Glance Before You Tell: Anomaly-Guided 3D Radiology Report Generation with Heat-Conduction Slice Encoders

Lingyu Zhou, Dingwen Pi, Zhang Yi, Jun Wu, Xiuyuan XuNeurIPS 2026

TL;DR

Teaching AI to write radiology reports from massive 3D CT scans usually triggers hallucinations—like describing tumors that simply aren't there. HEATRAD tackles this by mimicking how human radiologists actually work: "glancing before telling." By filtering out healthy background anatomy in the frequency domain, flagging suspicious slices, and organizing them by organ before generating text, it boosts clinical accuracy without needing expensive pixel-level masks.

What Problem Does This Paper Address?

Multimodal Large Language Models (MLLMs) are surprisingly fluent at drafting diagnostic reports from 3D CT scans, yet they suffer from a dangerous habit: hallucinating medical findings. Because 3D volumes are packed with repetitive, healthy tissue, tiny lesions easily get drowned out, tempting the language model to guess based on statistical priors rather than actual visual evidence.

Current fixes try to "ground" generation in two main ways, both of which have catches:

  1. External Segmentation Models: Using a pre-trained vision tool to chop the scan into organ masks first. If the segmenter misses a spot or mislabels a boundary, that error propagates straight into the report as an apparently "grounded" fact.
  2. Fixed Phrase Queues: Matching image regions against a preset dictionary of common medical terms. Because real-world pathology is long-tailed and complex, fixed lists tend to over-trigger common textbook diagnoses while completely missing rare or subtle ones.
Figure 1: HEATRAD avoids external segmenters and fixed queues by discovering suspicious slices, attributing organ-level evidence, and forming a sparse prefix for report generation.

The authors ask: Can we ground 3D report generation by hunting for anomalies first—just like a doctor scrolling through a scan—using only paired scans and text reports for training?

Methods

HEATRAD separates where to look from what to say via an end-to-end differentiable pipeline connected to a LoRA-tuned Llama3-8B decoder:

  • Signed Heat-Conduction Slice Encoder (Novel): Standard 3D self-attention scales quadratically ($\mathcal{O}(N^2)$) and blurs sparse lesions into the surrounding healthy tissue. The authors adapt the recent Heat Conduction Operator ($\mathcal{O}(N^{1.5})$), which processes images in the frequency domain via Discrete Cosine Transforms (DCT). Crucially, they make it signed within each 2D slice: positive diffusivity dampens smooth, low-frequency background anatomy, while negative diffusivity amplifies sharp, high-frequency lesion residues. A standard, non-negative 1D operator is applied across slices at the end to share 3D context without smearing slice-specific locations.
Heat-Conduction Slice Encoder
  • Stage I – Suspicious-Slice Discovery: Each slice is pooled and compared against learnable "normal" and "abnormal" prototype anchors conditioned on the whole scan, yielding a soft, continuous anomaly probability per slice.
  • Stage II – Organ-Attributed Confirmation: Instead of external pixel masks, HEATRAD uses 32 frozen biomedical text embeddings (e.g., "the lung region") as cross-attention queries over each slice, grouping suspicious visual features into stable anatomical buckets.
  • Stage III – Adaptive Sparse Selection: Organ-slice relevance scores are fed into a sparsemax sampler paired with a learnable "abstain" anchor. Unlike rigid Top-$k$ filtering, sparsemax assigns exact zeros to irrelevant slices—absorbing all weight into the abstain slot if an organ looks healthy—and packs the surviving evidence into an organ-ordered visual prefix for the LLM.
Stage III: Anomaly-Guided Report Generation

Datasets

No new datasets are introduced. All models are trained and evaluated on three public, de-identified 3D chest CT benchmarks (resampled to $64 \times 256 \times 256$):

  • RadGenome-ChestCT: 25,692 volume–report pairs (extending CT-RATE) featuring region-level anatomical and abnormality annotations used exclusively to evaluate spatial grounding.
  • BIMCV-R: 8,069 chest CT scans spanning 96 disease entities across oncologic, infectious, cardiopulmonary, and respiratory conditions.
  • CTRG-Chest: 1,804 paired chest CT volumes and reports (evaluating on the findings section).

Key Insights and Ideas

  • Reverse "heat diffusion" acts as a natural lesion highlighter: Standard heat conduction smooths signals out. Removing the positivity constraint turns the spectral gate into a simultaneous low-pass suppressor and high-pass amplifier—quieting predictable organ shapes while making focal anomalies pop.
  • Slice addressability beats isotropic 3D mixing: Ablations show that applying 3D heat conduction across the whole volume at once blurs slice boundaries and drops grounding accuracy (Hit@1 falls from 0.793 to 0.756). Keeping the heavy lifting 2D and adding light axial diffusion late preserves exact "slice addresses."
  • Knowing when to say nothing: Medical scans vary wildly—one patient has a single tiny nodule, another has diffuse bilateral fluid. Pairing sparsemax with an abstain token lets the prefix dynamically shrink or expand, outperforming tuned hard Top-$K$ selection without needing explicit spatial supervision.

Key Results

  • Clinical Efficacy: HEATRAD outperforms 2D-adapted and native 3D baselines across all three benchmarks. Entity-level Clinical F1 rises over the strongest baseline (DEAR) from 0.677 to 0.702 on RadGenome-ChestCT, 0.256 to 0.281 on BIMCV-R, and 0.306 to 0.328 on CTRG-Chest, with the biggest jumps occurring in rare, long-tail abnormalities.
  • Unsupervised Grounding: Even though it never sees bounding boxes or masks during training, HEATRAD's slice anomaly scores achieve an AUROC of 0.871 against ground-truth lesion masks (vs. 0.71 for DEAR), reaching 96% of the Clinical F1 of an Oracle given human-annotated slice locations.
  • Parameter Efficiency: The signed heat-conduction encoder outperforms a signed self-attention equivalent while using 0.61$\times$ the parameters (21.3M vs. 34.7M), and beats an 86.2M-parameter 3D ViT.

Limitations and Future Work

  • Anatomical Scope & Shift: Evaluation is restricted to chest CTs. Furthermore, relying on a frozen text encoder and fixed RadLex organ prompts could propagate errors under domain shift, or falter on patients with post-surgical or congenital anatomical variations.
  • Uncalibrated Scores & Compute: The slice suspiciousness score acts as an internal routing gate rather than a calibrated clinical probability, and the 8B-parameter LLM still dominates inference latency.
  • Future Directions: The authors plan to expand validation to other 3D imaging modalities and body regions, noting that no human radiologist reader study has been conducted yet and emphasizing the system is strictly an assistive research prototype.

Summary updated

Abstract

Generating accurate radiology reports from 3D medical volumes remains prone to hallucination. Existing grounding strategies often depend on external visual foundation models or on fixed medical phrase queues. The former passes segmenter-derived evidence to generation, where segmentation errors are hard to suppress. The latter has limited coverage of long-tail and compositional abnormalities. We therefore propose HeatRAD, a glance-before-tell framework that first routes suspicious slice evidence into an organ-ordered visual prefix, then generates reports from this localized evidence without explicit grounding supervision. HeatRAD uses a slice-centric signed heat-conduction encoder that performs efficient spectral mixing while separating smooth anatomy from lesion-like residues. HeatRAD then scores suspicious slices, binds their evidence to coarse organ contexts, and assembles an organ-ordered visual prefix, guiding the decoder toward localized abnormalities instead of redundant volumetric context. Experiments on three 3D radiology benchmarks show consistent gains in clinical fidelity and hallucination-related metrics, supporting anomaly-first evidence selection as an annotation-efficient paradigm for 3D report generation.
BibTeX
@inproceedings{zhou2026glance,
  author = {Lingyu Zhou and Dingwen Pi and Zhang Yi and Jun Wu and Xiuyuan Xu},
  title = {{Glance Before You Tell: Anomaly-Guided 3D Radiology Report Generation with Heat-Conduction Slice Encoders}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=p124P8VSQH},
}
Figure