NeurIPS 2026Coming to NeurIPS in Sydney?Explore papers, orals & directions

Batch Classification with Applications in Computer Aided Diagnosis

Volkan Vural, Glenn Fung, Balaji Krishnapuram, Jennifer G. Dy, R. Bharat Rao

Abstract

In Computer Aided Diagnosis (CAD), standard machine learning models typically assume that data samples are Independent and Identically Distributed (IID). However, in medical imaging, multiple candidate regions identified within a single patient scan are often highly correlated due to spatial proximity or shared anatomical structures. This paper introduces "Batch Classification" algorithms—specifically BatchProb and BatchSVM—designed to jointly classify groups of samples. By leveraging these internal relationships, the proposed methods significantly enhance diagnostic accuracy for conditions such as pulmonary embolisms and lung nodules.

The Problem: The Failure of the IID Assumption

Most classification systems, including the traditional Support Vector Machine (SVM), treat every data point as an independent entity. In the context of CAD, a candidate generation algorithm might flag several overlapping or nearby regions on a lung scan. These regions often represent the same physical pathology, meaning their features and labels are deeply correlated.

Figure 1: Multiple candidate regions in a pulmonary embolism CT scan. These candidates are often spatially correlated, violating the IID assumption.

Ignoring these correlations leads to inconsistent results and suboptimal performance. When a classifier treats these points in a vacuum, it misses the opportunity to use the "consensus" of a group of related candidates to improve the final diagnosis.

Methods: Moving Beyond Independent Classification

The authors propose two distinct frameworks for Batch Classification:

  1. BatchProb (Probabilistic Approach): This model utilizes a Bayesian framework where raw classifier outputs are treated as noisy observations of an underlying ground truth. It incorporates a Gaussian prior with a covariance matrix defined by the spatial distance between candidates. If two candidates are physically close, the model expects their labels to be similar.
  2. BatchSVM (Mathematical Programming Approach): To address the computational overhead of matrix inversions in the probabilistic model, the authors developed BatchSVM. This approach produces a "pre-classifier" hyperplane. The final classification for any single point is determined by a weighted average of the pre-classifier scores of all related points within its batch.
Figure 2: Conceptual comparison of standard SVM vs BatchSVM. By modeling dependencies (b) within batches (a), BatchSVM (d) achieves a more robust decision boundary than standard SVM (c).

This "smoothing" effect ensures that spatially proximate candidates reach a consensus, effectively pulling individual predictions toward the group's collective evidence.

Experimental Results

The algorithms were evaluated on three real-world medical datasets provided by Siemens Medical Solutions:

  • Pulmonary Embolism (PE): In a dataset of 72 cases, standard SVM achieved 53% sensitivity at a rate of six false positives per patient. BatchSVM increased this to 80%, a significant 27% absolute improvement.
  • Colon Cancer: BatchSVM reached 84% sensitivity, while BatchProb achieved 89.6% at the same false-positive rate for identifying polyps.
  • Lung Cancer: Both batch methods outperformed standard classifiers in the clinically critical range of 2–6 false positives per image, which is the standard operating window for commercial CAD systems.

Conclusion

Batch classification provides a powerful alternative to independent classification in domains where data points are naturally grouped and correlated. By using spatial proximity as a proxy for correlation, BatchSVM and BatchProb offer the accuracy of joint classification with the efficiency required for real-time clinical applications. Future work may explore non-spatial correlations, such as institutional or demographic groupings, to further refine these models.

Summary updated

Abstract

Most classification methods assume that the samples are drawn independently and identically from an unknown data generating distribution, yet this assumption is violated in several real life problems. In order to relax this assumption, we consider the case where batches or groups of samples may have internal correlations, whereas the samples from different batches may be considered to be uncorrelated. Two algorithms are developed to classify all the samples in a batch jointly, one based on a probabilistic analysis and another based on a mathematical programming approach. Experiments on three real-life computer aided diagnosis (CAD) problems demonstrate that the proposed algorithms are significantly more accurate than a naive SVM which ignores the correlations among the samples.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
pulmonary embolism (PE) datasetBatchSVMsensitivity80%+27 vs baselineMedical Image Detection · split: test · operating-point=6 false positives per patient/image
Source quote
L421: However, BatchSVM achieves 80% with a remarkable improvement (27%). BatchProb also outperformsSVM with a 64% sensitivity. As seen from the figure, the two proposed methods are substantially more accurate than standard SVMs at any specificity level.
pulmonary embolism (PE) datasetBatchProbsensitivity64%+11 vs baselineMedical Image Detection · split: test · operating-point=6 false positives per patient/image
Source quote
L421: However, BatchSVM achieves 80% with a remarkable improvement (27%). BatchProb also outperformsSVM with a 64% sensitivity. As seen from the figure, the two proposed methods are substantially more accurate than standard SVMs at any specificity level.
Colon Cancer DataBatchSVMsensitivity84%+29.5 vs baselineMedical Image Detection · split: test · operating-point=1 false positive per patient/image
Source quote
L423: Figure 3b. However, BatchSVM improved SVM’s performance to 84% sensitivity for the same number of false positives. Note that BatchProb improved the sensitivity further, giving 89.6% for the same specifity. In one to ten false positives region which constitutes the region of interest in our applications, our proposed methods outperform standard SVM significantly.
Colon Cancer DataBatchProbsensitivity89.6%+35.1 vs baselineMedical Image Detection · split: test · operating-point=1 false positive per patient/image
Source quote
L423: Figure 3b. However, BatchSVM improved SVM’s performance to 84% sensitivity for the same number of false positives. Note that BatchProb improved the sensitivity further, giving 89.6% for the same specifity. In one to ten false positives region which constitutes the region of interest in our applications, our proposed methods outperform standard SVM significantly.
Reported baseline / comparator measurements (2)
BenchmarkMethodMetricScoreProtocol / Evidence
pulmonary embolism (PE) datasetstandard SVM baselinesensitivity53%Medical Image Detection · split: test · operating-point=6 false positives per patient/image
Source quote
L420: In Figure 3a, corresponding to the comparison of the ROC curves on the PE dataset, we observe that standard SVM can only achieve 53% sensitivity for six false positives.
Colon Cancer Datastandard SVM baselinesensitivity54.5%Medical Image Detection · split: test · operating-point=1 false positive per patient/image
Source quote
L422: Colon cancer data is a relatively easier data set than pulmonary embolism since standard SVM can achieve 54.5% sensitivity at one false positive level as illustrated in
BibTeX
@inproceedings{vural2006batch,
  author = {Volkan Vural and Glenn Fung and Balaji Krishnapuram and Jennifer G. Dy and R. Bharat Rao},
  title = {{Batch Classification with Applications in Computer Aided Diagnosis}},
  booktitle = {ECML},
  year = {2006},
  doi = {10.1007/11871842\_43},
}
Figure