EchoNet-Dynamic · Image Segmentation
32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API
Tasks on EchoNet-DynamicAll tasks (32)Image Segmentation (11)Ejection Fraction Estimation (7)Ejection Fraction Regression (2)Image Generation (2)Video Generation (2)Binary Classification (1)Cardiac Function Estimation (1)Classification (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Image Segmentation: proposed/measured results on test (including papers where test split is standard/implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MCSDR (vision-only) SOTA frontier | 3.76 | 2026-02-01 | Test set; evaluated in vision-only mode to avoid label leakage from derived text attr… | Generative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography VideoSource quoteDespite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89). |
| 2 | CoReEcho SOTA frontier | 3.9 | 2024-01-01 | EF regression; predictions from three sampled clips averaged for each video. | CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography AnalysisSource quoteComparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.} |
Other primary task on EchoNet-Dynamic: Image Segmentation · mDice ↑ (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SAMUS SOTA frontier | 91.79 | 2024-01-01 | EchoNet-Dynamic videos have labels only for end-systolic and end-diastolic phases; ev… | MemSAM: Taming Segment Anything Model for Echocardiography Video SegmentationSource quote91.79 |
| 2 | EchoONE | 88.36 | 2025-01-01 | training=not used · evaluation=external · External evaluation; EchoNet-Dynamic was not used for training. | EchoONE: Segmenting Multiple Echocardiography Planes in One ModelSource quoteEchoONE │ 73.94 │ 59.31 │ 88.36 │ 79.65 |
TaskImage Segmentation (24)Ejection Fraction Estimation (13)Video Generation (6)Ejection Fraction Regression (5)Left Ventricular Ejection Fraction Prediction (5)Binary Classification (4)Video Segmentation (4)
Showing 13 of 13 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Single-parameter latent orbit features with supervised MLP prediction head proposed | EF MAE | 6.02% | Image Segmentation | Self-Supervised Cardiac Phase Detection via Single-Parameter Latent OrbitsSource quoteL143: We compare our approach with LMP~\cite{yangLatentMotionProfiling2026} by training an equivalent MLP head using the concatenation of its structure and motion features. Our method yields improved EF prediction performance (6.02% MAE vs.\ 6.27% MAE) with one-tenth as many pre-training epochs, indicating that the proposed cyclic prior provides a strong inductive bias for capturing motion cues relevant to cardiac function assessment. Fully supervised methods (e.g., \cite{maani2024coreecho}) act as an upper bound. |
| 2025 | EchoVLM proposed | Dice similarity coefficient (DSC) | 93.1% | Image Segmentation · view=A4C | EchoVLM: Measurement-Grounded Multimodal Learning for EchocardiographySource quoteL134: EchoVLM outperforms tasks-specialists and achieves similar performance as vision FM. EchoVLM attains the best DSC on EchoNet-Dynamic (93.1%) and EchoNet-Pediatric-A4C (92.4%), and ties EchoApex on EchoNet-Pediatric-PSAX (93.0%) (Table \ref{tab: seg}). On the CAMUS dataset, EchoVLM matches EchoApex for left ventricular segmentation (93.8%) and achieves competitive performance for left atrial segmentation (90.2%). Visualization of segmentation results on CAMUS using EchoVLM is shown in Figure \ref{fig:camus1}. These results indicate that our pretraining maintains transferable local features for segmentation across datasets. |
| 2025 | HSS-Net (full method) proposed | Dice | 92.67 | Image Segmentation | Hierarchical Spatio-Temporal Segmentation Network for Ejection Fraction Estimation in Echocardiography VideosSource quoteL159: HSS-Net~(Ours) │ \textBF{90.47} │ \textBF{2.43±5.02} │ \textBF{93.89} │ \textBF{11.29} │ \textBF{84.50} │ \textBF{0.95±6.75} │ \textBF{92.67} │ \textBF{2.66} |
| 2024 | Adaptive (w/ aug & LD) proposed non-standard slice | Dice score (LV) | 0.910 | Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=used | Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial LabellingSource quoteL117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689 |
| 2024 | Adaptive (w/ aug & LD) proposed non-standard slice | Dice score (LVM) | 0.518 | Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=used | Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial LabellingSource quoteL117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689 |
| 2024 | Adaptive (w/ aug & LD) proposed non-standard slice | Dice score (LA) | 0.689 | Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=used | Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial LabellingSource quoteL117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689 |
| 2024 | CoReEcho proposed | MAE | 3.90 | Image Segmentation | CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography AnalysisSource quoteL189: Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.} |
| 2024 | CoReEcho proposed | R2 | 82.44 | Image Segmentation | CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography AnalysisSource quoteL4: Deep learning (DL) models have been advancing automatic medical image analysis on various modalities, including echocardiography, by offering a comprehensive end-to-end training pipeline. This approach enables DL models to regress ejection fraction (EF) directly from 2D+time echocardiograms, resulting in superior performance. However, the end-to-end training pipeline makes the learned representations less explainable. The representations may also fail to capture the continuous relation among echocardiogram clips, indicating the existence of spurious correlations, which can negatively affect the generalization. To mitigate this issue, we propose \texttt{CoReEcho}{}, a novel training framework emphasizing continuous representations tailored for direct EF regression. Our extensive experiments demonstrate that \texttt{CoReEcho}{}: 1) outperforms the current state-of-the-art (SOTA) on the largest echocardiography dataset (EchoNet-Dynamic) with MAE of 3.90 \ │ R2 of 82.44, and 2) provides robust and generalizable features that transfer more effectively in related downstream tasks. The code is publicly available at \url{https://github.com/BioMedIA-MBZUAI/CoReEcho}. |
| 2024 | CoReEcho proposed | RMSE | 5.13 | Image Segmentation | CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography AnalysisSource quoteL189: Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.} |
| 2024 | EchoONE proposed | mDice | 88.36 | Image Segmentation · training=not used · evaluation=external | EchoONE: Segmenting Multiple Echocardiography Planes in One ModelSource quoteL256: EchoONE │ 73.94 │ 59.31 │ 88.36 │ 79.65 |
| 2023 | filter-pruned DeepLabV3 proposed | compression rate | 1148x × | Image Segmentation · compressed · params=34.5K · pruning-rate=98.4% | Sculpting Efficiency: Pruning Medical Imaging Models for On-Device InferenceSource quoteL35: In Figure \ref{fig:results}, globally weight-pruned models exhibit impeccable resiliency, maintaining quality within 1% of the baseline even at a sparsity of 98.4% (633K params.). On the contrary, a local strategy (not depicted) deteriorates model quality at high targets \cite{blalock2020state}; some layers are more sensitive than others. Our filter pruning results corroborate the overarching observation that DeepLabV3 is substantially overparameterized for this task. Specifically, the most extreme case, with 98.4% filters pruned, yields DICE scores within 4% of the baseline while being 1148x smaller (34.5K params.). Moreover, the optimal filter pruned model (0.875) deviates from the baseline by only 0.7% while offering 7.5x higher throughput at 233 FPS, making it more than viable for real-time use. This model is just as fast on a CPU as the GPU baseline, a profound improvement that results solely from pruning. |
| 2022 | SimCLR-pretrained DeepLabV3 proposed | Dice score | 0.9252 | Image Segmentation · backbone=DeepLabV3 · pretraining=SimCLR | Contrastive Pretraining for Echocardiography Segmentation with Limited DataSource quoteL101: 3 │ SimCLR │ DeepLabV3 │ 0.9252 (0.0476) │ 0.9242 (0.0452) │ 0.9190 (0.0509) │ 0.9125 (0.0548) |
| 2022 | SimCLR-pretrained DeepLabV3 proposed | Dice score | 0.9125 | Image Segmentation · fine-tuned · backbone=DeepLabV3 · pretraining=SimCLR · data-fraction=5% | Contrastive Pretraining for Echocardiography Segmentation with Limited DataSource quoteL155: As Table \ref{tab:echo} shows, our proposed self supervised method which uses DeepLabV3 with a SimCLR pretrained backbone outperformed all other methods (including the EchoNet-Dynamic \cite{echonetdynamic} baseline - 0.9211 Dice), regardless of the amount of data. In fact, with only 5% of the data, our method produces results (0.9125 Dice) that are close to fully supervised training with all of the available data (0.9229 Dice). Furthermore, with the UNet architecture, SimCLR was found to be beneficial although the improvement was minor. We also found ImageNet pretraining to perform better than random initialization. However, BYOL did not have any significant benefit over ImageNet pretraining or even random initialization. Finally, DeepLabV3 performed better than UNet in the segmentation task. |