and regression-based (AdaCon \citep{dai2021adaptive}, RnC \citep{zha2023rank}) representation learning methods across six medical imaging regression datasets spanning different modalities (MRI, X-ray, ultrasound, and PET). As shown in Figure \ref{fig:mae_comparision}, SupReMix consistently achieves lower MAE than all baseline methods. Taking bone age prediction on RSNA as an example, SupReMix reduces the MAE to 4.08 months compared to the classification-based method SupCon (6.79 months). The performance gains are particularly notable in challenging tasks such as cardiac function estimation, where SupReMix achieves an MAE of 4.02 compared to SupCon's 5.88. Moreover, we observe that SupReMix consistently outperforms vanilla regression (shown in dashed line). Additional performance metrics including Mean Squared Error (MSE), correlation coefficient (\rho), and Geometric Mean (GM) error are provided in Tables \ref{table1}, \ref{table2}, \ref{table3}, \ref{table4}, \ref{table5}, \ref{table6}.
2023GEMTrans proposedMAE4.15 mmEjection Fraction Estimation · split: test · video-setting=single-video A4C/AP4GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular Diagnosis
Source quote
L132: 4.15
2023UCVME proposedMAE4.37Ejection Fraction Estimation · semi-supervised · labeled-data=25%Semi-Supervised Deep Regression with Uncertainty Consistency and Variational Model Ensembling via Bayesian Neural Networks
Source quote
L441: Our method consistently achieves the best results for all settings by significant margins. We are also able to achieve an MAE of 4.37 using a quarter of the labels, which is only a relative 5.8% higher than the 4.13 MAE achieved by Ouyang et al. on fully labeled data. Our proposed method therefore reduces the number of labels required for training which is highly valuable for medical regression tasks.
2023SimLVSeg-3D proposedoverall DSC93.32%Video Segmentation · split: test · frames=32UniLVSeg: Unified Left Ventricular Segmentation with Sparsely Annotated Echocardiogram Videos through Self-Supervised Temporal Masking and Weakly Supervised Training
Source quote
L123: \texttt{SimLVSeg}{} outperforms recent state-of-the-art approaches (\cite{ouyang2020video, Isensee2021-yh, weak_supervision}) on the EchoNet test set, as shown in Table \ref{tab_main} and Figure \ref{fig_comparisons}. We compare our method with the approach proposed by the EchoNet dataset publisher \cite{ouyang2020video}, the famous nnU-Net \cite{Isensee2021-yh}, which can perform better than specially designed echocardiography networks as mentioned in \cite{sarina_lightweight}, and the method achieving the highest dice similarity coefficient (DSC) on the test set \cite{weak_supervision}. \texttt{SimLVSeg}{} with 3D U-Net (\texttt{SimLVSeg}{}-3D) results in 93.32% overall DSC, and \texttt{SimLVSeg}{}-SI approach shows on-par performance. Confidence interval (CI) analysis further shows no overlap between the 95% CI of \texttt{SimLVSeg}{} with other state-of-the-art solutions, indicating that our improvements hold statistical significance over those methods with a p-value of less than 0.05. The \texttt{SimLVSeg}{}-3D was trained with 32 frames sampled consecutively, while the \texttt{SimLVSeg}{}-SI was trained with 16 frames sampled at every 5\textsuperscript{th} frame. This experiment shows that a video segmentation network trained in a weakly-supervised manner is capable of segmenting the LV with a 3.8x lower computational cost compared to \cite{weak_supervision}.
2023SimLVSeg-SI with SSL temporal-masking pre-training proposedoverall DSC93.31%Video Segmentation · variant=with SSL temporal-masking pre-trainingUniLVSeg: Unified Left Ventricular Segmentation with Sparsely Annotated Echocardiogram Videos through Self-Supervised Temporal Masking and Weakly Supervised Training
Source quote
L189: We observed that randomly masking a significant portion (60%) of an echocardiogram clip during SSL pre-training results in the best performance. The masking SSL improves the overall DSC of the SI approach from 93.19% to 93.31%, as reported in Figure \ref{fig_ssl}. Further, as shown in Fig. \ref{fig:discussion}, we observe that self-supervision with temporal masking enables the network to maintain better temporal consistency across predictions in a given echocardiogram clip. Fig. \ref{fig:discussion_segmentation} demonstrates that a video segmentation model pre-trained with self-supervised temporal masking is more resilient to noise and missing artifacts. The pre-training stage also alleviates the over-segmentation and temporal inconsistency issues that are commonly encountered in echocardiography caused by unclear (or, even worse, invisible) boundaries. Also, the SSL pre-trained model achieves a smoother LV segmentation area prediction with significantly less rapid fluctuations (see Fig. \ref{fig:discussion_lv_area}), indicating better temporal consistency. We further investigate the phenomenon in the frequency domain by applying the Fast Fourier Transform (FFT) to the predicted signals (LV area) as depicted in Fig. \ref{fig:discussion_freq_comp}. We observe that SSL pre-training results in a lower magnitude of the high-frequency components, which are typically the result of noise and rapid fluctuation. Based on these observations, we hypothesize that the pre-training stage helps the 3D U-Net model to better learn the semantic features that are useful for estimating human heart structures in the A4C view, resulting in a more robust prediction. Additionally, Table \ref{tab_ood} showcases the significant impact of the SSL pre-training stage when testing with samples subject to distribution shifts, indicating that the SSL pre-training enhances the model's generalization capability. These findings indicate that pre-training with self-supervision remarkably benefits the downstream LV segmentation task. Hence, self-supervised learning with vast echocardiogram videos can be a promising solution to provide strong pre-trained models that can generalize well in downstream echocardiography-related clinical tasks.
2023SimLVSeg-SI with MobileNetV3 backbone proposedoverall DSC93.16%Video Segmentation · backbone=MobileNetV3 · params=6.69MUniLVSeg: Unified Left Ventricular Segmentation with Sparsely Annotated Echocardiogram Videos through Self-Supervised Temporal Masking and Weakly Supervised Training
Source quote
L191: We have shown that both the SI and 3D segmentation networks trained using our proposed \texttt{SimLVSeg}{} are capable of accurately segmenting the left ventricle in echocardiogram videos. Both \texttt{SimLVSeg}{}-3D and \texttt{SimLVSeg}{}-SI outperform the state-of-the-art \cite{weak_supervision}, suggesting that the superior performance can be attributed to the \texttt{SimLVSeg}{} design rather than the selection of the underlying network architectures. The 3D U-Net performance is slightly better than the SI network with the UniFormer-S backbone. However, designing a backbone for 3D U-Net is not straightforward since it requires tedious hyperparameter tuning. On the other hand, there are plenty of optimized models that can be utilized as a backbone for the SI approach. For instance, MobileNetV3, with only 6.69 M of parameters, can give an on-par performance with 93.16% overall DSC, as seen in Table \ref{tab_backbones}. The pre-trained models on ImageNet can also help generalize better if we only have a small amount of data. Moreover, many self-supervised learning algorithms for 2D can also be explored to further improve \texttt{SimLVSeg}{} performance.
2023Proposed M-mode methods (E2E & CL, M=10) proposedTime, Test21.1 msec/sampleEjection Fraction Regression · split: test · variant=E2E & CL, M=10 · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=64M(otion)-mode Based Prediction of Ejection Fraction using Echocardiograms
Source quote
L286: E2E \ │ CL │ 64 │ 11.7 │ 1.568 │ 1.330 │ 24.5 │ 21.1 │ 1.013 │ 0.120
2023Proposed M-mode methods (E2E & CL, M=10) proposedMemory, Test0.120 GB/BEjection Fraction Regression · split: test · variant=E2E & CL, M=10 · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=64M(otion)-mode Based Prediction of Ejection Fraction using Echocardiograms
Source quote
L286: E2E \ │ CL │ 64 │ 11.7 │ 1.568 │ 1.330 │ 24.5 │ 21.1 │ 1.013 │ 0.120
2023ADM-EDM with Discriminator Guidance (DG) proposedFID2.60Image Generation · resolution=64×64 · NFE=59 · sampler=EDM · samples=50000 per epoch · DG-vector-scaling=2Exploring the Hyperparameter Space of Image Diffusion Models for Echocardiogram Generation
Source quote
L49: Once our discriminator is trained, we plug it in the reverse diffusion process as described in~\cite{kim2023refining}, and samples 50,000 for every epoch, in order to find the best performing one. We find that, for the best epoch with the nest set of hyperparameters, the FID improves from 3.75 to 2.60, showing the significance of DG. We use 30 (59 NFE) sampling steps, a weight of 5 for the first order EDM prediction, no guidance for the correction (weight 0) and a scaling of 2 for the Discriminator Guidance vectors.
2023SimLVSeg-SI without SSL pre-training ablationoverall DSC93.19%Video Segmentation · variant=without SSL pre-trainingUniLVSeg: Unified Left Ventricular Segmentation with Sparsely Annotated Echocardiogram Videos through Self-Supervised Temporal Masking and Weakly Supervised Training
Source quote
L189: We observed that randomly masking a significant portion (60%) of an echocardiogram clip during SSL pre-training results in the best performance. The masking SSL improves the overall DSC of the SI approach from 93.19% to 93.31%, as reported in Figure \ref{fig_ssl}. Further, as shown in Fig. \ref{fig:discussion}, we observe that self-supervision with temporal masking enables the network to maintain better temporal consistency across predictions in a given echocardiogram clip. Fig. \ref{fig:discussion_segmentation} demonstrates that a video segmentation model pre-trained with self-supervised temporal masking is more resilient to noise and missing artifacts. The pre-training stage also alleviates the over-segmentation and temporal inconsistency issues that are commonly encountered in echocardiography caused by unclear (or, even worse, invisible) boundaries. Also, the SSL pre-trained model achieves a smoother LV segmentation area prediction with significantly less rapid fluctuations (see Fig. \ref{fig:discussion_lv_area}), indicating better temporal consistency. We further investigate the phenomenon in the frequency domain by applying the Fast Fourier Transform (FFT) to the predicted signals (LV area) as depicted in Fig. \ref{fig:discussion_freq_comp}. We observe that SSL pre-training results in a lower magnitude of the high-frequency components, which are typically the result of noise and rapid fluctuation. Based on these observations, we hypothesize that the pre-training stage helps the 3D U-Net model to better learn the semantic features that are useful for estimating human heart structures in the A4C view, resulting in a more robust prediction. Additionally, Table \ref{tab_ood} showcases the significant impact of the SSL pre-training stage when testing with samples subject to distribution shifts, indicating that the SSL pre-training enhances the model's generalization capability. These findings indicate that pre-training with self-supervision remarkably benefits the downstream LV segmentation task. Hence, self-supervised learning with vast echocardiogram videos can be a promising solution to provide strong pre-trained models that can generalize well in downstream echocardiography-related clinical tasks.
2023EchoAImean absolute error4.34Image Segmentation · fine-tunedEchocardiogram Foundation Model - Application 1: Estimating Ejection Fraction
Source quote
L34: In this work, we introduce EchoAI, a foundation model for echocardiograms. We train EchoAI on a comprehensive dataset comprising 1.5 million echocardiograms. This training dataset encompasses a diverse range of adult and paediatric echocardiograms, including various types and views sourced from both public and Stanford-private datasets. We further fine-tune EchoAI on the EchoNet Dynamic dataset (\cite{ouyang_echonet-dynamic_nodate}) to estimate the ejection fraction (EF). Remarkably, Without any task-specific modifications, EchoAI demonstrates an impressive capability to estimate the ejection fraction, achieving a mean absolute error of 4.34 (9.40%). This performance is noteworthy, especially considering the inherent challenges in ejection fraction estimation. Notably, the inter-user variability for this task is typically 13.5% \cite{farsalinos_head--head_2015}. Furthermore, the process of calculating the ejection fraction involves the intricate steps of detecting individual heartbeats and manually segmenting the left ventricle at both end diastole and systole for each heartbeat, making it a highly time-consuming task.
2023EchoAImean absolute percentage error9.40%Image Segmentation · fine-tunedEchocardiogram Foundation Model - Application 1: Estimating Ejection Fraction
Source quote
L16: Cardiovascular diseases stand as the primary global cause of mortality. Among the various imaging techniques available for visualising the heart and evaluating its function, echocardiograms emerge as the preferred choice due to their safety and low cost. Quantifying cardiac function based on echocardiograms is very laborious, time-consuming and subject to high interoperator variability. In this work, we introduce EchoAI, an echocardiogram foundation model, that is trained using self-supervised learning (SSL) on 1.5 million echocardiograms. We evaluate our approach by fine-tuning EchoAI to estimate the ejection fraction achieving a mean absolute percentage error of 9.40%. This level of accuracy aligns with the performance of expert sonographers.
2023SupCon baselineMAE5.88%Cardiac Function Estimation · split: test · linear-probe · pretraining-epochs=200 · linear-probe-epochs=100SupReMix: Supervised contrastive learning for medical imaging regression with mixup
Source quote
L228: We compare SupReMix against both classification-based (SimCLR \citep{chen2019self}, SupCon \citep{khosla2020supervised}) and regression-based (AdaCon \citep{dai2021adaptive}, RnC \citep{zha2023rank}) representation learning methods across six medical imaging regression datasets spanning different modalities (MRI, X-ray, ultrasound, and PET). As shown in Figure \ref{fig:mae_comparision}, SupReMix consistently achieves lower MAE than all baseline methods. Taking bone age prediction on RSNA as an example, SupReMix reduces the MAE to 4.08 months compared to the classification-based method SupCon (6.79 months). The performance gains are particularly notable in challenging tasks such as cardiac function estimation, where SupReMix achieves an MAE of 4.02 compared to SupCon's 5.88. Moreover, we observe that SupReMix consistently outperforms vanilla regression (shown in dashed line). Additional performance metrics including Mean Squared Error (MSE), correlation coefficient (\rho), and Geometric Mean (GM) error are provided in Tables \ref{table1}, \ref{table2}, \ref{table3}, \ref{table4}, \ref{table5}, \ref{table6}.
2023Thomas et al. [24] baselineMAE4.23 mmEjection Fraction Estimation · split: test · video-setting=single-video A4C/AP4GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular Diagnosis
Source quote
L122: 4.23
2023EchoNet baselineTime, Test123.7 msec/sampleEjection Fraction Regression · split: test · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=20M(otion)-mode Based Prediction of Ejection Fraction using Echocardiograms
Source quote
L285: EchoNet │ 20 │ 31.5 │ 2.898 │ 2.474 │ 144.9 │ 123.7 │ 5.294 │ 1.187
2023EchoNet baselineMemory, Test1.187 GB/BEjection Fraction Regression · split: test · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=20M(otion)-mode Based Prediction of Ejection Fraction using Echocardiograms
Source quote
L285: EchoNet │ 20 │ 31.5 │ 2.898 │ 2.474 │ 144.9 │ 123.7 │ 5.294 │ 1.187
2023ADM-EDM (Ablated Diffusion Model with EDM sampler) baselineFID3.75Image Generation · resolution=64×64 · NFE=59 · sampler=EDM · samples=50000Exploring the Hyperparameter Space of Image Diffusion Models for Echocardiogram Generation
Source quote
L40: In Table~\ref{tab:exp_setup}, the best performing model is the ADM-EDM~\cite{dhariwal2021diffusion}, with an FID of 3.75 when generating over 59 Neural Function Executions (NFE), equivalent to 30 EDM steps. We can see on Figure~\ref{fig:fid_step} that the FID decreases abruptly once we reach the 35 NFE mark, and plateaus afterward.
2022EchoCoTr proposedMAE3.95Ejection Fraction Estimation · modality=echocardiography videoEchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal Echocardiography
Source quote
L4: Learning spatiotemporal features is an important task for efficient video understanding especially in medical images such as echocardiograms. Convolutional neural networks (CNNs) and more recent vision transformers (ViTs) are the most commonly used methods with limitations per each. CNNs are good at capturing local context but fail to learn global information across video frames. On the other hand, vision transformers can incorporate global details and long sequences but are computationally expensive and typically require more data to train. In this paper, we propose a method that addresses the limitations we typically face when training on medical video data such as echocardiographic scans. The algorithm we propose (EchoCoTr) utilizes the strength of vision transformers and CNNs to tackle the problem of estimating the left ventricular ejection fraction (LVEF) on ultrasound videos. We demonstrate how the proposed method outperforms state-of-the-art work to-date on the EchoNet-Dynamic dataset with MAE of 3.95 and R^2 of 0.82. These results show noticeable improvement compared to all published research. In addition, we show extensive ablations and comparisons with several algorithms, including ViT and BERT. The code is available
2022EchoCoTr proposedR^20.82Ejection Fraction Estimation · modality=echocardiography videoEchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal Echocardiography
Source quote
L4: Learning spatiotemporal features is an important task for efficient video understanding especially in medical images such as echocardiograms. Convolutional neural networks (CNNs) and more recent vision transformers (ViTs) are the most commonly used methods with limitations per each. CNNs are good at capturing local context but fail to learn global information across video frames. On the other hand, vision transformers can incorporate global details and long sequences but are computationally expensive and typically require more data to train. In this paper, we propose a method that addresses the limitations we typically face when training on medical video data such as echocardiographic scans. The algorithm we propose (EchoCoTr) utilizes the strength of vision transformers and CNNs to tackle the problem of estimating the left ventricular ejection fraction (LVEF) on ultrasound videos. We demonstrate how the proposed method outperforms state-of-the-art work to-date on the EchoNet-Dynamic dataset with MAE of 3.95 and R^2 of 0.82. These results show noticeable improvement compared to all published research. In addition, we show extensive ablations and comparisons with several algorithms, including ViT and BERT. The code is available
2022SimCLR-pretrained DeepLabV3 proposedDice score0.9252Image Segmentation · backbone=DeepLabV3 · pretraining=SimCLRContrastive Pretraining for Echocardiography Segmentation with Limited Data
Source quote
L101: 3 │ SimCLR │ DeepLabV3 │ 0.9252 (0.0476) │ 0.9242 (0.0452) │ 0.9190 (0.0509) │ 0.9125 (0.0548)
2022SimCLR-pretrained DeepLabV3 proposedDice score0.9125Image Segmentation · fine-tuned · backbone=DeepLabV3 · pretraining=SimCLR · data-fraction=5%Contrastive Pretraining for Echocardiography Segmentation with Limited Data
Source quote
L155: As Table \ref{tab:echo} shows, our proposed self supervised method which uses DeepLabV3 with a SimCLR pretrained backbone outperformed all other methods (including the EchoNet-Dynamic \cite{echonetdynamic} baseline - 0.9211 Dice), regardless of the amount of data. In fact, with only 5% of the data, our method produces results (0.9125 Dice) that are close to fully supervised training with all of the available data (0.9229 Dice). Furthermore, with the UNet architecture, SimCLR was found to be beneficial although the improvement was minor. We also found ImageNet pretraining to perform better than random initialization. However, BYOL did not have any significant benefit over ImageNet pretraining or even random initialization. Finally, DeepLabV3 performed better than UNet in the segmentation task.
2022DTGN (D'ARTAGNAN) proposedSSIM0.79Counterfactual Video Generation · selection=best of 100 sampled U_Y valuesD'ARTAGNAN: Counterfactual Video Generation
Source quote
L105: SSIM │ 0.82 │ 0.79
2022DTGN (D'ARTAGNAN) proposedR20.51Counterfactual Video Generation · selection=best of 100 sampled U_Y valuesD'ARTAGNAN: Counterfactual Video Generation
Source quote
L102: R2 │ 0.87 │ 0.51
2022DTGN (D'ARTAGNAN) proposedMAE15.7%Counterfactual Ef Prediction · selection=best of 100 sampled U_Y valuesD'ARTAGNAN: Counterfactual Video Generation
Source quote
L103: MAE │ 2.79 │ 15.7
2022EchoGNN proposedMAE4.45Ejection Fraction EstimationEchoGNN: Explainable Ejection Fraction Estimation with Graph Neural Networks
Source quote
L142: 0.76 4.45
2022EchoGNN proposed non-standard sliceED aFD (average frame distance)3.68End Diastolic Frame Localization · subset=1,173 periodic-data cases · supervision=no ground-truth ES/ED locationsEchoGNN: Explainable Ejection Fraction Estimation with Graph Neural Networks
Source quote
L145: 3.68
2022DeepLabV3 (Ouyang et al.) baselineDice score0.9211Image Segmentation · backbone=DeepLabV3Contrastive Pretraining for Echocardiography Segmentation with Limited Data
Source quote
L31: Furthermore, \cite{ouyang2020video} attempted the same task, training on their large publicly available EchoNet-Dynamic dataset \cite{ouyang2019echonet}, containing 20,060 annotated images from 10,030 patients. A DeepLabV3 \cite{chen2017deeplab} network was chosen for this task and obtained a Dice score of 0.9211.
2022Fully supervised training baselineDice score0.9229Image Segmentation · training=fully-supervised · data-fraction=100%Contrastive Pretraining for Echocardiography Segmentation with Limited Data
Source quote
L155: As Table \ref{tab:echo} shows, our proposed self supervised method which uses DeepLabV3 with a SimCLR pretrained backbone outperformed all other methods (including the EchoNet-Dynamic \cite{echonetdynamic} baseline - 0.9211 Dice), regardless of the amount of data. In fact, with only 5% of the data, our method produces results (0.9125 Dice) that are close to fully supervised training with all of the available data (0.9229 Dice). Furthermore, with the UNet architecture, SimCLR was found to be beneficial although the improvement was minor. We also found ImageNet pretraining to perform better than random initialization. However, BYOL did not have any significant benefit over ImageNet pretraining or even random initialization. Finally, DeepLabV3 performed better than UNet in the segmentation task.
2022Bayesian [12] baselineMAE4.46Ejection Fraction EstimationEchoGNN: Explainable Ejection Fraction Estimation with Graph Neural Networks
Source quote
L136: 0.75 4.46
2022Transformer (R) [21] baseline non-standard sliceED aFD (average frame distance)7.88End Diastolic Frame Localization · subset=periodic-data cases · supervision=ground-truth ES/ED locationsEchoGNN: Explainable Ejection Fraction Estimation with Graph Neural Networks
Source quote
L128: 7.88
2021Echo-SyncNet proposed non-standard sliceMean Absolute Error (ED key-frame detection)79.1 msKey Frame Detection · split: val · 1-shot · training-views=AP4, AP2, PLAXEcho-SyncNet: Self-supervised Cardiac View Synchronization in Echocardiography
Source quote
L258: ms │ 79.1 │ 61.1 │ 128.5 │ 90.1
2021Echo-SyncNet proposed non-standard sliceMean Absolute Error (ES key-frame detection)61.1 msKey Frame Detection · split: val · 1-shot · training-views=AP4, AP2, PLAXEcho-SyncNet: Self-supervised Cardiac View Synchronization in Echocardiography
Source quote
L258: ms │ 79.1 │ 61.1 │ 128.5 │ 90.1
2021UVT (M./Reg., ours) proposedAverage frame distance (aFD)3.35 framesEnd Systolic Frame Detection · split: test · video-sampling=mirror/regularUltrasound Video Transformers for Cardiac Ejection Fraction Estimation
Source quote
L102: M./Reg. (ours) │ 0.08 (1.53) │ 0.15 (1.89) │ 3.35 (6.79) │ 7.17 (12.92) │ 6
2021UVT (M./Reg., ours) proposedAverage frame distance (aFD)7.17 framesEnd Diastolic Frame Detection · split: test · video-sampling=mirror/regularUltrasound Video Transformers for Cardiac Ejection Fraction Estimation
Source quote
L102: M./Reg. (ours) │ 0.08 (1.53) │ 0.15 (1.89) │ 3.35 (6.79) │ 7.17 (12.92) │ 6
2021UVT (M., mirror video sampling) proposed non-standard sliceMAE5.95Ejection Fraction Estimation · video-sampling=mirrorUltrasound Video Transformers for Cardiac Ejection Fraction Estimation
Source quote
L114: M. (ours) │ 5.32 (4.90) │ 7.23 │ 0.64 │ 5.95 (5.90) │ 8.38 │ 0.52