NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions
Andrew P. King

Andrew P. King

King's College London
5 previous affiliations
    • Professor of Medical Image Analysis · Since 2024
    • Full Professor · Since 2023
    • Reader in Medical Image Analysis · 2018–2024
    • Associate Professor · 2014–2018
    • Lecturer · 2011–2014
    • Postgraduate certificate, Academic practice · 2010–2012
    • Research Fellow · 1998–2001
  • HiLCoE College of Computer Science and Technology2005–2006
    • Assistant Professor · 2005–2006
  • Mekelle University2001–2005
    • Assistant Professor · 2001–2005
    • Doctor of Philosophy (Ph.D.), Computer Science · 1992–1996
  • Software Sciences Ltd1989–1991
    • Computer Programmer · 1989–1991
40Machine learning papers tracked by Lacuna
Is this you?

Research Overview

Andrew P. King focuses on medical image analysis, developing computational methods for motion correction, image reconstruction, and anatomical segmentation. His trajectory spans from manifold alignment techniques for dynamic MRI to semi-supervised learning strategies that address data scarcity in clinical settings. Recently, his focus has expanded to include score-based generative models for high-fidelity positron emission tomography reconstruction and robust echocardiography segmentation.

Research Trajectory

In the mid-2010s, King’s research primarily addressed the challenges of motion and alignment in dynamic medical imaging. A central problem in free-breathing magnetic resonance imaging is the degradation of image quality due to respiratory and cardiac motion. As senior author, King led research into retrospective self-gating methods to mitigate these artifacts. This work is exemplified by High-Resolution Self-Gated Dynamic Abdominal MRI Using Manifold Alignment, which utilized a radial golden-angle acquisition trajectory combined with manifold alignment. By embedding $k$-space radial profiles into a common low-dimensional manifold, the method extracted a multidimensional self-gating signal that allowed for accurate motion representation without the need for external sensors.

This interest in alignment naturally extended to multi-modal contexts, intersecting with the broader research direction of Information Theoretic Alignment for Multimodal Image Registration. In PET-MR respiratory signal estimation using semi-supervised manifold alignment, King’s group developed a data-driven dimensionality-reduction technique to align manifolds formed from both positron emission tomography (PET) and MR data. This approach was specifically designed to produce robust respiratory signals even in scenarios where MR data is temporarily unavailable, accommodating the realities of clinical PET-MR workflows.

By the late 2010s, King’s trajectory expanded to incorporate deep learning, with a particular emphasis on overcoming the scarcity of expertly annotated medical data. As principal investigator, he directed work on Quality-Aware Semi-supervised Learning for CMR Segmentation. Recognizing that standard semi-supervised learning (SSL) can sometimes degrade model performance by incorporating poor pseudo-labels, this research introduced a quality-aware framework. The method integrated prior biophysical and physiological knowledge to evaluate and filter unlabelled examples, thereby improving the reliability of cardiac magnetic resonance (CMR) segmentation.

During this period, King also contributed to the area of Spatial Registration for Computer Assisted Interventions and 3D anatomical modeling. He was a collaborating author on Probabilistic 3D Surface Reconstruction from Sparse MRI Information, which introduced a probabilistic deep learning approach capable of generating high-resolution 3D surface models from sparse 2D MR slices while simultaneously evaluating prediction uncertainty.

Moving into the 2020s, King’s research has increasingly focused on the robustness and clinical translation of deep learning models across heterogeneous environments. In Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial Labelling, his team addressed the domain shifts that occur when models are trained across diverse clinical datasets featuring different scanners and operator expertise levels. The proposed label dropout technique enabled effective training on partially labelled, multi-institutional data, improving the generalization of echocardiography segmentation.

Most recently, King has participated in advancing image reconstruction through generative artificial intelligence. He contributed to Likelihood-Scheduled Score-Based Generative Modeling for Fully 3D PET Image Reconstruction, which leverages pre-trained score-based generative models (SGMs) to solve inverse problems in medical imaging. This work demonstrated that SGMs could improve contrast recovery and resilience to different scanner setups in 3D PET imaging compared to traditional deep-learned reconstruction methods.

Current Directions

The most recent papers in the evidence indicate a strong focus on integrating advanced generative AI into medical image reconstruction pipelines. Recent work investigates the use of score-based generative models and supervised diffusion models for fully 3D PET imaging. These approaches aim to overcome the limitations of earlier deep-learned reconstructions by explicitly modeling the interaction between the generative prior and noisy measurement data, ensuring strict adherence to PET's Poisson likelihood model while accommodating varying scanner geometries.

Additionally, King continues to lead research in robust medical image segmentation. A major ongoing theme is the development of training strategies—such as label dropout—that allow neural networks to learn effectively from multi-institutional datasets characterized by domain shift and partial or missing annotations. This direction reflects a broader commitment to ensuring that automated measurement tools for modalities like echocardiography are reliable enough for widespread clinical deployment.

Profile updated

See something wrong? Report a mistake