MADCrowner: Margin Aware Dental Crown Design with Template Deformation and Refinement

Linda Wei, Chang Liu, Wenran Zhang, Yuxuan Hu, Ruiyang Li, Feng Qi, Changyao Tian, Ke Wang, Yuanyuan Wang, Shaoting Zhang, Dimitris Metaxas, Hongsheng Li · DOI

Abstract

Dental crown restoration is one of the most common treatment modalities for tooth defect, where personalized dental crown design is critical. While computer-aided design (CAD) systems have notably enhanced the efficiency of dental crown design, extensive manual adjustments are still required in the clinic workflow. Recent studies have explored the application of learning-based methods for the automated generation of restorative dental crowns. Nevertheless, these approaches were challenged by inadequate spatial resolution, noisy outputs, and overextension of surface reconstruction. To address these limitations, we propose MADCrowner, a margin-aware mesh generation framework comprising CrownDeformR and CrownSegger. Inspired by the clinic manual workflow of dental crown design, we designed CrownDeformR to deform an initial template to the target crown based on anatomical context, which is extracted by a multi-scale intraoral scan encoder. Additionally, we introduced CrownSegger, a novel margin segmentation network, to extract the cervical margin of the target tooth. The performance of CrownDeformR improved with the cervical margin as an extra constraint. And it was also utilized as the boundary condition for the tailored postprocessing method, which removed the overextended area of the reconstructed surface. We constructed a large-scale intraoral scan dataset and performed extensive experiments. The proposed method significantly outperformed existing approaches in both geometric accuracy and clinical feasibility.

Introduction

In restorative dentistry, designing a crown is a meticulous process. Even with modern Computer-Aided Design (CAD) software, a technician often spends 15 to 60 minutes manually adjusting a digital template to ensure it fits the patient's unique anatomy and aligns perfectly with the "cervical margin"—the critical boundary where the crown meets the prepared tooth stub.

MADCrowner is a novel AI framework that automates this design process by deforming standard tooth templates to fit patient-specific intraoral scans. By prioritizing the cervical margin, the system produces clinically feasible, high-fidelity meshes in under a second, addressing common issues in previous deep learning methods such as information loss from 2D projections, noisy geometry, and the "watertight" problem where meshes are overextended and require manual trimming.

Methodology

MADCrowner mimics the manual clinical workflow through a two-stage pipeline consisting of CrownSegger and CrownDeformR.

Overview of the MADCrowner framework, illustrating the pipeline from input intraoral scan (IOS) to the final generated crown.

CrownSegger and Margin Extraction

CrownSegger is a hybrid point-voxel segmentation network. It identifies the "abutment" (the prepared tooth stub) from an intraoral scan (IOS) and extracts the precise cervical margin line. This margin serves as a critical anchor for the subsequent deformation and post-processing steps, ensuring the crown fits the base of the tooth perfectly.

The cervical margin extraction process, identifying the precise boundary on the prepared tooth to guide crown fitting.

CrownDeformR

Instead of generating a crown from a vacuum, CrownDeformR takes a standard tooth template and deforms it to fit the patient's anatomy. It utilizes Transformer-based modules:

  • Geometry Aware Transformers (GAT): Capture local 3D structures.
  • Cross-Attention Transformers (CAT): Align template features with patient-specific scan data.

Surface Reconstruction and Post-processing

The system employs Differentiable Poisson Surface Reconstruction (DPSR) to create a smooth mesh. A tailored post-processing method then uses the margin identified by CrownSegger to "excise" the superfluous bottom of the watertight mesh, resulting in an open, genus-zero mesh ready for clinical use. A specialized Curvature and Margin Penalty Loss (CMPL) ensures high fidelity in critical areas like grooves and boundaries.

Experimental Setup

The authors curated a large-scale dataset of 4,602 patient cases, each including a raw intraoral scan and a ground truth crown designed by a professional. The dataset covers all premolars and molars, with point-wise annotations distinguishing the prepared abutment from neighboring structures.

Results and Discussion

MADCrowner sets a new state-of-the-art in automated dental design:

  • Geometric Accuracy: Outperformed previous leading methods (e.g., DMCv2) by 29.2% in Chamfer Distance and 26.4% in fidelity distance.
  • Clinical Fit: Demonstrated the lowest error in proximal contact analysis, crucial for preventing food impaction and periodontal issues.
  • Efficiency: The model runs in approximately 600ms on standard hardware, requiring only 1.1 GB of VRAM, making it highly suitable for clinical deployment.

Limitations

While highly effective, the model occasionally produces "smoothed average" results due to regression-based losses, potentially losing fine anatomical details like deep occlusal grooves. Performance on incisors and canines is also slightly lower due to data imbalance. Future work may explore generative models like Diffusion Models to provide multiple design options for aesthetic preference.

Conclusion

MADCrowner successfully bridges the gap between automated AI generation and clinical feasibility in dental restoration. By focusing on template deformation and precise margin extraction, it offers a robust, efficient solution for personalized crown design.

Summary updated

Abstract

Dental crown restoration is one of the most common treatment modalities for tooth defect, where personalized dental crown design is critical. While computer-aided design (CAD) systems have notably enhanced the efficiency of dental crown design, extensive manual adjustments are still required in the clinic workflow. Recent studies have explored the application of learning-based methods for the automated generation of restorative dental crowns. Nevertheless, these approaches were challenged by inadequate spatial resolution, noisy outputs, and overextension of surface reconstruction. To address these limitations, we propose \totalframework, a margin-aware mesh generation framework comprising CrownDeformR and CrownSegger. Inspired by the clinic manual workflow of dental crown design, we designed CrownDeformR to deform an initial template to the target crown based on anatomical context, which is extracted by a multi-scale intraoral scan encoder. Additionally, we introduced \marginseg, a novel margin segmentation network, to extract the cervical margin of the target tooth. The performance of CrownDeformR improved with the cervical margin as an extra constraint. And it was also utilized as the boundary condition for the tailored postprocessing method, which removed the overextended area of the reconstructed surface. We constructed a large-scale intraoral scan dataset and performed extensive experiments. The proposed method significantly outperformed existing approaches in both geometric accuracy and clinical feasibility.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
Dental crown generation · in meshMADCrowner (row: Ours)Hausdorff Distance1.046 mmDental Crown Generation
Source quote
L511: 1.096 │ 1.026 │ 1.046
Dental crown generation · in meshMADCrowner (row: Ours)F-score0.917Dental Crown Generation
Source quote
L512: 0.907 │ 0.920 │ 0.917
Dental crown generation · on generated point cloudsMADCrownerHDF distance1.027 mmDental Crown Generation
Source quote
L349: The experimental results are listed in \autoref{tab:performance_comparison}. MADCrowner~achieved the best performance across all the metrics. Specifically, our method surpassed the second-highest performance in CD-L2, fidelity distance, and F-score by 29.2%, 26.4%, and 3.36%, respectively. This demonstrates that MADCrowner~significantly enhanced the consistency between the generated dental crowns and the ground truth. In terms of HDF distance, our method achieved a significant improvement by reducing the best performance from 1.139 mm to 1.027 mm. This notable reduction in HDF distance indicates that our approach generated dental crowns with less noise and lower deviation from the ground truth.
BibTeX
@article{wei2026madcrowner,
  author = {Linda Wei and Chang Liu and Wenran Zhang and Yuxuan Hu and Ruiyang Li and Feng Qi and Changyao Tian and Ke Wang and Yuanyuan Wang and Shaoting Zhang and Dimitris Metaxas and Hongsheng Li},
  title = {{MADCrowner: Margin Aware Dental Crown Design with Template Deformation and Refinement}},
  journal = {Medical Image Analysis},
  year = {2026},