NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

m1: Unleash the Potential of Test-Time Scaling for Medical Reasoning with Large Language Models

Xiaoke Huang, Juncheng Wu, Hui Liu, Xianfeng Tang, Yuyin Zhou · DOI

Researchers from UC Santa Cruz and Amazon Research have introduced m1, a novel approach exploring whether the "thinking" paradigm—popularized by models like OpenAI’s o1—can be effectively translated to the medical domain. Unlike mathematical reasoning, which relies heavily on symbolic logic, medical reasoning requires a delicate balance of logical deduction and the accurate recall of vast, specialized knowledge.

The Challenge of Medical Reasoning

While Large Language Models (LLMs) have demonstrated significant gains in math and coding through "test-time scaling" (allowing the model more time/tokens to process a solution), the medical field presents a unique set of hurdles. Medical tasks often involve multi-step clinical decision-making where a single missing fact can render a long chain of thought useless. Existing medical LLMs typically address this through computationally intensive Reinforcement Learning (RL). The m1 project investigates whether a lightweight, Supervised Fine-Tuning (SFT) approach can unlock similar expert-level reasoning in open-source models.

Methodology: The m1 Pipeline

The development of the m1 series (7B and 32B models) followed a rigorous data curation and training pipeline designed to maximize reasoning quality while maintaining efficiency.

The m1 data curation and model training pipeline, illustrating the transition from 196K raw QA pairs to a high-quality 23K reasoning dataset.
  1. Difficulty Filtering: Starting with 196K medical QA pairs, the team filtered for the 37K questions that a standard Qwen2.5 model could not solve, ensuring the training focused on challenging scenarios.
  2. Reasoning Generation: Using DeepSeek-R1, the researchers generated detailed, step-by-step reasoning traces for these difficult questions. Only traces resulting in the correct final answer (23K samples) were retained.
  3. Supervised Fine-Tuning (SFT): Qwen2.5-Instruct models were fine-tuned on this curated data. Notably, this approach avoids the complexity of RL, making it highly accessible for open-source development.
  4. Inference Control: The models utilize a "thinking budget" to manage token limits during inference, allowing for controlled test-time scaling.

The core finding of the study is that while test-time scaling significantly improves performance, it behaves differently in medicine than in logic-pure domains. Evaluation across nine benchmarks (including MedQA-USMLE, NEJM, and Lancet) revealed several key insights:

Accuracy across various medical benchmarks as a function of the thinking budget (number of tokens).
  • The 4K Sweet Spot: Accuracy generally improves as the thinking budget increases, but hits diminishing returns around 4,000 tokens. Beyond this point, models may "overthink," introducing logical errors or second-guessing correct initial intuitions.
  • The Knowledge Bottleneck: Unlike math, where solutions can often be derived from first principles, medical reasoning is limited by the model's internal knowledge base. If a model does not know a specific anatomical fact, additional thinking time cannot compensate for that missing information. Scaling enhances logic, but it cannot manufacture knowledge.
  • Budget Forcing: The researchers experimented with "budget forcing"—using a "Wait" token to prevent the model from answering too early. While helpful in some cases, it proved to be a double-edged sword in medicine, sometimes leading to unstable reasoning and the retrieval of faulty information.

Key Results and Performance

The m1 models demonstrate that inference-time compute can effectively substitute for raw parameter count.

  • m1-32B achieved performance levels comparable to 70B-parameter models, showcasing the efficiency of the test-time scaling approach.
  • m1-7B-23K established a new State-of-the-Art (SOTA) for models under 10B parameters, reaching an average accuracy of 60.32% across all evaluated benchmarks.

Conclusion and Future Directions

The m1 series proves that test-time scaling is a viable path for advancing medical AI without the need for massive RL frameworks. However, the "knowledge ceiling" remains the primary obstacle. Future work will likely focus on pairing these reasoning capabilities with Retrieval-Augmented Generation (RAG) to ground the model's "thinking" in external, verified medical databases, and developing specialized verifiers to mitigate the risks of overthinking.

Summary updated

BibTeX
@inproceedings{huang2025m,
  author = {Xiaoke Huang and Juncheng Wu and Hui Liu and Xianfeng Tang and Yuyin Zhou},
  title = {{m1: Unleash the Potential of Test-Time Scaling for Medical Reasoning with Large Language Models}},
  booktitle = {GenAI4Health @ NeurIPS},
  year = {2025},
  url = {https://openreview.net/forum?id=9l6unbTnQi},
}
Figure