Forecasting Next-Cycle Kidney Dose in PSMA Radioligand Therapy as the Tumor Sink Shrinks

Radioligand therapy for metastatic prostate cancer works by injecting a radioactive drug that seeks out a protein called PSMA on tumor cells. The same molecule, labeled with an imaging isotope instead of a killing one, is scanned first to show where the drug will go. That pairing is the point of theranostics: the diagnostic and the therapeutic share one targeting molecule. Healthy organs that also carry PSMA, above all the kidneys and salivary glands, absorb radiation too, and treatment runs over several cycles. The tumor itself competes with these organs for a fixed amount of injected drug. A large tumor "soaks up" drug and shields them, and as the tumor shrinks under therapy, more drug reaches the kidneys. Tumor Sink Effect in 68Ga-PSMA-11 PET: Myth or Reality? reports an average rebound of 74% in kidney uptake in a 20-patient longitudinal sub-cohort. This creates a clear danger. The patients who respond best are the ones whose kidney dose climbs fastest, yet the usual assumption is that next cycle's organ dose per unit of injected activity matches last cycle's. That assumption fails exactly in those responders.

This note proposes a small, testable model for the next cycle's kidney absorbed dose. It anchors on the previous cycle's measured dose. It then corrects that value for two things: how much the tumor sink has shrunk, estimated from interim imaging or, when no scan exists, from the blood PSA trajectory, and how renal function has changed according to routine labs. The contribution is a claim about where the error lives. We claim that most of the correctable cycle-to-cycle error in organ dose comes from sink shrinkage and renal drift, both of which sit in clinical and imaging records that current dosimetry models ignore. We test this with nested models in which each ingredient can be switched off.

Core Claim

Current deep dosimetry models map a pre-therapy PET scan to a dose map and see nothing else. The one clinical study of the sink effect measures it but does not predict with it. We claim that a mechanistic anchor-and-correct model will predict cycle-$c$ kidney mean dose per gigabecquerel substantially better than carry-forward of the cycle-$(c-1)$ measurement, and better than image-only prediction, with the gain concentrated in patients whose tumor burden falls between cycles. The core relation is

$$ \hat D_{K,c} = D_{K,c-1}\cdot\frac{1+\lambda V_{T,c-1}}{1+\lambda V_{T,c}}\cdot\exp\!\big(\beta^\top (x_c - x_{c-1})\big), $$

where $D_{K,c-1}$ is the measured kidney dose per GBq at the previous cycle and $V_{T,c}$ is the PSMA-positive tumor volume at cycle $c$. The fraction is the redistribution of a fixed ligand mass when tumor binding capacity, scaled by $\lambda$, competes with organ uptake. The vector $x_c$ holds renal and systemic covariates (eGFR, creatinine, hemoglobin, body mass), and $\beta$ holds their effects. Carry-forward is the special case $\lambda=0,\ \beta=0$, so every ingredient can be ablated by fixing a parameter.

The multimodal-integration literature enters in two ways. It supplies the lens: When Does Multimodal Learning Help in Healthcare? A Benchmark on EHR and Chest X-Ray Fusion found fusion helps only for "modality-distributed" endpoints. We pre-register the hypothesis that kidney dose change is such an endpoint and that absolute dose is not. It also supplies a constraint: interim PET is often missing, and naive fusion collapses under missingness. The model therefore must degrade gracefully to a PSA-only estimate of $V_{T,c}$.

Relation to Prior Work

Three papers motivate the gap. Pre-therapy PET-based voxel-wise dosimetry prediction by characterizing intra-organ heterogeneity in PSMA-directed radiopharmaceutical theranostics trains 3D RPT DoseGAN, a 3D generative adversarial network (an image generator trained against a discriminator), to turn pre-therapy PET/CT into cumulative dose maps. It shows PET–dose correlation is only moderate (kidney $r=0.77$, liver $r=0.50$). That model is strictly image-to-image, predicts each cycle independently, and was trained on 23 patients. We keep its voxel-level idea as an optional residual layer but make the organ-level prediction longitudinal and clinically informed. The tumor-sink study establishes the cross-sectional relation between tumor volume and organ uptake across 406 patients but builds no predictor. We turn its cross-sectional curve into a prior for $\lambda$ and test whether it transfers to within-patient change. PSMA PET total tumor volume predicts outcome of patients with advanced prostate cancer receiving [177Lu]Lu-PSMA-617 radioligand therapy in a bicentric analysis fuses baseline PET volume metrics with PSA and LDH for survival using Cox regression, a standard survival model. It is static and targets survival, whereas we target a toxicity-relevant dose and let the inputs change across cycles.

Two papers supply methods. From FDG to PSMA: A Hitchhiker's Guide to Multitracer, Multicenter Lesion Segmentation in PET/CT Imaging gives the segmenter we reuse to extract $V_{T,c}$ automatically. Comprehensive Evaluation of Quantitative Measurements from Automated Deep Segmentations of PSMA PET/CT Images warns that high overlap scores do not guarantee accurate volumes (its "Dice paradox"), so we validate volume agreement directly rather than overlap.

Two papers constrain the design. The chest X-ray fusion benchmark warns against unstructured deep fusion under missing data. Recommendations for Standardizing Nuclear Medicine Terminology and Data in the Era of Theranostics and Artificial Intelligence documents that different groups computing ¹⁷⁷Lu dose from identical images disagree substantially. That forces us to fix one dosimetry pipeline across all sites and to report measurement noise as a floor on achievable error.

Research Program

We would assemble a retrospective multi-center cohort of patients treated with [¹⁷⁷Lu]Lu-PSMA who had post-therapy quantitative SPECT/CT dosimetry after at least two cycles. We target several hundred cycle transitions across at least three centers, possibly drawing on the SNMMI registry RaPTR named in the standardization paper. All SPECT data are re-processed through a single dosimetry pipeline. Organ contours come from a fixed segmenter.

Tumor volume is measured in three ways. The first is baseline PSMA PET segmented by the autoPET-style model. The second is interim PET where it exists. The third, when no interim scan exists, is a latent estimate driven by the PSA time series and the post-therapy SPECT tumor signal. This last route is the missing-modality path. We model it explicitly as a measurement model rather than imputing blindly.

We fit $\lambda$ and $\beta$ hierarchically, with center as a random effect. The prior on $\lambda$ comes from fitting the competing-sink form to cross-sectional pre-therapy PET organ uptake versus tumor volume. That makes the cross-sectional-to-longitudinal transfer an explicit, testable assumption. As a secondary layer, a small 3D network predicts the voxel-wise ratio of cycle-$c$ to cycle-$(c-1)$ kidney dose, so that DVH-level shape changes are captured. It is initialized from the DoseGAN recipe and its organ mean is constrained to the mechanistic prediction.

Baselines

The naive reference is carry-forward: predict cycle-$c$ kidney dose per GBq as the measured cycle-$(c-1)$ value. This is roughly what fixed-activity or fixed-cumulative-budget practice implicitly assumes. It is the most important competitor because it already contains the patient's individual kidney kinetics. No reported result was found on Lacuna for carry-forward accuracy of multi-cycle ¹⁷⁷Lu-PSMA kidney dose, so we measure it ourselves on the same cycle transitions.

The simplest image-based reference is direct projection, which linearly scales pre-therapy PET uptake to dose. The strongest existing method is 3D RPT DoseGAN. On its cohort, it reports voxel-wise NRMSE of 0.79% versus 1.11% for direct projection, and a kidney DVH $R^2$ of 0.92 (Pre-therapy PET-based voxel-wise dosimetry prediction). We retrain it on our cohort with the same patient-level cross-validation splits and the same hyperparameter search budget as our model, and feed it the most recent PET before each cycle. It only sees a new PET at cycle $c$ when one exists; otherwise it reuses baseline PET, which mirrors clinical reality. For fairness, we also report it on the interim-PET subset only.

A generic fusion baseline concatenates DoseGAN organ features, labs, PSA history, and the prior-cycle dose into a gradient-boosted regressor with identical inputs to ours. It tests whether our mechanistic structure matters or merely the inputs.

The ablations are nested. We fix $\lambda=0$ to remove the sink, fix $\beta=0$ to remove the labs, replace interim-PET volume with the PSA-only estimate, and drop the prior-cycle anchor, reverting to absolute prediction. Beating the baselines means lower median absolute percentage error on cycle-$c$ kidney dose per GBq than carry-forward, with the bootstrap confidence interval excluding zero. In the pre-defined responder stratum (patients whose tumor volume falls by at least a pre-registered fraction between cycles), it also means removing carry-forward's systematic underestimation, measured as mean signed error.

Why not just…?

Why not just carry the previous cycle's measured dose forward? This is the real threat, and in non-responders it may be close to optimal, since little changes. The sink study's +74% average kidney rebound in shrinking tumors says carry-forward should be biased low exactly when the stakes rise. That figure comes from PET uptake in 20 patients, not measured dose, so we treat it as a hypothesis. The nested design settles the question: if the fitted $\lambda$ is near zero and the ablation with $\lambda=0$ matches the full model in responders, the sink correction is not worth deploying, and we will report that.

Why not just add eGFR and creatinine as extra input channels to DoseGAN? End-to-end deep fusion on a few hundred transitions invites overfitting. The chest X-ray fusion benchmark also shows naive fusion tends to lean on whichever stream is easiest and to fall below unimodal baselines under missingness. The generic fusion baseline and a DoseGAN-plus-labs variant, trained under the same budget, test this directly. If either matches our model, the mechanism is unnecessary and we would adopt the simpler model.

Why not just apply a population regression of kidney uptake on tumor volume from pre-therapy PET? This is the cross-sectional sink correction, and it is what our prior on $\lambda$ uses. It ignores the individual patient's kinetics, which the prior-cycle anchor supplies, and assumes that between-patient and within-patient slopes agree. Comparing the prior-only $\lambda$ with the longitudinally fitted $\lambda$ tells us whether that assumption holds.

Why not just perform SPECT dosimetry after every cycle and skip prediction? Many centers already do. But the measurement arrives after injection, while the activity decision must be made before it. Prediction is what turns measurement into adaptive dosing.

Proposed Experiments and Decisive Checks

The first experiment validates tumor-volume extraction. Using the LesionTracer-style segmenter, which won the model-centric category of autoPET III with Dice 68.40 (From FDG to PSMA), we check agreement of automated PSMA total tumor volume with expert volumes on our cohort. Following the Dice-paradox paper, the pre-registered criterion is concordance on volume within a 20% margin, not overlap.

The second experiment is the main comparison. We run patient-level, leave-one-center-out evaluation of all baselines and ablations on cycle-$c$ kidney mean dose per GBq, reporting median absolute percentage error, signed bias in the responder and non-responder strata, and kidney DVH $R^2$ for the voxel layer. The error of inter-pipeline re-dosimetry on a held-out subset serves as the noise floor.

The third experiment is decisive. Our claim survives if all three of the following hold. The full model beats carry-forward overall. Setting $\lambda=0$ reinstates carry-forward's underestimation in responders. The PSA-only volume path keeps most of the gain when interim PET is withheld.

A secondary check applies a pre-registered center-specific cumulative kidney dose limit. Using prospective-style simulation over each patient's cycle sequence, we measure how often each model correctly predicts that the next cycle would cross that limit. This is the clinically actionable decision.

We also test the modality-distributed hypothesis directly. Labs and sink should help the change in dose but add little to absolute single-cycle dose once PET is present. If they help both or neither, the CareBench framing does not transfer and we report it as such.