NeurIPS 2026Coming to NeurIPS in Sydney?Explore papers, orals & directions

Colon Cancer Data

3 papers · 8 extracted observations · gene expression classification · Also indexed as colon-cancer-data

Showing 8 of 8 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & EvidenceReading list
2013ULasso (uncorrelated Lasso), 12 genes proposedAccuracy0.9355Gene Expression Classification · split: loocv · selected-genes=12Uncorrelated Lasso
Source quote
L326: 0.9355
2013Lasso, 6 genes baselineAccuracy0.8710Gene Expression Classification · split: loocv · selected-genes=6Uncorrelated Lasso
Source quote
L320: 0.8710
2013Elastic Net, 13 genes baselineAccuracy0.8710Gene Expression Classification · split: loocv · selected-genes=13Uncorrelated Lasso
Source quote
L323: 0.8710
2007PCARand index.654Gene Expression ClassificationClustering and feature selection using sparse principal component analysis
Source quote
L162: where p is the number of pairs of elements that are in the same cluster in both partitions X and Y (correct pairs), q is the number of pairs of elements in different clusters in both X and Y (error pairs), and {n \choose 2} is the total number of element pairs. The Rand index for varying levels of sparsity is plotted in Figure \ref{fig:rand}. The Rand index of standard PCA is .654 for colon cancer (.804 for lymphoma) as marked in Figure \ref{fig:rand}. The Rand index for the DSPCA factors of colon cancer using 13 genes is .669 and is the leftmost point above the PCA line. This shows that clusters derived using sparse factors can achieve equivalent performance to clusters derived from dense factors. However, DSPCA on the lymphoma data does not achieve a high Rand index with very sparse factors and it takes about 50 genes per factor to get good clusters.
2007DSPCARand index.669Gene Expression Classification · compressedClustering and feature selection using sparse principal component analysis
Source quote
L162: where p is the number of pairs of elements that are in the same cluster in both partitions X and Y (correct pairs), q is the number of pairs of elements in different clusters in both X and Y (error pairs), and {n \choose 2} is the total number of element pairs. The Rand index for varying levels of sparsity is plotted in Figure \ref{fig:rand}. The Rand index of standard PCA is .654 for colon cancer (.804 for lymphoma) as marked in Figure \ref{fig:rand}. The Rand index for the DSPCA factors of colon cancer using 13 genes is .669 and is the leftmost point above the PCA line. This shows that clusters derived using sparse factors can achieve equivalent performance to clusters derived from dense factors. However, DSPCA on the lymphoma data does not achieve a high Rand index with very sparse factors and it takes about 50 genes per factor to get good clusters.
2006BatchSVM proposedsensitivity84%Medical Image Detection · split: test · operating-point=1 false positive per patient/imageBatch Classification with Applications in Computer Aided Diagnosis
Source quote
L423: Figure 3b. However, BatchSVM improved SVM’s performance to 84% sensitivity for the same number of false positives. Note that BatchProb improved the sensitivity further, giving 89.6% for the same specifity. In one to ten false positives region which constitutes the region of interest in our applications, our proposed methods outperform standard SVM significantly.
2006BatchProb proposedsensitivity89.6%Medical Image Detection · split: test · operating-point=1 false positive per patient/imageBatch Classification with Applications in Computer Aided Diagnosis
Source quote
L423: Figure 3b. However, BatchSVM improved SVM’s performance to 84% sensitivity for the same number of false positives. Note that BatchProb improved the sensitivity further, giving 89.6% for the same specifity. In one to ten false positives region which constitutes the region of interest in our applications, our proposed methods outperform standard SVM significantly.
2006standard SVM baselinesensitivity54.5%Medical Image Detection · split: test · operating-point=1 false positive per patient/imageBatch Classification with Applications in Computer Aided Diagnosis
Source quote
L422: Colon cancer data is a relatively easier data set than pulmonary embolism since standard SVM can achieve 54.5% sensitivity at one false positive level as illustrated in