EchoNet-Dynamic · Image Segmentation
32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API
Tasks on EchoNet-DynamicAll tasks (32)Image Segmentation (11)Ejection Fraction Estimation (7)Ejection Fraction Regression (2)Image Generation (2)Video Generation (2)Binary Classification (1)Cardiac Function Estimation (1)Classification (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Image Segmentation: proposed/measured results on test (including papers where test split is standard/implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MCSDR (vision-only) SOTA frontier | 3.76 | 2026-02-01 | Test set; evaluated in vision-only mode to avoid label leakage from derived text attr… | Generative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography VideoSource quoteDespite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89). |
| 2 | CoReEcho SOTA frontier | 3.9 | 2024-01-01 | EF regression; predictions from three sampled clips averaged for each video. | CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography AnalysisSource quoteComparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.} |
Other primary task on EchoNet-Dynamic: Image Segmentation · mDice ↑ (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SAMUS SOTA frontier | 91.79 | 2024-01-01 | EchoNet-Dynamic videos have labels only for end-systolic and end-diastolic phases; ev… | MemSAM: Taming Segment Anything Model for Echocardiography Video SegmentationSource quote91.79 |
| 2 | EchoONE | 88.36 | 2025-01-01 | training=not used · evaluation=external · External evaluation; EchoNet-Dynamic was not used for training. | EchoONE: Segmenting Multiple Echocardiography Planes in One ModelSource quoteEchoONE │ 73.94 │ 59.31 │ 88.36 │ 79.65 |
TaskImage Segmentation (24)Ejection Fraction Estimation (13)Video Generation (6)Ejection Fraction Regression (5)Left Ventricular Ejection Fraction Prediction (5)Binary Classification (4)Video Segmentation (4)
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2022 | SimCLR-pretrained DeepLabV3 proposed | Dice score | 0.9252 | Image Segmentation · backbone=DeepLabV3 · pretraining=SimCLR | Contrastive Pretraining for Echocardiography Segmentation with Limited DataSource quoteL101: 3 │ SimCLR │ DeepLabV3 │ 0.9252 (0.0476) │ 0.9242 (0.0452) │ 0.9190 (0.0509) │ 0.9125 (0.0548) |
| 2022 | SimCLR-pretrained DeepLabV3 proposed | Dice score | 0.9125 | Image Segmentation · fine-tuned · backbone=DeepLabV3 · pretraining=SimCLR · data-fraction=5% | Contrastive Pretraining for Echocardiography Segmentation with Limited DataSource quoteL155: As Table \ref{tab:echo} shows, our proposed self supervised method which uses DeepLabV3 with a SimCLR pretrained backbone outperformed all other methods (including the EchoNet-Dynamic \cite{echonetdynamic} baseline - 0.9211 Dice), regardless of the amount of data. In fact, with only 5% of the data, our method produces results (0.9125 Dice) that are close to fully supervised training with all of the available data (0.9229 Dice). Furthermore, with the UNet architecture, SimCLR was found to be beneficial although the improvement was minor. We also found ImageNet pretraining to perform better than random initialization. However, BYOL did not have any significant benefit over ImageNet pretraining or even random initialization. Finally, DeepLabV3 performed better than UNet in the segmentation task. |
| 2022 | DeepLabV3 (Ouyang et al.) baseline | Dice score | 0.9211 | Image Segmentation · backbone=DeepLabV3 | Contrastive Pretraining for Echocardiography Segmentation with Limited DataSource quoteL31: Furthermore, \cite{ouyang2020video} attempted the same task, training on their large publicly available EchoNet-Dynamic dataset \cite{ouyang2019echonet}, containing 20,060 annotated images from 10,030 patients. A DeepLabV3 \cite{chen2017deeplab} network was chosen for this task and obtained a Dice score of 0.9211. |
| 2022 | Fully supervised training baseline | Dice score | 0.9229 | Image Segmentation · training=fully-supervised · data-fraction=100% | Contrastive Pretraining for Echocardiography Segmentation with Limited DataSource quoteL155: As Table \ref{tab:echo} shows, our proposed self supervised method which uses DeepLabV3 with a SimCLR pretrained backbone outperformed all other methods (including the EchoNet-Dynamic \cite{echonetdynamic} baseline - 0.9211 Dice), regardless of the amount of data. In fact, with only 5% of the data, our method produces results (0.9125 Dice) that are close to fully supervised training with all of the available data (0.9229 Dice). Furthermore, with the UNet architecture, SimCLR was found to be beneficial although the improvement was minor. We also found ImageNet pretraining to perform better than random initialization. However, BYOL did not have any significant benefit over ImageNet pretraining or even random initialization. Finally, DeepLabV3 performed better than UNet in the segmentation task. |