Measurement of high-pressure xenon gas absorption in acrylic

H. Lin, Kai Ni, Hui Du, K. Han, Xiangdong Ji, T. Li, Limin Luo, Shangguang Wang, X. Yan, Xiaoqin Zeng, W. ZhangJournal of Instrumentation 2022 · DOI · arXiv

Abstract

Acrylic is a popular structural material in experiments requiring low background because of its radio-purity, machinability, and mechanical strength. However, its porosity may cause significant gas absorption and influence the detector stability in the long term. The interaction between acrylic and other detector materials becomes one of the key concerns in the detector design. In this paper, we carry out an experiment to measure quantitatively the absorption process of high-pressure xenon gas into acrylic. A specific setup is designed for the measurement, and systematic measurements are done to obtain a result of the absorption amount: 0.98 g xenon into 332 g of acrylic.

Introduction

In the search for rare physical phenomena, such as dark matter or neutrinoless double beta decay, detector materials must exhibit extreme radio-purity. Poly(methyl methacrylate), or acrylic, is widely utilized in experiments like PandaX-III and NEXT due to its structural integrity and low radioactive background. However, acrylic is known to be physically active, capable of absorbing up to 0.4% water by weight, leading to significant outgassing.

A critical concern for high-pressure xenon (HPXe) detectors is whether acrylic absorbs xenon gas. If xenon migrates into the plastic, it could alter gas density, compromise detector stability, or trap radioactive impurities. This study quantifies the absorption of xenon into acrylic at high pressure over an extended period.

Experimental Methods

The research team developed a dedicated high-pressure system to monitor xenon absorption using two independent techniques: the pressure drop method and the gravimetric method.

Pressure Drop Method

Two identical stainless steel chambers were used: C1 contained the acrylic samples, while C2 served as an empty reference. Both were filled with xenon to approximately 11 bar. Pressure and temperature were monitored for 142 days. To ensure accuracy at high pressures, the virial equation of state was employed to calculate the gas mass, correcting for temperature fluctuations.

Schematic of the high-pressure xenon absorption measurement system, featuring sample chambers (1, 2) and pressure sensors (4, 5, 6).

Gravimetric Method

Acrylic samples (totaling 332 g) were weighed before and after the 142-day exposure using high-precision analytical balances. To account for ambient moisture absorption during weighing, six different batches were used for cross-validation. The study also compared two geometries: Stack A (thin plates, high surface area) and Stack B (thick plates, low surface area) to distinguish between surface-driven and diffusion-driven absorption.

Results and Discussion

The experimental data revealed a continuous absorption process that did not reach saturation within the 142-day window.

Pressure and temperature trends over 140 days. The red line shows the temperature-corrected pressure in the sample chamber (C1) steadily decreasing, while the reference chamber (C2, blue line) remains stable.

Quantitative Findings

  • Total Absorption: The pressure drop method measured an absorption of $0.98^{+0.15}_{-0.04}$ g of xenon into 332 g of acrylic.
  • Weight Confirmation: The gravimetric method yielded a consistent result of approximately 0.90 g.
  • Absorption Rate: By the end of the run, xenon was still being absorbed at a rate of roughly 0.01 g/day.
  • Surface Area Effects: Comparison between the two stacks indicated that absorption initially correlates more strongly with surface area than total mass. This suggests that the transition of xenon atoms from the gas phase into the polymer surface is the rate-limiting step compared to internal diffusion.

Detector Stability

The reference chamber (C2) remained stable throughout the experiment, confirming that the observed pressure drop in C1 was due to absorption rather than leaks or sensor drift. For large-scale experiments like PandaX-III, which utilize roughly 350 kg of acrylic, these results suggest a potential loss of ~70 g of xenon into the detector walls within the first six months.

Conclusion

This study provides the first quantitative measurement of high-pressure xenon absorption in acrylic. The findings highlight that acrylic acts as a "sink" for xenon, with absorption continuing long-term without reaching saturation. Future work should focus on longer-term studies to identify the ultimate saturation point and investigate the temperature dependence of this process, particularly at the cryogenic temperatures common in liquid xenon experiments.

Summary updated

Abstract

Abstract Acrylic is a popular structural material in experiments requiring low background because of its radio-purity, machinability, and mechanical strength. However, its porosity may cause significant gas absorption and influence the detector stability in the long term. The interaction between acrylic and other detector materials becomes one of the key concerns in the detector design. In this paper, we carry out an experiment to measure quantitatively the absorption process of high-pressure xenon gas into acrylic. A specific setup is designed for the measurement, and systematic measurements are done to obtain a result of the absorption amount: 0.98 g xenon into 332 g of acrylic.
BibTeX
@article{lin2022measurement,
  author = {H. Lin and Kai Ni and Hui Du and K. Han and Xiangdong Ji and T. Li and Limin Luo and Shangguang Wang and X. Yan and Xiaoqin Zeng and W. Zhang},
  title = {{Measurement of high-pressure xenon gas absorption in acrylic}},
  journal = {Journal of Instrumentation},
  year = {2022},
  doi = {10.1088/1748-0221/17/05/p05027},
}
Figure