Probabilistic 3D Surface Reconstruction from Sparse MRI Information

Katarína Tóthová, Sarah Parisot, Matthew C. H. Lee, Esther Puyol-Antón, Andrew P. King, Marc Pollefeys, Ender Konukoglu

Introduction

In clinical cardiac imaging, acquiring high-resolution 3D MRI volumes is often impractical due to time constraints and patient motion. Instead, clinicians typically acquire a sparse set of 2D slices. Reconstructing a complete 3D surface, such as the left ventricle myocardium, from these limited views is a significant challenge. Existing deep learning approaches often struggle with maintaining spatial context in world coordinates, managing the memory demands of high-resolution 3D volumes, and providing estimates of prediction uncertainty.

Methodology

The proposed framework addresses these challenges by combining a statistical shape model with a deep probabilistic neural network.

Overview of the probabilistic 3D surface reconstruction architecture. Input slices are processed by parallel CNN branches with coordinate maps, leading to a probabilistic latent space that generates PCA weights for surface reconstruction.

Spatially Aware CNNs

A key innovation is the use of "spatially aware" coordinate maps. Each input slice is concatenated with its 3D world coordinates before being fed into a CNN branch. This allows the network to learn the relative orientation and position of slices without requiring pre-alignment to a canonical space.

PCA Shape Prior and Probabilistic Latent Space

To ensure anatomically plausible reconstructions, the network predicts weights for a Linear Principal Component Analysis (PCA) model rather than raw vertex positions. The model is probabilistic: it outputs a mean ($\mu$) and a covariance matrix ($\Sigma$) for the PCA scores. This formulation allows for sampling multiple plausible surfaces, effectively quantifying the model's uncertainty.

Experimental Results

The model was evaluated on the UK Biobank cardiac MR dataset, using three quasi-orthogonal slices to reconstruct the left ventricle.

Quantitative comparison of the proposed probabilistic PCA method against deterministic baselines and volumetric autoencoders.

As shown in the results table, the probabilistic approach (prob PCA) consistently outperformed state-of-the-art methods like REC-CVAE and deterministic PCA across several metrics. Notably, it achieved superior performance in Average Symmetric Surface Distance (ASSD) and Hausdorff Distance (HD). Furthermore, the model showed exceptional accuracy in volume preservation, as indicated by the low Relative Absolute Volume Difference (RAVD).

Discussion and Conclusion

The integration of a PCA prior acts as a "safety net," ensuring that even in the absence of strong image evidence, the model produces anatomically valid shapes. The probabilistic nature of the model also enables the generation of uncertainty heatmaps, which show that confidence is highest near the input slices and decreases in unobserved regions.

While the current use of linear PCA is robust, future work may explore non-linear shape models to capture more complex anatomical variations. Additionally, while demonstrated on cardiac data, the framework is generalizable to other organs and sparse imaging protocols.

Summary updated

BibTeX
@inproceedings{tothova2020probabilistic,
  author = {Katarína Tóthová and Sarah Parisot and Matthew C. H. Lee and Esther Puyol-Antón and Andrew P. King and Marc Pollefeys and Ender Konukoglu},
  title = {{Probabilistic 3D Surface Reconstruction from Sparse MRI Information}},
  booktitle = {International Conference on Medical Image Computing and Computer-Assisted Intervention},
  year = {2020},
  url = {https://openreview.net/forum?id=8DKH6YyM_Q},
}
Figure