ReXVal · Report Evaluation
10 papers · 27 extracted observations · radiology report evaluation · Markdown · CSV · JSON API
Tasks on ReXValAll tasks (10)Radiology Report Evaluation (6)Medical Report Evaluation (2)Report Evaluation (1)Report Generation (1)
TaskRadiology Report Evaluation (12)Medical Report Evaluation (6)Report Evaluation (5)Report Generation (4)
Metrickendalls tau (5)error rate (4)correlation with human judgments (4)kendall correlation with radiologists ranking (2)average similarity score (2)kendall s tau correlation (2)kendall s tau (2)
Splittest (1)
Showing 5 of 5 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2024 | GPT-4, two-stages prompt proposed | Kendall's tau correlation | 0.7348 | Report Evaluation · model=GPT-4 · prompting=two-stage | LLM-RadJudge: Achieving Radiologist-Level Evaluation for X-Ray Report GenerationSource quoteL89: We evaluated both two-stages prompt and single-step prompt based on GPT-4. The results, as illustrated in Figure.\ref{fig:llms} (A) and (B), indicate an improvement associated with the two-stages prompting technique. Specifically, there was an increase in Kendall's tau correlation from 0.6933 to 0.7348, underscoring the efficacy of this approach. |
| 2024 | GPT-4, single-step prompt ablation | Kendall's tau correlation | 0.6933 | Report Evaluation · model=GPT-4 · prompting=single-step | LLM-RadJudge: Achieving Radiologist-Level Evaluation for X-Ray Report GenerationSource quoteL89: We evaluated both two-stages prompt and single-step prompt based on GPT-4. The results, as illustrated in Figure.\ref{fig:llms} (A) and (B), indicate an improvement associated with the two-stages prompting technique. Specifically, there was an increase in Kendall's tau correlation from 0.6933 to 0.7348, underscoring the efficacy of this approach. |
| 2024 | Mistral-medium baseline | Kendall's tau coefficient | 0.7286 | Report Evaluation · model=Mistral-medium | LLM-RadJudge: Achieving Radiologist-Level Evaluation for X-Ray Report GenerationSource quoteL99: We conducted a juxtaposition of the outputs produced by these LLMs against the annotations provided by radiologists from the ReXVal dataset and computed the Kendall's tau coefficient for each respective model, thereby assessing their concordance \cite{yu2023evaluating}. As delineated in Figure \ref{fig:llms}, panels (B) through (J), GPT-4-turbo emerged as the paragon, achieving the highest alignment with a Kendall's tau coefficient of 0.7348, closely tailed by Mistral-medium at 0.7286. The performance continuum then spans models such as Mixtral-8x7B, PALM2-bison, and Mistral-small, which exhibit Kendall's tau values ranging from 0.6455 to 0.6314. Models GPT-3.5-turbo and Gemini-pro hover around a Kendall's tau of approximately 0.58. In stark contrast, both Llama2 variants, Llama2-70b-chat and Llama2-13b-chat, demonstrate sub-optimal concordance. |
| 2024 | Radiologist inter-observer agreement (lower endpoint) baseline | Kendall's tau | 0.7352 | Report Evaluation · annotators=radiologists | LLM-RadJudge: Achieving Radiologist-Level Evaluation for X-Ray Report GenerationSource quoteL111: To further assess GPT-4's capabilities comparing with professional radiologists, we conducted an analysis of inter-observer consistency among the six radiologist annotators responsible for establishing the ground truth. We evaluated the concordance between each individual radiologist's assessments and the collective evaluations of the remaining five annotators. The resulting Kendall's tau values ranged from 0.7352 to 0.8248, indicating a high level of agreement among the radiologists. |
| 2024 | Radiologist inter-observer agreement (upper endpoint) baseline | Kendall's tau | 0.8248 | Report Evaluation · annotators=radiologists | LLM-RadJudge: Achieving Radiologist-Level Evaluation for X-Ray Report GenerationSource quoteL111: To further assess GPT-4's capabilities comparing with professional radiologists, we conducted an analysis of inter-observer consistency among the six radiologist annotators responsible for establishing the ground truth. We evaluated the concordance between each individual radiologist's assessments and the collective evaluations of the remaining five annotators. The resulting Kendall's tau values ranged from 0.7352 to 0.8248, indicating a high level of agreement among the radiologists. |