Modified U-Net (mU-Net) with Incorporation of Object-Dependent High Level Features for Improved Liver and Liver-Tumor Segmentation in CT Images

Hyunseok Seo, Charles W. Huang, Maxime Bassenne, Ruoxiu Xiao, Lei Xing

Abstract

Segmentation of livers and liver tumors is a critical step in radiation therapy for hepatocellular carcinoma. However, automatic segmentation remains challenging due to low tissue contrast and the deformable nature of these structures in CT images. While the standard U-Net architecture is widely used, it suffers from information duplication, edge uncertainty, and the "pooling paradox" where small objects lose spatial information. This paper proposes the mU-Net (Modified U-Net), which introduces a residual path with deconvolution and activation operations into the skip connections. This architecture adaptively extracts high-level global features for small objects and high-resolution edge information for large objects. Evaluated on the Liver Tumor Segmentation (LiTS) challenge dataset, the mU-Net outperforms state-of-the-art networks in both organ and lesion segmentation.

Introduction

Automatic segmentation of the liver and its associated tumors is a "holy grail" in radiation therapy planning. Despite the success of deep learning models like the U-Net, three major architectural flaws persist:

  1. Information Duplication: Skip connections often pass redundant low-resolution information, leading to blurred feature maps.
  2. Edge Uncertainty: High-level features often lack the crisp, high-resolution edge information required for precise boundary definition.
  3. The Pooling Paradox: Large objects require significant pooling for global context, but the same pooling can cause the spatial information of small objects (like early-stage tumors) to vanish.

Methodology

The mU-Net transforms the passive skip connection of the standard U-Net into an active, adaptive component. The core innovation is the Residual Path, which replaces simple identity mapping with deconvolution and activation operations.

Schematic of the mU-Net architecture modifications. (a) Standard skip connection. (b) Blocked path for small objects. (c) Residual path with deconvolution. (d) Object-dependent filtering mechanism.

As shown in the architecture diagram, the network employs Object-Dependent Filtering. For large objects, the skip connection is restricted to high-resolution edge information to avoid blurring. Conversely, for small objects, the network can effectively "block" certain paths to allow full-resolution features to pass through, preventing the vanishing effect caused by successive pooling layers. Additional convolution layers within the skip connections further extract high-level global features specifically for small inputs.

Permeation Rate Analysis

The adaptive nature of the mU-Net is governed by a "permeation rate" logic. This mechanism allows the network to decide which features are passed through the skip connections based on the size of the input object.

Permeation rates across four stages of the network as a function of object size, demonstrating adaptive filtering behavior.

Experimental results show that the permeation rate varies significantly across different stages of the network. This behavior confirms that the mU-Net successfully learns to prioritize different feature types (e.g., edges vs. global context) depending on whether it is processing a large organ like the liver or a tiny, low-contrast tumor.

Results and Discussion

The mU-Net was benchmarked against several state-of-the-art models, including H-DenseUNet, using the LiTS 2017 and 3Dircadb datasets.

  • Liver Segmentation (LiTS): The model achieved a Dice Similarity Coefficient (DSC) of 98.51% and a Volume of Error (VOE) of 3.07%.
  • Tumor Segmentation (LiTS): The model achieved a DSC of 89.72%, a significant improvement over baseline models that struggle with small lesions.
  • Generalization: On the 3Dircadb dataset, the model maintained high performance with a 96.01% DSC for the liver.

While the current 2D implementation is highly efficient (~1.14 seconds per slice), future work will explore 3D volume-by-volume training to better capture spatial relationships between slices and the use of Soft-Dice loss to further refine boundary precision. The mU-Net demonstrates that making skip connections "smarter" is a viable path toward precision medical image analysis.

Summary updated

Abstract

Segmentation of livers and liver tumors is one of the most important steps in radiation therapy of hepatocellular carcinoma. The segmentation task is often done manually, making it tedious, labor intensive, and subject to intra-/inter- operator variations. While various algorithms for delineating organ-at-risks (OARs) and tumor targets have been proposed, automatic segmentation of livers and liver tumors remains intractable due to their low tissue contrast with respect to the surrounding organs and their deformable shape in CT images. The U-Net has gained increasing popularity recently for image analysis tasks and has shown promising results. Conventional U-Net architectures, however, suffer from three major drawbacks. To cope with these problems, we added a residual path with deconvolution and activation operations to the skip connection of the U-Net to avoid duplication of low resolution information of features. In the case of small object inputs, features in the skip connection are not incorporated with features in the residual path. Furthermore, the proposed architecture has additional convolution layers in the skip connection in order to extract high level global features of small object inputs as well as high level features of high resolution edge information of large object inputs. Efficacy of the modified U-Net (mU-Net) was demonstrated using the public dataset of Liver tumor segmentation (LiTS) challenge 2017. The proposed mU-Net outperformed existing state-of-art networks.
BibTeX
@article{seo2020modified,
  author = {Hyunseok Seo and Charles W. Huang and Maxime Bassenne and Ruoxiu Xiao and Lei Xing},
  title = {{Modified U-Net (mU-Net) with Incorporation of Object-Dependent High Level Features for Improved Liver and Liver-Tumor Segmentation in CT Images}},
  journal = {IEEE Trans. Medical Imaging},
  year = {2020},
  url = {https://openreview.net/forum?id=S48GgUCFzy},
}
Figure