MADCrowner: Margin Aware Dental Crown Design with Template Deformation and Refinement
Abstract
Dental crown restoration is one of the most common treatment modalities for tooth defect, where personalized dental crown design is critical. While computer-aided design (CAD) systems have notably enhanced the efficiency of dental crown design, extensive manual adjustments are still required in the clinic workflow. Recent studies have explored the application of learning-based methods for the automated generation of restorative dental crowns. Nevertheless, these approaches were challenged by inadequate spatial resolution, noisy outputs, and overextension of surface reconstruction. To address these limitations, we propose \totalframework, a margin-aware mesh generation framework comprising CrownDeformR and CrownSegger. Inspired by the clinic manual workflow of dental crown design, we designed CrownDeformR to deform an initial template to the target crown based on anatomical context, which is extracted by a multi-scale intraoral scan encoder. Additionally, we introduced \marginseg, a novel margin segmentation network, to extract the cervical margin of the target tooth. The performance of CrownDeformR improved with the cervical margin as an extra constraint. And it was also utilized as the boundary condition for the tailored postprocessing method, which removed the overextended area of the reconstructed surface. We constructed a large-scale intraoral scan dataset and performed extensive experiments. The proposed method significantly outperformed existing approaches in both geometric accuracy and clinical feasibility.
Empirical ResultsBrowse all benchmarks →
| Benchmark | Method | Metric | Score | Protocol / Evidence |
|---|---|---|---|---|
| Dental crown generation · in mesh | MADCrowner (row: Ours) | Hausdorff Distance | 1.046 mm | Dental Crown GenerationSource quoteL511: 1.096 │ 1.026 │ 1.046 |
| Dental crown generation · in mesh | MADCrowner (row: Ours) | F-score | 0.917 | Dental Crown GenerationSource quoteL512: 0.907 │ 0.920 │ 0.917 |
| Dental crown generation · on generated point clouds | MADCrowner | HDF distance | 1.027 mm | Dental Crown GenerationSource quoteL349: The experimental results are listed in \autoref{tab:performance_comparison}. MADCrowner~achieved the best performance across all the metrics. Specifically, our method surpassed the second-highest performance in CD-L2, fidelity distance, and F-score by 29.2%, 26.4%, and 3.36%, respectively. This demonstrates that MADCrowner~significantly enhanced the consistency between the generated dental crowns and the ground truth. In terms of HDF distance, our method achieved a significant improvement by reducing the best performance from 1.139 mm to 1.027 mm. This notable reduction in HDF distance indicates that our approach generated dental crowns with less noise and lower deviation from the ground truth. |
BibTeX
@article{wei2026madcrowner,
author = {Linda Wei and Chang Liu and Wenran Zhang and Yuxuan Hu and Ruiyang Li and Feng Qi and Changyao Tian and Ke Wang and Yuanyuan Wang and Shaoting Zhang and Dimitris Metaxas and Hongsheng Li},
title = {{MADCrowner: Margin Aware Dental Crown Design with Template Deformation and Refinement}},
journal = {Medical Image Analysis},
year = {2026},
doi = {10.1016/j.media.2026.104113},
}Ask Althea to put this paper to the test.
Loading related content...