TL;DR
Reading a 3D computed tomography (CT) scan is like hunting for needles across thousands of digital haystacks—and until now, medical AI could mostly only look for one specific type of needle in one specific body part at a time. FORA changes the game: it is a single, general-purpose AI model that recognizes over 1,000 distinct abnormalities across the entire human body, points to exactly where they are in 3D space, and writes a complete radiology report. Remarkably, it learns to pinpoint these lesions without a single human-drawn bounding box, relying solely on the routine text reports doctors already write every day.
What Problem Does This Paper Address?
Every year, patients in the US alone undergo roughly 93 million CT scans. A single scan contains thousands of cross-sectional slices spanning multiple organs, and radiologists are increasingly overwhelmed.
Existing AI solutions have been split down two frustratingly narrow paths:
- Specialist detectors (and early foundation models) that spot specific diseases in specific organs (e.g., lung nodules in chest CTs), requiring hospitals to juggle dozens of piecemeal models.
- Report generators that write fluent, plausible-sounding summaries from 3D scans, but frequently miss critical findings or hallucinate claims without showing where in the scan they saw the evidence.
To build an AI that grounds its claims in visual locations, researchers usually need massive datasets where radiologists have painstakingly outlined lesions slice by slice. That simply doesn't scale to the thousand-plus weird and wonderful things that can go wrong in human anatomy. The authors ask: Can we train one unified model to recognize, locate, and report virtually everything across any CT scan, using only routine clinical text reports as supervision?
Methods
FORA bridges 3D pixels and clinical prose using an interpretable concept bottleneck paired with multiple-instance learning (MIL)—a technique where a model is told what is inside a giant bag of data (the whole scan), and has to figure out which specific pieces (3D image patches) are responsible.
Here is how the pipeline comes together:
- Multi-Window 3D Vision Encoder: Radiologists adjust brightness/contrast settings ("windows") to view bone, lung, or soft tissue. FORA feeds all available views into a 303M-parameter 3D Vision Transformer (ViT-L), pre-trained from scratch via self-supervised distillation (DINO/iBOT).
- LLM-Curated Concept Hierarchy: Rather than relying on noisy raw text, the authors used an LLM pipeline (Gemma-4-31B-it) to extract, quote-verify, and organize 1,028 radiological concepts (based on Radiopaedia) from clinical reports into a 5-level hierarchy.
- Organ-Routed Attention (The Novel Localization Trick): To predict whether any of the 1,028 concepts are present, a gated attention head scans the 3D image tokens. Crucially, the authors introduce anatomical routing: using automated organ segmentations (CADS), each concept's attention is softly penalized if it looks outside its relevant organ system, while still leaving the whole scan accessible for anomalies like an ectopic (misplaced) kidney. The resulting attention maps naturally highlight lesions in 3D space!
- Concept-Guided Report Generation: Finally, a fine-tuned Gemma-4-31B writer drafts the report. Instead of guessing from raw visual features alone, it receives an explicit "report plan" listing detected concepts, their calibrated probabilities, 3D locations, and zoomed-in image crops—alongside global visual tokens to catch nuances outside the 1,028-word vocabulary. Direct Preference Optimization (DPO) trains the writer not to lazily omit findings from its plan.
(Note: The authors first validated this entire recipe in 2D on chest X-rays before scaling up to 3D CT.)
Datasets
- Internal CT Cohort (New): 341,581 routine CT exams (2.61 million windowed views) from 238,469 patients across 28 scan protocols (head, chest, abdomen, spine, angiography, etc.) from a hospital network, with reports translated from Turkish to English. Split by patient into 304,962 training and 36,619 held-out test exams.
- Public CT Classification Benchmarks: CT-RATE, Merlin, RAD-ChestCT, KiTS23, and RibFrac.
- Public CT Localization Benchmarks: FUMPE (pulmonary embolism), KiTS23 (kidney cysts/masses), RibFrac (rib fractures), and ReXGroundingCT (chest findings).
- Chest Radiograph Cohort & Benchmarks: 286,560 internal X-ray studies (publicly released on HuggingFace), plus RSNA Pneumonia, Open-I, ChestX-Det10, ChestX-ray14, and PadChest-GR.
Key Insights and Ideas
- Free spatial supervision at scale: Routine clinical reports don't have pixel coordinates, yet combining exam-level concept labels with organ-routed MIL forces the network to point directly at tiny abnormalities—like pulmonary emboli or rib fractures—hundreds of times better than random chance within that anatomy.
- Concepts beat pure contrastive matching: Contrastive models (like CLIP) guess diseases by comparing image embeddings to text prompts, making them sensitive to phrasing. Predicting an explicit bottleneck of 1,028 concepts gives FORA calibrated probabilities and dramatically higher precision on rare findings.
- SFT writers are lazy; DPO wakes them up: Even when handed a checklist of detected abnormalities, a standard supervised LLM omitted 72.1% of reference findings. Adding DPO—penalizing synthetic omissions and hallucinations—slashed omissions to 40.8% and more than doubled finding recall.
- Hidden quantitative biomarkers: Linear probes on FORA’s frozen visual encoder accurately recovered continuous physical measurements never explicitly taught in its vocabulary, such as liver attenuation ($r = 0.990$), muscle density, and aortic calcification, while concept profiles acted like stable "patient fingerprints" across repeat visits.
Key Results
FORA decisively outperformed 18 released CT foundation and vision-language models across recognition, localization, and reporting:
- Concept Recognition: On the 36,619 held-out CTs, FORA hit a macro AUROC of 0.918 (vs. 0.705 for the best alternative, CoLiPri) and won on 95.7% of 2,132 finding–exam-type pairs. Zero-shot on external data, it beat Merlin on Merlin's own home-institution test set (0.907 vs. 0.826 AUROC).
- Weakly Supervised Localization: Without seeing a single lesion mask during training, FORA’s top evidence focus landed directly inside ground-truth annotations 69.7% of the time for pulmonary emboli ($348\times$ chance), 72.8% for renal masses, 66.1% for renal cysts, and 58.3% for rib fractures ($188\times$ chance), beating specialized localization models RADAR and GLINT-CT.
- Report Generation: Against 7 CT report generators, FORA achieved over $3\times$ higher macro finding recall (0.215 vs. 0.066 for NV-Reason-CT) and more than doubled precision (0.285 vs. 0.132). An LLM judge preferred FORA's reports 73.8% of the time in head-to-head matchups against NV-Reason-CT.
Limitations and Future Work
- Single-network & translation bias: Training data came from one hospital network with reports machine-translated from Turkish to English. Institutional reporting habits—like leaving minor, normal-for-age findings unmentioned—are baked into the supervision.
- Correlational, not causal, maps: While FORA's evidence maps mathematically sum up to the model's prediction, localization was only quantitatively verified on datasets where masks exist; proving true causal dependence would require interventional occlusion tests.
- Automated judging: Report quality was graded at scale via LLM extractors and judges, which cannot replace real radiologists in clinical reader studies.
- What's next: Conducting prospective clinical trials to measure impact on radiologist speed and diagnostic error, incorporating prior scans to track longitudinal disease progression ("new vs. stable"), and bringing this exact report-supervised recipe to MRI.
Summary updated