Dual-Teacher++: Exploiting Intra-domain and Inter-domain Knowledge with Reliable Transfer for Cardiac Segmentation

Kang Li, Shujun Wang, Lequan Yu, Pheng-Ann Heng

Introduction

Deep learning has revolutionized medical image segmentation, yet its performance is heavily dependent on large-scale, high-quality expert annotations. In the medical domain, such labels are notoriously difficult and expensive to obtain. To mitigate this "annotation scarcity," researchers have turned to Semi-supervised Learning (SSL), which utilizes unlabeled data from the target modality, and Domain Adaptation (DA), which leverages labeled data from a different source modality.

This paper introduces Dual-Teacher++, a novel framework that synergistically combines SSL and DA. By concurrently exploiting inter-domain knowledge (cross-modality) and intra-domain knowledge (unlabeled target data), the framework achieves state-of-the-art performance in cardiac segmentation tasks.

Methodology

The Dual-Teacher++ framework employs a student-teacher architecture featuring two specialized teachers to guide a single student model.

Overview of the Dual-Teacher++ framework, illustrating the inter-domain and intra-domain knowledge transfer paths with reliability control.

Inter-domain Teacher

The Inter-domain Teacher focuses on labeled source domain data (e.g., MR images). To bridge the modality gap, an "Appearance Alignment" step using CycleGAN transforms source images to resemble the target domain (e.g., synthetic CT). The teacher learns from these aligned images and transfers knowledge to the student via distillation. To ensure quality, the GAN's discriminator acts as a reliability control, weighting synthetic samples so the student ignores unrealistic "hallucinations."

Intra-domain Teacher

The Intra-domain Teacher leverages unlabeled target domain data. It is updated using an Exponential Moving Average (EMA) of the student’s weights, providing stable targets for the student to mimic. To handle the inherent uncertainty in unlabeled data, the framework employs Monte Carlo Dropout to generate pixel-level uncertainty maps. This "reliability control" ensures the student only learns from high-confidence regions.

Experimental Results

The framework was evaluated on the MM-WHS 2017 challenge dataset, focusing on segmenting seven cardiac substructures.

Quantitative Performance

Dual-Teacher++ demonstrated significant improvements over baseline and existing state-of-the-art methods. In the MR-to-CT adaptation task:

  • Dice Score: Achieved 87.82%, a substantial increase from the supervised-only baseline of 72.75%.
  • Average Surface Distance (ASD): Reduced to 3.69 voxels, down from 10.13 in the baseline, indicating much higher boundary precision.

Qualitative Insights

Visual analysis confirmed that Dual-Teacher++ produces smoother, more anatomically accurate contours. It particularly excels at distinguishing between adjacent, visually similar structures like the pulmonary artery and the ascending aorta, which often confuse standard models.

Conclusion

Dual-Teacher++ effectively addresses the challenge of limited annotations by unifying cross-modality priors and unlabeled target data. The inclusion of reliability control mechanisms—using GAN discriminators for synthetic data and uncertainty maps for unlabeled data—is pivotal in preventing model degradation from noisy inputs. Future work may explore 3D implementations to further capture spatial context and extend the framework toward universal multi-modality adaptation.

Summary updated

BibTeX
@article{li2021dual,
  author = {Kang Li and Shujun Wang and Lequan Yu and Pheng-Ann Heng},
  title = {{Dual-Teacher++: Exploiting Intra-domain and Inter-domain Knowledge with Reliable Transfer for Cardiac Segmentation}},
  journal = {IEEE Trans. Medical Imaging},
  year = {2021},
  url = {https://openreview.net/forum?id=87YPcExl7W},
}
Figure