Dental crown generation
2 papers · 6 extracted observations · dental crown generation · Markdown · CSV · JSON API
Also indexed as: dental-crown-generation
Showing 6 of 6 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | MADCrowner (row: Ours) proposed | Hausdorff Distance | 1.046 mm | Dental Crown Generation | MADCrowner: Margin Aware Dental Crown Design with Template Deformation and RefinementSource quoteL511: 1.096 │ 1.026 │ 1.046 |
| 2026 | MADCrowner (row: Ours) proposed | F-score | 0.917 | Dental Crown Generation | MADCrowner: Margin Aware Dental Crown Design with Template Deformation and RefinementSource quoteL512: 0.907 │ 0.920 │ 0.917 |
| 2026 | MADCrowner proposed | HDF distance | 1.027 mm | Dental Crown Generation | MADCrowner: Margin Aware Dental Crown Design with Template Deformation and RefinementSource quoteL349: The experimental results are listed in \autoref{tab:performance_comparison}. MADCrowner~achieved the best performance across all the metrics. Specifically, our method surpassed the second-highest performance in CD-L2, fidelity distance, and F-score by 29.2%, 26.4%, and 3.36%, respectively. This demonstrates that MADCrowner~significantly enhanced the consistency between the generated dental crowns and the ground truth. In terms of HDF distance, our method achieved a significant improvement by reducing the best performance from 1.139 mm to 1.027 mm. This notable reduction in HDF distance indicates that our approach generated dental crowns with less noise and lower deviation from the ground truth. |
| 2023 | Proposed transformer-based crown generation, with margin line information proposed non-standard slice | Average distance | 372.2782 μm | Dental Crown Generation · margin-line-information=with | Improving the quality of dental crown using a Transformer-based methodSource quoteL100: 372.2782 |
| 2023 | Proposed transformer-based crown generation, without margin line information ablation non-standard slice | Average distance | 2105.3221 μm | Dental Crown Generation · margin-line-information=without | Improving the quality of dental crown using a Transformer-based methodSource quoteL99: 2105.3221 |
| 2023 | Proposed transformer-based crown generation, without margin line information ablation non-standard slice | max distance | 3501.1311 μm | Dental Crown Generation · margin-line-information=without | Improving the quality of dental crown using a Transformer-based methodSource quoteL94: 3501.1311 |