Batch Classification with Applications in Computer Aided Diagnosis

Volkan Vural, Glenn Fung, Balaji Krishnapuram, Jennifer G. Dy, R. Bharat Rao

Abstract

Most classification methods assume that the samples are drawn independently and identically from an unknown data generating distribution, yet this assumption is violated in several real life problems. In order to relax this assumption, we consider the case where batches or groups of samples may have internal correlations, whereas the samples from different batches may be considered to be uncorrelated. Two algorithms are developed to classify all the samples in a batch jointly, one based on a probabilistic analysis and another based on a mathematical programming approach. Experiments on three real-life computer aided diagnosis (CAD) problems demonstrate that the proposed algorithms are significantly more accurate than a naive SVM which ignores the correlations among the samples.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
pulmonary embolism (PE) datasetBatchSVMsensitivity80%+27 vs baselineMedical Image Detection · split: test · operating-point=6 false positives per patient/image
Source quote
L421: However, BatchSVM achieves 80% with a remarkable improvement (27%). BatchProb also outperformsSVM with a 64% sensitivity. As seen from the figure, the two proposed methods are substantially more accurate than standard SVMs at any specificity level.
pulmonary embolism (PE) datasetBatchProbsensitivity64%+11 vs baselineMedical Image Detection · split: test · operating-point=6 false positives per patient/image
Source quote
L421: However, BatchSVM achieves 80% with a remarkable improvement (27%). BatchProb also outperformsSVM with a 64% sensitivity. As seen from the figure, the two proposed methods are substantially more accurate than standard SVMs at any specificity level.
Colon Cancer DataBatchSVMsensitivity84%+29.5 vs baselineMedical Image Detection · split: test · operating-point=1 false positive per patient/image
Source quote
L423: Figure 3b. However, BatchSVM improved SVM’s performance to 84% sensitivity for the same number of false positives. Note that BatchProb improved the sensitivity further, giving 89.6% for the same specifity. In one to ten false positives region which constitutes the region of interest in our applications, our proposed methods outperform standard SVM significantly.
Colon Cancer DataBatchProbsensitivity89.6%+35.1 vs baselineMedical Image Detection · split: test · operating-point=1 false positive per patient/image
Source quote
L423: Figure 3b. However, BatchSVM improved SVM’s performance to 84% sensitivity for the same number of false positives. Note that BatchProb improved the sensitivity further, giving 89.6% for the same specifity. In one to ten false positives region which constitutes the region of interest in our applications, our proposed methods outperform standard SVM significantly.
Reported baseline / comparator measurements (2)
BenchmarkMethodMetricScoreProtocol / Evidence
pulmonary embolism (PE) datasetstandard SVM baselinesensitivity53%Medical Image Detection · split: test · operating-point=6 false positives per patient/image
Source quote
L420: In Figure 3a, corresponding to the comparison of the ROC curves on the PE dataset, we observe that standard SVM can only achieve 53% sensitivity for six false positives.
Colon Cancer Datastandard SVM baselinesensitivity54.5%Medical Image Detection · split: test · operating-point=1 false positive per patient/image
Source quote
L422: Colon cancer data is a relatively easier data set than pulmonary embolism since standard SVM can achieve 54.5% sensitivity at one false positive level as illustrated in