Generated emotional speech can often be recognized as angry or sad, yet listeners describe it as hollow. The literature calls this the emotional resonance gap, but it is usually measured with a single opinion score at one operating point. A single score cannot tell three different failures apart. The system may need a much larger acoustic push before listeners notice any emotion. Listeners' judgments may grow too slowly as the system's intensity setting rises. Or perceived feeling may flatten out below the level natural speech reaches, no matter how far the setting is pushed.
Speech-intelligibility research has a standard tool for exactly this kind of question: the psychometric function, an S-shaped curve relating a physical quantity to human judgments. Its fitted parameters separate the threshold, the slope, and the ceiling. We propose to fit such curves to human listening data along intensity continua for natural and synthetic emotional speech. Each continuum gets two curves, one for "which emotion and how strong" (recognition) and one for "does this sound genuinely felt" (resonance). The core bet is that the resonance gap appears as a lower ceiling on the resonance curve, while the recognition curve for the same synthetic speech matches natural speech. If that holds, it gives the gap a measurable, falsifiable definition. It would also explain why automatic emotion classifiers look fine while listeners do not.
Core Claim
Fitting a four-parameter logistic curve to human ratings along emotion-intensity continua lets us break the resonance gap into threshold, slope, and ceiling differences. We hypothesize a specific dissociation. Synthetic speech from intensity-controllable emotional voice conversion systems should match natural speech on the recognition curve but show a significantly lower ceiling on the resonance curve.
A secondary claim concerns automatic emotion recognizers. When their output is treated as another "listener," their curve should track human recognition and not human resonance. That would make the known mismatch between automatic metrics and human empathy judgments visible as a gap between curve parameters.
The practical payoff is a control knob that is calibrated honestly. Inverting the human curves gives intensity settings spaced in equal perceptual steps, and the ceiling tells designers where pushing the knob further stops helping.
Relation to Prior Work
The method comes from psychoacoustic calibration. Fraga et al. fit a three-parameter logistic from an objective quality score (PESQ) to recognition rates. They showed that the slope, threshold, and ceiling must differ across noise families, finding an almost 50% gap in recognition rate at the same PESQ of 2.0 between two groups of noise types. Yamada et al. fit separate logistics per word-familiarity tier, reaching $R^2$ between 0.88 and 0.91. Both results tell us to expect separate curves for each emotion and to use partial pooling rather than one universal curve.
Taal et al. constrain the design. They found that mappings calibrated on additive noise break down under non-linear processing. Emotional voice conversion is heavily non-linear, so we fit curves directly on each system's own continuum and never transfer a curve fitted on natural speech.
Our closest precedent is Pérez Ramón et al.. They fit a generalized logistic to accentedness ratings along acoustic continua and inverted it to synthesize tokens at equal perceptual steps, verified across four listener groups. We reuse the inversion, but we differ in two ways. Their target was a single segmental phonetic dimension. Ours is emotion, and we use the parameters themselves as the diagnostic, comparing curves across sources (natural against synthetic) and across judgment types (recognition against resonance).
The generation side supplies the systems under test. Emovox learns an intensity value in [0, 1] through relative-attribute ranking. EINet maps predicted valence, arousal, and dominance to intensity through a normalizing flow, a learned invertible transformation. Neither checks whether equal steps of its intensity value are equal steps for listeners, and neither asks where perception saturates. Nonparallel Emotional Speech Conversion is purely categorical and serves only as context.
On the resonance side, several papers motivate the work by documenting the gap:
- Zhen Chen describes the "auditory uncanny valley."
- Yin et al. show that deep music models fail to beat Markov baselines in stylistic success ($BF_{10}=0.18$) while all systems trail human music.
- Luo et al. and Welch et al. find that standard automatic metrics correlate poorly or negatively with perceived empathy.
These papers establish the gap but give no way to locate it. That missing measurement is what this proposal targets.
Research Program
Let $x \in [0,1]$ be a position along an intensity continuum. Let $y$ be a listener's rating rescaled to $[0,1]$. We fit
$$y(x) = d + \frac{c - d}{1 + e^{-a(x-b)}}$$
In this curve, $d$ is the floor (the rating given to neutral speech), $c$ is the ceiling (the highest rating reachable), $b$ is the threshold midpoint, and $a$ is the slope. The floor is needed because neutral speech is rarely rated at zero resonance or zero intensity.
Curves are fitted with a hierarchical Bayesian model. Parameters vary by listener, emotion, speaker, and source, and those levels are partially pooled, following the Bayesian psychometric practice in Du et al.. The quantity of interest is the posterior of the ceiling difference, $\Delta c = c_{\text{natural}} - c_{\text{synthetic}}$, computed separately for the recognition and resonance judgments.
We build three kinds of continua from the Emotional Speech Database (ESD), which contains 350 parallel utterances per speaker, 10 English and 10 Mandarin speakers, and five emotions.
The first is a natural-anchored continuum. For each speaker and each emotion (happy, angry, sad, surprise), we align the neutral recording with the emotional recording of the same sentence. We then interpolate pitch contour, energy, duration, and spectral envelope with a vocoder in seven steps. The endpoint is the real emotional recording.
The second and third are synthetic continua. We sweep the Emovox intensity value and the EINet intensity value over seven steps each, starting from the same neutral inputs.
The natural-anchored morph is itself processed audio. We therefore include resynthesized endpoints as a control, so that vocoder artifacts are not confused with the ceiling we are trying to measure.
Listeners rate each token twice, on separate screens. The recognition screen asks which emotion the token carries and how strongly. The resonance screen asks how genuinely felt the emotion sounds. Both use continuous sliders. Native listeners are recruited for each language. As an automatic "listener," the ESD emotion recognizer (reported accuracy 89% English, 92% Chinese in Zhou et al.) gets its own curves. These are fitted to its posterior probability for the target emotion across the same continua.
In the final stage, we invert the human recognition curve for each system to choose intensity settings at equal perceptual steps. This is the Pérez Ramón procedure applied to emotion. We validate those settings on fresh listeners. A short music extension could ask whether ratings of generated melodies saturate as structural repetition increases, using the controllable structure graphs of MELONS. We treat this as optional follow-up rather than a core deliverable.
Baselines
The do-nothing reference treats each system's raw intensity value as already perceptually linear. The predicted rating is just a linear rescaling of the value between the endpoint ratings. This reference also stands in for simple linear regression. The logistic model beats it if its held-out rating error is lower and if it detects curvature that the linear model misses. Held-out means new listeners and new sentences.
The strongest existing competitors are the learned intensity mappings inside EINet and Emovox. They are already built to make intensity controllable and perceptually meaningful.
EINet is the stronger system on the numbers in the file. On Mandarin ESD, EINet reports mel-cepstral distortion (a spectral distance from the target recording, lower is better) of 4.06, naturalness MOS of 4.38 ± 0.05, and speaker similarity of 75.18%. For perceived intensity, I found no reported result on Lacuna for EINet's intensity mapping measured as step equality, threshold, or ceiling. Emovox reports only that listeners distinguished weak, medium, and strong variants in best-worst scaling. No numerical result for it was found on Lacuna.
We run both systems exactly as released, on the same ESD sentences and speakers, with the same number of intensity steps and the same listener pool. Their intensity values serve as their own implied calibration. We beat them if, on new listeners, our inverted-curve settings produce perceptual step sizes with significantly lower variance than equally spaced native intensity values. We must also do this without lowering naturalness MOS below EINet's reported 4.38 by more than its confidence interval.
The ablation that isolates the key ingredient keeps everything identical but swaps the logistic for isotonic regression. Isotonic regression fits the best monotone step function, with no parametric form. A second ablation drops the floor parameter $d$. A third fits one curve per system instead of one per emotion. That last ablation tests whether the heterogeneity found by Fraga et al. carries over to emotions.
The automatic-listener baseline calibrates intensity against the emotion recognizer's curve instead of human ratings. It tests whether humans are needed at all.
Why not just…?
Why not just use isotonic regression or another flexible monotone fit? This is the most serious threat. For the inversion step, all that is required is a monotone function, and isotonic regression makes fewer assumptions. We will not argue around it. If isotonic regression matches the logistic on held-out step equality, we adopt it for the control knob. The diagnostic claim, however, needs asymptotes estimated with uncertainty and compared across sources. A step function fitted on seven points has no ceiling parameter, so it cannot extrapolate beyond the last sampled step. It also cannot pool information across listeners the way the hierarchical logistic does. The ablation measures both held-out error and the number of listener trials needed to reach a fixed error. The logistic earns its place only if it wins on data efficiency or if its ceiling estimates replicate across listener groups.
Why not just calibrate against an automatic emotion recognizer and skip listeners? The evidence that automatic metrics diverge from human affective judgments is strong. Luo et al. found a negative correlation between perplexity and empathy, and Zeng et al. found that poorly scored models were judged more comforting. However, that evidence comes from text dialogue rather than speech. Our automatic-listener curves test the question directly for speech. If the recognizer's parameters match human resonance curves, human listening becomes unnecessary for this purpose, and that would itself be a useful negative result.
Why not just collect resonance MOS at a few intensity levels? Three Likert points cannot separate a shifted threshold from a lowered ceiling. MELONS illustrates the limitation. Its single-point gap of 3.20 against 4.39 for human compositions says the gap exists but not where it lies. Our seven-step design costs roughly twice the listener time of a three-point study. It is the minimum that identifies four parameters, and we will state that cost openly.
Decisive Checks
The central hypothesis is supported if two conditions hold together. First, the 95% credible interval for $\Delta c$ on the resonance judgment excludes zero for at least one synthetic system. Second, the interval for $\Delta c$ on the recognition judgment includes zero. The comparison must hold after correcting against the resynthesized natural endpoints.
The hypothesis is falsified in either of two cases. If the synthetic and natural curves coincide on both judgments, the gap is not located along the intensity dimension at all. If the synthetic curves differ mainly in threshold $b$, the problem is insufficient acoustic push, which is an engineering issue rather than a ceiling on feeling.
For the automatic listener, the prediction is that its curve parameters lie closer to human recognition parameters than to human resonance parameters. We measure closeness as posterior distance in $(a, b, c)$.
For the control application, success means lower step-size variance than native intensity values on new listeners. We follow the multi-cohort validation logic of Pérez Ramón et al. and replicate the test separately with English and Mandarin listeners.
References
- Further investigations on the relationship between objective measures of speech quality and speech recognition rates in noisy environments
- Word intelligibility estimation of noise-reduced speech
- An evaluation of objective quality measures for speech intelligibility prediction
- Generating iso-accented stimuli for second language research: methodology and a dataset for Spanish-accented English
- Emotion Intensity and its Control for Emotional Voice Conversion
- Towards Realistic Emotional Voice Conversion using Controllable Emotional Intensity
- Nonparallel Emotional Speech Conversion
- Composing music under certain conditions based on neural network
- Deep learning's shallow gains: a comparative evaluation of algorithms for automatic music generation
- Assessing Empathy in Large Language Models with Real-World Physician-Patient Interactions
- Counseling-Style Reflection Generation Using Generative Pretrained Transformers with Augmented Context
- Measuring the Band Importance Function for Mandarin Chinese with a Bayesian Adaptive Procedure
- Emotional voice conversion: Theory, databases and ESD
- Melons: Generating Melody With Long-Term Structure Using Transformers And Structure Graph
- Affective Decoding for Empathetic Response Generation