ReXVal · Radiology Report Evaluation
10 papers · 27 extracted observations · radiology report evaluation · Markdown · CSV · JSON API
Tasks on ReXValAll tasks (10)Radiology Report Evaluation (6)Medical Report Evaluation (2)Report Evaluation (1)Report Generation (1)
TaskRadiology Report Evaluation (12)Medical Report Evaluation (6)Report Evaluation (5)Report Generation (4)
Metrickendalls tau (5)error rate (4)correlation with human judgments (4)kendall correlation with radiologists ranking (2)average similarity score (2)kendall s tau correlation (2)kendall s tau (2)
Splittest (1)
Showing 12 of 12 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | RadMatch (Opus 4.8) proposed | agreement with radiologist error counts (|τ_b|) | 0.79 | Radiology Report Evaluation · judge-model=Opus 4.8 | RadMatch: Auditable Radiology Report Evaluation via Finding-Level MatchingSource quoteL133: metric on each. With the Opus 4.8 model, it reaches |\tau_b|=0.79 on ReXVal, matching the agreement among radiologists themselves, and |\tau_b|=0.58 on the harder RadEvalExpert, more than doubling the best prior metric, while lexical and clinical-concept metrics collapse to |
| 2026 | RadMatch (Gemma 4 31B) proposed | agreement with radiologist error counts (|τ_b|) | 0.75 | Radiology Report Evaluation · params=31B · judge-model=Gemma 4 31B | RadMatch: Auditable Radiology Report Evaluation via Finding-Level MatchingSource quoteL134: near-zero. This level of agreement does not require a frontier proprietary judge. With the open-source Gemma 4 31B~\cite{gemma4} model, RadMatch reaches |\tau_b|=0.75 on ReXVal and 0.53 on RadEvalExpert, and can be run on-premise with a single 32\,GB consumer GPU in FP8, avoiding |
| 2025 | GEMA-Score proposed | Kendall coefficient | 0.69 | Radiology Report Evaluation | GEMA-Score: Granular Explainable Multi-Agent Score for Radiology Report EvaluationSource quoteL4: Automatic medical report generation has the potential to support clinical diagnosis, reduce the workload of radiologists, and demonstrate potential for enhancing diagnostic consistency. However, current evaluation metrics often fail to reflect the clinical reliability of generated reports. Early overlap-based methods focus on textual matches between predicted and ground-truth entities but miss fine-grained clinical details (e.g., anatomical location, severity). Some diagnostic metrics are limited by fixed vocabularies or templates, reducing their ability to capture diverse clinical expressions. LLM-based approaches further lack interpretable reasoning steps, making it hard to assess or trust their behavior in safety-critical settings. These limitations hinder the comprehensive assessment of the reliability of generated reports and pose risks in their selection for clinical use. Therefore, we propose a Granular Explainable Multi-Agent Score (GEMA-Score) in this paper, which conducts both objective quantification and subjective evaluation through a large language model-based multi-agent workflow. Our GEMA-Score parses structured reports and employs stable calculations through interactive exchanges of information among agents to assess disease diagnosis, location, severity, and uncertainty. Additionally, an LLM-based scoring agent evaluates completeness, readability, and clinical terminology while providing explanatory feedback. Extensive experiments validate that GEMA-Score achieves the highest correlation with human expert evaluations on a public dataset, demonstrating its effectiveness in clinical scoring (Kendall coefficient = 0.69 for ReXVal dataset and Kendall coefficient = 0.45 for RadEvalX dataset). The anonymous project demo is available at: \url{https://github.com/Zhenxuan-Zhang/GEMA_score}. |
| 2025 | CLEAR (GPT-4o, o1-mini), scalarized proposed | Pearson correlation with clinical judgment | 0.70 | Radiology Report Evaluation · models=GPT-4o, o1-mini | CLEAR: A Clinically Grounded Tabular Framework for Radiology Report EvaluationSource quoteL420: CLEAR (GPT-4o, o1-mini) │ 0.70 |
| 2025 | GEMA-Score baseline | Pearson correlation with clinical judgment | 0.70 | Radiology Report Evaluation | CLEAR: A Clinically Grounded Tabular Framework for Radiology Report EvaluationSource quoteL419: GEMA-Score~\cite{zhang2025gema} │ 0.70 |
| 2025 | GREEN baseline | Kendall’s Tau | 0.640 | Radiology Report Evaluation | RadReason: Radiology Report Evaluation Metric with Reasons and Sub-ScoresSource quoteL225: GREEN~\citep{ostmeier2024green} │ 0.640 │ -- |
| 2025 | RadCliQ-v1 baseline | Spearman | 0.816 | Radiology Report Evaluation | RadReason: Radiology Report Evaluation Metric with Reasons and Sub-ScoresSource quoteL224: RadCliQ-v1~\citep{yu2023evaluating} │ 0.631 │ 0.816 |
| 2025 | CheXprompt baseline | Kendall’s Tau | 0.750 | Radiology Report Evaluation · model-type=online | RadReason: Radiology Report Evaluation Metric with Reasons and Sub-ScoresSource quoteL232: CheXprompt~\citep{zambrano2025clinically} │ 0.750 │ -- |
| 2025 | FineRadScore baseline | Kendall’s Tau | 0.737 | Radiology Report Evaluation · model-type=online | RadReason: Radiology Report Evaluation Metric with Reasons and Sub-ScoresSource quoteL233: FineRadScore~\citep{huang2024fineradscore} │ 0.737 │ -- |
| 2024 | ReFINE proposed | Kendall’s Tau | 0.751 | Radiology Report Evaluation | ReFINE: A Reward-Based Framework for Interpretable and Nuanced Evaluation of Radiology Report GenerationSource quoteL132: ReFINE (Ours) │ 0.751 (4.0e-52) │ 0.910 (5.0e-76) |
| 2024 | RadCliQ | Kendall tau b correlation | 0.615 | Radiology Report Evaluation · split: test | FineRadScore: A Radiology Report Line-by-Line Evaluation Technique Generating Corrections with Severity ScoresSource quoteL299: RadCliQ │ 0.615 (95% CI, 0.450 0.749) |
| 2024 | GREEN baseline | Kendall’s Tau | 0.640 | Radiology Report Evaluation | ReFINE: A Reward-Based Framework for Interpretable and Nuanced Evaluation of Radiology Report GenerationSource quoteL131: GREEN~\cite{ostmeier2024green} │ 0.640 |