EchoNet-Dynamic · Image Segmentation

32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Image Segmentation: proposed/measured results on test (including papers where test split is standard/implicit).

3.73.83.93.9202420252026CoReEcho: 3.9 (2024)MCSDR (vision-only): 3.76 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 5 of 5 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Single-parameter latent orbit features with supervised MLP prediction head proposedEF MAE6.02%Image SegmentationSelf-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits
Source quote
L143: We compare our approach with LMP~\cite{yangLatentMotionProfiling2026} by training an equivalent MLP head using the concatenation of its structure and motion features. Our method yields improved EF prediction performance (6.02% MAE vs.\ 6.27% MAE) with one-tenth as many pre-training epochs, indicating that the proposed cyclic prior provides a strong inductive bias for capturing motion cues relevant to cardiac function assessment. Fully supervised methods (e.g., \cite{maani2024coreecho}) act as an upper bound.
2026MCSDR (vision-only)MAE3.76Image Segmentation · split: testGenerative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video
Source quote
L191: Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89).
2026LMP features with an equivalent supervised MLP prediction headEF MAE6.27%Image SegmentationSelf-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits
Source quote
L143: We compare our approach with LMP~\cite{yangLatentMotionProfiling2026} by training an equivalent MLP head using the concatenation of its structure and motion features. Our method yields improved EF prediction performance (6.02% MAE vs.\ 6.27% MAE) with one-tenth as many pre-training epochs, indicating that the proposed cyclic prior provides a strong inductive bias for capturing motion cues relevant to cardiac function assessment. Fully supervised methods (e.g., \cite{maani2024coreecho}) act as an upper bound.
2026PanEcho baselineMAE5.35Image Segmentation · split: testGenerative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video
Source quote
L191: Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89).
2024CoReEcho proposedMAE3.90Image SegmentationCoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis
Source quote
L189: Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.}