Modified U-Net (mU-Net) With Incorporation of Object-Dependent High Level Features for Improved Liver and Liver-Tumor Segmentation in CT Images

Hyunseok Seo, Charles W. Huang, Maxime Bassenne, Ruoxiu Xiao, Lei Xing

TL;DR

The mU-Net (Modified U-Net) improves medical image segmentation by redesigning the standard U-Net skip connection into an adaptive "residual path." By incorporating object-dependent upsampling and additional convolution layers, the architecture effectively preserves high-resolution edge details for large organs while preventing the loss of spatial information for tiny tumors, outperforming existing state-of-the-art models on benchmark CT datasets.

What Problem Does This Paper Address?

Automatic segmentation of the liver and its tumors in CT scans is a "holy grail" in radiation therapy planning, yet it remains notoriously difficult. Livers have highly deformable shapes, and tumors often exhibit poor contrast against surrounding healthy tissue.

While the standard U-Net is the industry workhorse for this task, the authors identify three critical flaws in its architecture:

  1. Information Duplication: Skip connections often pass redundant low-resolution information, which can lead to blurred feature maps.
  2. Edge Uncertainty: High-level features often lack the crisp, high-resolution edge information needed to define precise boundaries.
  3. The Pooling Paradox: It is difficult to optimize the number of pooling operations. Large objects need more pooling for global context, but the same pooling can cause the spatial information of small objects (like early-stage tumors) to vanish entirely.

Methods

The authors introduce the mU-Net, which transforms the passive skip connection into an active, adaptive component. Key innovations include:

  • The Residual Path: Instead of a simple identity mapping, the mU-Net places a residual path (consisting of deconvolution and activation) directly after the pooling layers. This path acts as a filter that adaptively decides which features to pass.
  • Object-Dependent Upsampling: The network uses a "permeation rate" logic. For large objects, the skip connection is restricted to high-resolution edge information to avoid blurring. For small objects, the network effectively "blocks" the deconvolution path to allow full-resolution features to pass through, preventing the "vanishing" effect caused by pooling.
  • Additional Convolution Layers: Extra layers are added within the skip connections to extract higher-level global features specifically for small inputs, ensuring they aren't treated as mere noise.

Datasets

The model was trained and validated on two major public benchmarks:

  1. LiTS (Liver Tumor Segmentation Challenge 2017): 130 training CT scans and 35 test scans. This is a standard benchmark for evaluating both organ and lesion segmentation.
  2. 3Dircadb (3D Image Reconstruction for Comparison of Algorithm Database): Used as an additional validation set to ensure the model generalizes across different data sources.

Key Insights and Ideas

  • Skip Connections Should Be Smart: In a standard U-Net, skip connections are "dumb"—they pass everything. The mU-Net treats them as an optimization problem, where the network learns to filter out redundant low-frequency data.
  • Preserving Small Objects: The "aha moment" here is the realization that small tumors are often destroyed by the very pooling layers meant to help the network understand the larger liver. By providing a "shortcut" that preserves resolution for small objects, the mU-Net maintains high sensitivity for tiny lesions.
  • Edge-First Feature Extraction: For large organs, the network prioritizes edge-like information in the skip connection. This prevents the "smoothing" effect that often plagues U-Net outputs, leading to much sharper contours in the final segmentation.

Key Results

The mU-Net was compared against several heavyweights, including H-DenseUNet and pyramid-pooling networks.

  • Liver Segmentation (LiTS): Achieved a Dice Similarity Coefficient (DSC) of 98.51% and a Volume of Error (VOE) of only 3.07%.
  • Tumor Segmentation (LiTS): Achieved a DSC of 89.72%, significantly outperforming baseline models which struggled with small, low-contrast tumors.
  • Generalization (3Dircadb): Maintained strong performance with a 96.01% DSC for the liver and 68.14% for tumors.
  • Efficiency: Despite the added complexity, the mU-Net maintains a competitive evaluation time (~1.14 seconds per slice), making it viable for clinical workflows.

Limitations and Future Work

The authors highlight a few areas for improvement:

  • Loss Function: The study used Mean Square Error (MSE) for speed, but the authors admit that Soft-Dice loss might better capture structural similarities and further improve boundary precision.
  • 2D vs. 3D: Due to memory constraints, the model was trained slice-by-slice (2D). Moving to a full volume-by-volume (3D) training approach could help the network learn better spatial relationships between slices.
  • Generalizability: Like most deep learning models, there is a risk of performance drop-off when applied to CT scanners or protocols not represented in the training set. Future work involves testing the architecture on other modalities like MRI and PET.

Summary updated

Abstract

Segmentation of livers and liver tumors is one of the most important steps in radiation therapy of hepatocellular carcinoma. The segmentation task is often done manually, making it tedious, labor intensive, and subject to intra-/inter- operator variations. While various algorithms for delineating organ-at-risks (OARs) and tumor targets have been proposed, automatic segmentation of livers and liver tumors remains intractable due to their low tissue contrast with respect to the surrounding organs and their deformable shape in CT images. The U-Net has gained increasing popularity recently for image analysis tasks and has shown promising results. Conventional U-Net architectures, however, suffer from three major drawbacks. First, skip connections allow for the duplicated transfer of low resolution information in feature maps to improve efficiency in learning, but this often leads to blurring of extracted image features. Secondly, high level features extracted by the network often do not contain enough high resolution edge information of the input, leading to greater uncertainty where high resolution edge dominantly affects the network’s decisions such as liver and liver-tumor segmentation. Thirdly, it is generally difficult to optimize the number of pooling operations in order to extract high level global features, since the number of pooling operations used depends on the object size. To cope with these problems, we added a residual path with deconvolution and activation operations to the skip connection of the U-Net to avoid duplication of low resolution information of features. In the case of small object inputs, features in the skip connection are not incorporated with features in the residual path. Furthermore, the proposed architecture has additional convolution layers in the skip connection in order to extract high level global features of small object inputs as well as high level features of high resolution edge information of large object inputs. Efficacy of the modified U-Net (mU-Net) was demonstrated using the public dataset of Liver tumor segmentation (LiTS) challenge 2017. For liver-tumor segmentation, Dice similarity coefficient (DSC) of 89.72 %, volume of error (VOE) of 21.93 %, and relative volume difference (RVD) of − 0.49 % were obtained. For liver segmentation, DSC of 98.51 %, VOE of 3.07 %, and RVD of 0.26 % were calculated. For the public 3D Image Reconstruction for Comparison of Algorithm Database (3Dircadb), DSCs were 96.01 % for the liver and 68.14 % for liver-tumor segmentations, respectively. The proposed mU-Net outperformed existing state-of-art networks.
BibTeX
@article{seo2020modified,
  author = {Hyunseok Seo and Charles W. Huang and Maxime Bassenne and Ruoxiu Xiao and Lei Xing},
  title = {{Modified U-Net (mU-Net) With Incorporation of Object-Dependent High Level Features for Improved Liver and Liver-Tumor Segmentation in CT Images}},
  journal = {IEEE Trans. Medical Imaging},
  year = {2020},
  url = {https://openreview.net/forum?id=S48GgUCFzy},
}

Loading related content...

Figure