Iodine-Removal Shapley Values for Auditing Small-Cohort CT Arthrography Models

CT arthrography works because injected iodine contrast forces the joint open and fills cracks in cartilage and labrum, which makes those cracks visible. Any deep network trained to read these scans should therefore rely on where the contrast went. On the small cohorts this invasive exam produces, though, a network could just as easily learn something else: how much the joint was distended, which scanner was used, or the bone shape of a typical patient at one site. Standard explanation tools cannot reliably tell these cases apart. Gradient heatmaps are coarse. Perturbation methods, which estimate a region's importance by deleting it and watching the prediction change, delete it by zeroing or blurring voxels. That produces impossible images, and the model's answers on such images mean little.

We propose that dual-energy CT arthrography already contains a physically valid way to "remove" a feature. Its virtual non-contrast reconstruction, an image computed from the two X-ray energies with the iodine signal digitally subtracted, shows what each region would look like if contrast had not entered it. We therefore treat a small set of anatomical compartments as players in a Shapley attribution, a game-theoretic method that splits a prediction among input parts by averaging each part's marginal effect over all combinations of the others. A compartment is "absent" when it is shown in its iodine-free form. With about ten compartments, exact Shapley values are cheap to compute. The resulting attributions answer the clinically meaningful question directly: how much of this prediction comes from contrast entering the defect? The main use is not prettier heatmaps. In cohorts of 25 to 100 patients, we want these attributions to identify which trained model has learned the real mechanism and which has learned a shortcut, and to do so better than validation accuracy can.

Core Claim

We claim three things. First, region-level Shapley values that use iodine removal as the absence operator are more faithful than gradient saliency or voxel-masking Shapley on contrast-distended joints. Faithfulness here means they recover a known, planted dependence. Second, the share of attribution falling on contrast within the lesion compartment, which we call the mechanism share, predicts how a small-cohort model will perform at an unseen site or scanner. Third, it does this better than internal cross-validated area under the ROC curve, so it can be used to choose among models when labeled data are too few to trust validation scores alone.

Formally, let $x$ be the acquired arthrogram and $\tilde{x}$ its virtual non-contrast reconstruction. Let $R_1,\dots,R_K$ be anatomical compartments, for example anterior labrum, posterior labrum, glenoid surface cartilage, humeral head surface, axillary recess, subscapular recess, biceps sheath, and extra-articular background. The value of a coalition $S \subseteq \{1,\dots,K\}$ is

$$v(S) = f\big(x \odot M_S + \tilde{x} \odot (1 - M_S)\big),$$

where $f$ is the trained classifier's logit, $M_S$ is a soft mask equal to 1 on compartments in $S$, $\odot$ is voxelwise multiplication, and the mask edges are feathered over about one millimeter to avoid seams. The standard Shapley value of each compartment then follows from $v$. With $K \le 12$, exact computation needs at most 4,096 forward passes per scan. That sidesteps the exponential cost the research file flags for voxel-level Shapley values.

Relation to Prior Work

The CT arthrography literature motivates the problem but supplies no method for it. Braun et al. show that ankle CT arthrography finds full-thickness cartilage defects that MRI misses. Sutter shows it quantifies glenoid bone loss that MRI underestimates. Dietrich et al. reach a consensus on its value for wrist ligament tears. All three rely on human readers, and none trains a model. The dual-energy shoulder studies, virtual non-contrast for loose bodies and iodine removal for glenoid reformats, supply our key ingredient. They show that iodine can be removed cleanly enough for diagnostic reading. We reuse that reconstruction for a different purpose: as the counterfactual "absent" input of an attribution game.

On attribution, Holzinger et al. review the axioms that make Shapley values unique. They also name the out-of-manifold problem, in which masking produces unrealistic inputs, as an open flaw. We address that flaw in one modality where physics provides a realistic replacement, without claiming a general fix. The closest existing work is EGxFSL/xGAL. It adds a loss that pulls Grad-CAM heatmaps toward expert regions during few-shot training and uses explanation misalignment to choose which samples to label. Our proposal differs in three ways. We do not train on explanations. We use attribution as a post-hoc measurement for selecting models and auditing them. Our attribution uses a physically grounded removal operator rather than gradients. It is also volumetric and defined over anatomical compartments, not 2D pixels. We deliberately avoid an alignment loss. EGxFSL itself reports that its alignment weight had to be tuned (α = 0.10) and that guidance quality dropped with coarse masks, and thin-cartilage lesions would make that tension worse.

On small samples, Tartaglione et al. show that chest X-ray models trained on a few hundred images group cases by acquisition source and fail at external sites. Their remedy, cropping to anatomy, removes shortcuts outside the region of interest. It cannot address shortcuts inside the joint, such as how much the capsule was distended. That finding motivates our central test: whether attributions can predict external failure. Bria et al. use SHAP only on low-dimensional sensor features, and Liang et al. show that in-domain pre-training beats ImageNet pre-training at very low label fractions. We use their conclusion to justify how we initialize the backbones, not as a competitor.

Research Program

We will assemble a retrospective dual-energy shoulder CT arthrography cohort. Labels for anterior or posterior labral tear and for intra-articular loose body will come from operative reports where available and from two-reader consensus otherwise. Acquired images and virtual non-contrast images will be reconstructed together. The cohort should come from at least two scanners or sites so that one can be held out as an external test. The research file contains no public CT arthrography dataset, so this cohort is a real dependency and the main practical risk.

Compartment masks will be produced semi-automatically. A bone threshold and the iodine map will propose joint-space recesses, and a reader will correct them. We expect this to take a few minutes per scan, since compartments are coarse.

From each training set we will train many small 3D classifiers. Training sets will be subsampled to N = 25, 50, and 100. The classifiers will span shallow 3D convolutional networks, an in-domain pre-trained backbone, different augmentations, and different random seeds. Spanning these choices deliberately produces models of varying quality.

For every model we will compute five attributions: compartment Shapley values with iodine removal, the same Shapley values with mean-intensity removal, the same with Gaussian-blur removal, 3D Grad-CAM pooled per compartment, and Integrated Gradients pooled per compartment. Integrated Gradients is run in two versions, one using a black reference image and one using the virtual non-contrast image as reference. The mechanism share of each attribution is the absolute attribution on the lesion compartment divided by total absolute attribution.

We will also measure how far each removal operator moves inputs off the data. We fit a density model to the classifier's penultimate-layer features on real scans and report the likelihood of the perturbed scans under that model. If iodine removal does not keep inputs closer to the real data than masking does, the method's premise fails, and we would report that.

Baselines

The naive reference point is model selection by internal cross-validated area under the ROC curve, using no attribution at all. This is what a group with 50 cases would actually do. Every attribution-based selection rule must beat it at predicting external-site area under the curve, or the attributions have no practical value.

The strongest existing competitor is Grad-CAM-based expert alignment in the style of EGxFSL. In our setting it becomes the overlap between pooled 3D Grad-CAM and the lesion compartment, used as a selection score. It is the strongest competitor because it is the only method in the file that connects attribution to small-sample medical imaging. EGxFSL reports 92.05% few-shot accuracy on BraTS against 89.21% for its unguided baseline. That is an accuracy number on a different task and modality. We found no reported result on Lacuna for attribution faithfulness or for attribution-based model selection on CT arthrography or any musculoskeletal CT. Our comparison therefore has to be internal.

The cheaper and most direct competitor is Integrated Gradients with the virtual non-contrast image as its reference. It uses the same physical counterfactual and costs one path integral instead of thousands of forward passes.

The ablation that isolates our key ingredient holds the players, models, and number of evaluations fixed and changes only the removal operator: iodine removal versus mean intensity versus blur.

For fairness, all attribution methods run on identical trained checkpoints, identical compartment masks, and identical held-out scans. Each method gets the same compute budget per scan, matched by subsampling coalitions for the masking variants if needed. Selection rules have no tunable parameters beyond the definition of mechanism share. Beating a baseline means two things. First, a higher rank correlation between the selection score and external-site area under the curve, with a bootstrap confidence interval over models that excludes zero difference. Second, higher top-1 recovery of the planted shortcut described below.

Why not just…?

Why not just use Grad-CAM, as EGxFSL does? Grad-CAM in a 3D network inherits the resolution of the last feature map, which is typically several millimeters per cell. Ankle cartilage, as Braun et al. note, is 0.4 to 2.1 mm thick, and labral clefts are similarly fine. Grad-CAM also lacks the efficiency and null-player guarantees reviewed by Holzinger et al., so a compartment the model ignores can still receive heat. Pooling Grad-CAM per compartment is a fair fight, because it removes the resolution handicap at our granularity. The planted-shortcut test decides whether coarse gradients still misplace credit once resolution is no longer the issue.

Why not just use Integrated Gradients with the virtual non-contrast image as the reference? This is the real threat, since it captures much of our idea at a fraction of the cost. Its path runs through blends of the full scan with its iodine-free version, so every intermediate image changes all compartments at once. It therefore measures each compartment's contribution only along one particular route, not averaged over which other compartments contain contrast. When the decision depends on an interaction, for example contrast in the labral cleft counting only if the recess is also distended, the two methods should diverge. We will report agreement between them. If Integrated Gradients with this reference matches compartment Shapley on shortcut recovery and on predicting external performance, we will recommend it and present the Shapley version as its validation, not as the method.

Why not just crop to the joint, as Tartaglione et al. did, and skip attribution? Cropping removes shortcuts outside the joint, such as positioning pads and scanner edges. The shortcuts specific to arthrography sit inside the joint: how much contrast was injected and how large the recess appears. Cropping cannot see them. All our models will be trained on joint crops anyway, so any shortcut the attributions detect is one that cropping missed.

Why not just let radiologists read the virtual non-contrast and iodine images and forget models? For diagnosis, that is today's practice, and we do not dispute it. The proposal is aimed at the moment someone deploys a model trained on few cases. At that point the open question is whether that model relies on the mechanism readers rely on, and human reading of images cannot answer it.

Proposed Experiments

The first decisive check is a planted shortcut, which gives non-circular ground truth for faithfulness. In half the training runs we create a spurious correlation between label and distension. For positive cases we computationally remove iodine from a randomly chosen fraction of a non-lesion recess. For negative cases we leave it untouched. In other runs we add a scanner-specific noise texture to the background of one class. Models are trained on these altered sets and tested on clean scans, where they fail in a known way. A faithful attribution should rank the planted compartment first. We report top-1 and top-3 recovery for every method and every N. Because the planted change is itself an iodine removal, it might seem to favor our operator. To control for this, the texture shortcut is not iodine-based, and the claim holds only if our method wins on both kinds of shortcut.

The second check is external prediction. Across all naturally trained models, we correlate each selection score with area under the curve on the held-out site, separately for N = 25, 50, and 100. The prediction is that mechanism share beats internal cross-validation most clearly at N = 25, where cross-validation estimates are noisiest, and that the gap narrows as N grows. If mechanism share fails to beat cross-validation at every N, the central practical claim is false.

The third check concerns clinical plausibility. On the held-out set, two musculoskeletal radiologists, without seeing model outputs, mark which compartment's contrast pattern drives their own call. We report how often each method's top compartment matches theirs, using Cohen's kappa for consistency with how the arthrography literature reports reader agreement. The off-manifold density measurement described above is reported alongside, so readers can see whether a faithfulness gain coincides with perturbed inputs staying closer to the real data. Shoulder is the primary joint. If a dual-energy ankle subset is available, we will repeat the external-prediction test on full-thickness talar defects, where the gap between thin cartilage and coarse saliency should be largest.