A model deployed at a new hospital usually meets two problems together. The hospital has very few labeled patients, and its data look different from the training hospital's. Self-training is a natural fix: the model labels the hospital's many unlabeled patients and retrains on its own guesses, which are called pseudo-labels. Under class imbalance, though, self-training is known to feed on its own mistakes. Clinical data add a twist that the self-training literature has not studied. A patient arrives as several modalities, such as physiological time-series, structured diagnosis and treatment codes, and images, and a new hospital rarely shifts them all equally. A scanner change can wreck the image distribution while lab values barely move. Billing conventions can scramble codes while vitals stay comparable.
This note proposes using that unevenness on purpose. We first measure, at the target hospital, which modality has stayed reliable for each class. That modality then labels the unlabeled patients, and the pseudo-labels train the modality that has shifted. No model ever trains on its own guesses. Our claim is that this directional, cross-modal pseudo-labeling breaks the confirmation-bias loop for a structural reason. When two modalities fail for unrelated reasons, the teacher's errors are close to independent of the student's errors, so the student cannot reinforce what it already believes. A fused model labeling itself loses this property: it mostly labels by its dominant modality.
Why this gap is real
Three findings in the literature motivate the proposal. Distribution Aligning Refinery of Pseudo-label (DARP) refines pseudo-labels so their class totals match an estimated prior. Its motivating finding is that standard self-training turns an imbalance ratio of 150 into an effective pseudo-label ratio above 1,000, with minority classes ending up worse than supervised training on the labeled set alone. Autoregressive EHR Foundation Models with Multimodal Inputs fuses electronic health record (EHR) codes, ECG, chest radiographs and notes on MIMIC-IV. It finds that dense codes crowd out sparse modalities: adding radiographs lowered zero-shot mortality AUROC from 0.8651 to 0.8624, while adding notes raised it to 0.8751. Combining the two findings gives a prediction. A fused model that pseudo-labels itself will label mainly by codes, so self-training will lock in code-driven errors and keep starving the image pathway. Can We Trust Deep Learning Based Diagnosis? measures cross-site collapse in chest radiographs, with AUC falling from 0.83 internally to 0.68 on CheXpert. It also shows that labels produced by automated report-reading tools carry 10–30% error and can create apparent robustness.
That third finding also limits the design. Our method relies on modalities failing independently. Any modality that shares a source with the labels, as report text does with labels mined from reports, breaks that assumption. We treat that case as a planned negative control rather than ignoring it.
The closest existing work avoids the multimodal question in one of two ways. BoostMIS combines adaptive confidence thresholds with active learning on single-modality medical images, and it does not test cross-site shift. Cluster-Guided Semi-Supervised Domain Adaptation concludes that pseudo-labels are too biased under imbalanced cross-hospital transfer. It drops them in favor of constrained clustering, again on images only. DC-SSL and CoLA correct class-distribution mismatch for a single input stream. DC-SSL uses a moving-average teacher's class distribution, and CoLA calibrates logit penalties using the effective rank of class features. All of these assume one input stream, so a single model is both labeler and learner. The proposal differs in one respect: across modalities, labeler and learner are separated, and the routing is decided by measured shift rather than by confidence.
Core Claim
Suppose the target hospital has a small labeled set (16 to 128 patients) and a large unlabeled pool. Let each modality $m$ have its own prediction head $f_m$, trained at the source hospital. For each class $c$, the method picks a teacher modality
$$t(c) = \arg\max_m \hat{R}_m(c),$$
where $\hat{R}_m(c)$ is the estimated recall-weighted precision of head $f_m$ on class $c$ at the target hospital. Teacher predictions are then used only to supervise the heads of the other modalities.
The class quotas for pseudo-labels come from a target class prior $\hat{\pi}$. We obtain it by correcting the teacher's raw prediction frequencies with its confusion matrix $C_t$, estimated on the small labeled set:
$$\hat{\pi} = C_t^{-1}\,\bar{q}_t,$$
where $\bar{q}_t$ is the teacher's average predicted class distribution over the unlabeled pool. This answers the open problem DARP and DC-SSL leave behind: their alignment needs a target prior, and an error in that prior creates a second bias. Here the prior comes from the modality that shifted least, not from the biased model being corrected.
The reliability estimate $\hat{R}_m(c)$ uses two sources. The first is the tiny labeled set. The second is agreement rates among three or more modality heads on unlabeled patients. If the heads' errors are roughly independent given the true class, pairwise agreement rates determine each head's error rate without labels. The labeled set then checks whether that independence assumption holds.
The falsifiable prediction has three parts. First, measured on held-out target labels, cross-modal pseudo-labels should be far less correlated with the student's existing errors than self-generated ones. Second, the pseudo-label imbalance ratio should stay near the true target ratio instead of inflating. Third, and most importantly, the student modality should end up better than its teacher on classes where it carries complementary information.
Research Program
The first phase is measurement and builds no new method. On source-trained models, we quantify how pseudo-label errors from a fused self-teacher correlate with each modality head's errors at the target hospital. We also measure how much the effective pseudo-label imbalance ratio grows over self-training rounds. This tests Gap 2 directly: does self-training in a fused clinical model amplify the dominant modality's bias? If fused self-training turns out not to amplify, the motivation weakens, and we will report that.
The second phase builds the directional method on top of a standard weak/strong augmentation self-training loop. Four pieces are added in turn: per-modality heads with modality dropout, the per-class reliability estimate, prior-corrected class quotas, and a final fused head retrained on the debiased modality encoders. Following Adapt the Data, Not the Model, which adapts inputs because certified clinical models often have locked weights, we also run a locked variant. In it, only an input adapter for the shifted modality is trained, and the downstream predictor stays frozen.
The third phase is the controlled stress test. We vary how severe the shift is in each modality, and how imbalanced the classes are, independently. The goal is to map where directional routing helps, where it ties simpler methods, and where it fails. Failure is expected, for example, when every modality shifts heavily, or when two modalities share a label source.
Testbeds
The real cross-site arm uses the YAIB benchmark, with MIMIC-IV as the source and eICU and HiRID as targets. Here the two modalities are irregular physiological time-series and structured diagnosis and treatment records. The tasks are mortality, acute kidney injury and sepsis, which have imbalanced outcomes, and the outcome labels are not derived from text.
The imaging arm uses the MIMIC-IV ecosystem (MIMIC-IV, MIMIC-CXR-JPG, MIMIC-IV-Note) in MEDS format, as in the autoregressive EHR study. This ecosystem is a single institution, so imaging shift there must be induced. We use acquisition-era splits plus controlled image-intensity and resolution degradations calibrated to match the cross-site degradation of a radiograph-only model trained on MIMIC-CXR and tested on CheXpert and ChestX-ray14, which are image-only external sets. The imaging arm is therefore partly synthetic. We say so plainly, and conclusions about real scanner shift rest on the radiograph-only external check.
The labeler-effect negative control runs inside the imaging arm. Notes teach the image head for findings labeled by mining radiology reports, and mortality serves as the comparison label. Because report-derived labels share errors with the notes, we predict directional routing loses its advantage for the report-mined findings but not for mortality.
Baselines
The naive reference points are two models with no use of unlabeled data. The first is the source model applied unchanged at the target hospital. The second is that model fine-tuned, or linearly probed when weights are locked, on the same small labeled target set. This tells us whether any unlabeled-data method earns its complexity.
The strongest cross-site competitor on the time-series arm is INPUTADAPTER from Adapt the Data, Not the Model. It trains an input transformer through a frozen predictor and reports a +14.1 point AUCPR improvement for acute kidney injury on eICU. The file gives no absolute AUCPR, so the comparison point must be reproduced. INPUTADAPTER needs target labels, so we run it on exactly our labeled budget with the same backbone and the same hyperparameter search budget. It is the strongest competitor because it is the best reported method for this exact source-target pair under locked weights.
The strongest pseudo-label debiasing competitor is DARP prior-aligned pseudo-labeling applied to the fused model. It reports relative error reductions of 53.1% over FixMatch on CIFAR-10 under mismatch. No reported result was found on Lacuna for DARP on multimodal clinical data. We give it the same augmentations and rounds, and the same small labeled set to estimate its prior. We also run the class-balanced dynamic thresholds of BoostMIS, without its active-learning component so the label budgets match. BoostMIS reports +4.73% over FixMatch on MESCC two-grade, but no number on our tasks. FixMatch on the fused model is included as the standard reference. Cluster-Guided Semi-Supervised Domain Adaptation represents the no-pseudo-label position. Its paper reports no numeric values in the file, so we reimplement its constrained k-means guidance loss on the fused representation.
Three ablations isolate the key ingredient. The first keeps our quotas and prior but lets the fused model label itself, which tests whether cross-modal routing matters. The second uses symmetric co-training, where every modality labels every other with no reliability-based routing, which tests whether direction matters. The third uses raw teacher frequencies instead of the confusion-corrected prior. The method counts as beating the field only if all three hold on eICU and HiRID across five seeds. Minority-class recall and AUCPR must exceed the best of DARP-fused and INPUTADAPTER. The improvement must exceed the seed spread. And the pseudo-label imbalance ratio must stay within a factor of two of the true target ratio while fused self-training inflates it.
Why not just…?
Why not just fine-tune or probe on the small labeled target set and skip unlabeled data? This is the most serious threat. Record2Vec reports that a portable representation fine-tuned on 16 target samples approaches a model trained from scratch on more than 36,000 local samples. If that held for minority outcomes, self-training would add little. Our experiments sweep the labeled budget from 16 to 512 patients. If the directional method's advantage over the probe disappears by about 64 labels, we will report the method as useful only below that budget. We also report a Record2Vec-style frozen-embedding probe as an extra reference, with the caveat that the paper itself notes its summarization step adds runtime latency.
Why not just drop the shifted modality and predict with the stable one? If the stable modality alone matched the full method, cross-modal teaching would be pointless. The deciding measurement is whether the final fused model beats the stable-modality teacher alone, on held-out target labels, for the classes where the student modality carries extra signal. The note-fusion gain in the autoregressive EHR study, from 0.8651 to 0.8751 AUROC, suggests such extra signal exists. A failure to beat the teacher would falsify the core claim.
Why not just apply DARP or adaptive thresholds to the fused model? These methods fix the class totals of pseudo-labels but not their source. A fused model can produce correctly balanced pseudo-labels that are still driven by its dominant modality, and its prior estimate inherits the shift. The same-quota self-labeling ablation addresses this directly. If it matches the directional method, routing adds nothing beyond prior alignment, and we will say so.
Why not just avoid pseudo-labels with cluster guidance? Clustering on a fused representation inherits the same dominance by codes, because the clusters are formed by the representation that codes dominate. Cluster guidance is run as a full baseline. Its comparison with the directional method across the shift-severity grid will show which approach holds up as imbalance grows.
Decisive Checks
Three results would settle the proposal. First, on eICU and HiRID, the directional method must beat DARP-fused, INPUTADAPTER and the small-set probe on minority AUCPR at labeled budgets of 64 or fewer. Second, error correlation between teacher and student must be measurably lower under cross-modal routing than under self-labeling, with pseudo-label imbalance staying near the true ratio. Third, the labeler-effect control must show the predicted loss of advantage when notes teach images on report-mined labels. If the second check fails, the mechanism is wrong even if accuracy improves. If the third check fails, the reliability estimate is not detecting shared label sources, and it needs to be redesigned before anyone trusts it at a real hospital.
References
- Distribution Aligning Refinery of Pseudo-label for Imbalanced Semi-supervised Learning
- Autoregressive EHR Foundation Models with Multimodal Inputs
- Can We Trust Deep Learning Based Diagnosis? The Impact of Domain Shift in Chest Radiograph Classification
- BoostMIS: Boosting Medical Image Semi-supervised Learning with Adaptive Pseudo Labeling and Informative Active Annotation
- Cluster-Guided Semi-Supervised Domain Adaptation for Imbalanced Medical Image Classification
- DC-SSL: Addressing Mismatched Class Distribution in Semi-supervised Learning
- CoLA: Co-Calibrated Logit Adjustment for Long-Tailed Semi-Supervised Learning
- Adapt the Data, Not the Model: Input-Space Adaptation for Frozen Time-Series Predictors
- Can we generate portable representations for clinical time series data using LLMs?