ReXVal · Report Evaluation

10 papers · 27 extracted observations · radiology report evaluation · Markdown · CSV · JSON API

Showing 5 of 5 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024GPT-4, two-stages prompt proposedKendall's tau correlation0.7348Report Evaluation · model=GPT-4 · prompting=two-stageLLM-RadJudge: Achieving Radiologist-Level Evaluation for X-Ray Report Generation
Source quote
L89: We evaluated both two-stages prompt and single-step prompt based on GPT-4. The results, as illustrated in Figure.\ref{fig:llms} (A) and (B), indicate an improvement associated with the two-stages prompting technique. Specifically, there was an increase in Kendall's tau correlation from 0.6933 to 0.7348, underscoring the efficacy of this approach.
2024GPT-4, single-step prompt ablationKendall's tau correlation0.6933Report Evaluation · model=GPT-4 · prompting=single-stepLLM-RadJudge: Achieving Radiologist-Level Evaluation for X-Ray Report Generation
Source quote
L89: We evaluated both two-stages prompt and single-step prompt based on GPT-4. The results, as illustrated in Figure.\ref{fig:llms} (A) and (B), indicate an improvement associated with the two-stages prompting technique. Specifically, there was an increase in Kendall's tau correlation from 0.6933 to 0.7348, underscoring the efficacy of this approach.
2024Mistral-medium baselineKendall's tau coefficient0.7286Report Evaluation · model=Mistral-mediumLLM-RadJudge: Achieving Radiologist-Level Evaluation for X-Ray Report Generation
Source quote
L99: We conducted a juxtaposition of the outputs produced by these LLMs against the annotations provided by radiologists from the ReXVal dataset and computed the Kendall's tau coefficient for each respective model, thereby assessing their concordance \cite{yu2023evaluating}. As delineated in Figure \ref{fig:llms}, panels (B) through (J), GPT-4-turbo emerged as the paragon, achieving the highest alignment with a Kendall's tau coefficient of 0.7348, closely tailed by Mistral-medium at 0.7286. The performance continuum then spans models such as Mixtral-8x7B, PALM2-bison, and Mistral-small, which exhibit Kendall's tau values ranging from 0.6455 to 0.6314. Models GPT-3.5-turbo and Gemini-pro hover around a Kendall's tau of approximately 0.58. In stark contrast, both Llama2 variants, Llama2-70b-chat and Llama2-13b-chat, demonstrate sub-optimal concordance.
2024Radiologist inter-observer agreement (lower endpoint) baselineKendall's tau0.7352Report Evaluation · annotators=radiologistsLLM-RadJudge: Achieving Radiologist-Level Evaluation for X-Ray Report Generation
Source quote
L111: To further assess GPT-4's capabilities comparing with professional radiologists, we conducted an analysis of inter-observer consistency among the six radiologist annotators responsible for establishing the ground truth. We evaluated the concordance between each individual radiologist's assessments and the collective evaluations of the remaining five annotators. The resulting Kendall's tau values ranged from 0.7352 to 0.8248, indicating a high level of agreement among the radiologists.
2024Radiologist inter-observer agreement (upper endpoint) baselineKendall's tau0.8248Report Evaluation · annotators=radiologistsLLM-RadJudge: Achieving Radiologist-Level Evaluation for X-Ray Report Generation
Source quote
L111: To further assess GPT-4's capabilities comparing with professional radiologists, we conducted an analysis of inter-observer consistency among the six radiologist annotators responsible for establishing the ground truth. We evaluated the concordance between each individual radiologist's assessments and the collective evaluations of the remaining five annotators. The resulting Kendall's tau values ranged from 0.7352 to 0.8248, indicating a high level of agreement among the radiologists.