# ReXVal (`rexval`)

- **Canonical ID**: `bmk_e5405e28e9626650`
- **Task**: radiology-report-evaluation · **Modality**: unspecified
- **Coverage**: 10 papers · 27 observations
- **Tasks Evaluated**: Radiology Report Evaluation (`?task=radiology-report-evaluation`, 6 papers), Medical Report Evaluation (`?task=medical-report-evaluation`, 2 papers), Report Evaluation (`?task=report-evaluation`, 1 papers), Report Generation (`?task=report-generation`, 1 papers)

## Recent Extracted Observations

| Year | Method | Role | Metric | Score | Split | Regime | Paper | Verbatim Quote |
| --- | --- | --- | --- | ---: | --- | --- | --- | --- |
| 2026 | RadMatch (Opus 4.8) | proposed | agreement with radiologist error counts (|τ_b|) | 0.79 | - | - | [RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching](/work/radmatch-auditable-radiology-report-evaluation-via-finding) | metric on each. With the Opus 4.8 model, it reaches \|\tau_b\|=0.79 on ReXVal, matching the agreement among radiologists themselves, and \|\tau_b\|=0.58 on the  |
| 2026 | RadMatch (Gemma 4 31B) | proposed | agreement with radiologist error counts (|τ_b|) | 0.75 | - | - | [RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching](/work/radmatch-auditable-radiology-report-evaluation-via-finding) | near-zero. This level of agreement does not require a frontier proprietary judge. With the open-source Gemma 4 31B~\cite{gemma4} model, RadMatch reaches \|\tau_ |
| 2025 | GEMA-Score | proposed | Kendall coefficient | 0.69 | - | - | [GEMA-Score: Granular Explainable Multi-Agent Score for Radiology Report Evaluation](/work/gema-score-granular-explainable-multi-agent-score) | Automatic medical report generation has the potential to support clinical diagnosis, reduce the workload of radiologists, and demonstrate potential for enhancin |
| 2025 | CLEAR (GPT-4o, o1-mini), scalarized | proposed | Pearson correlation with clinical judgment | 0.70 | - | - | [CLEAR: A Clinically Grounded Tabular Framework for Radiology Report Evaluation](/work/clear-a-clinically-grounded-tabular-framework-for-radiology) | CLEAR (GPT-4o, o1-mini) & 0.70 |
| 2025 | GEMA-Score | baseline | Pearson correlation with clinical judgment | 0.70 | - | - | [CLEAR: A Clinically Grounded Tabular Framework for Radiology Report Evaluation](/work/clear-a-clinically-grounded-tabular-framework-for-radiology) | GEMA-Score~\cite{zhang2025gema} & 0.70 |
| 2025 | GREEN | baseline | Kendall’s Tau | 0.640 | - | - | [RadReason: Radiology Report Evaluation Metric with Reasons and Sub-Scores](/work/radreason-radiology-report-evaluation-metric-with-reasons) | GREEN~\citep{ostmeier2024green} & 0.640 & -- |
| 2025 | RadCliQ-v1 | baseline | Spearman | 0.816 | - | - | [RadReason: Radiology Report Evaluation Metric with Reasons and Sub-Scores](/work/radreason-radiology-report-evaluation-metric-with-reasons) | RadCliQ-v1~\citep{yu2023evaluating} & 0.631 & 0.816 |
| 2025 | CheXprompt | baseline | Kendall’s Tau | 0.750 | - | - | [RadReason: Radiology Report Evaluation Metric with Reasons and Sub-Scores](/work/radreason-radiology-report-evaluation-metric-with-reasons) | CheXprompt~\citep{zambrano2025clinically} & 0.750 & -- |
| 2025 | FineRadScore | baseline | Kendall’s Tau | 0.737 | - | - | [RadReason: Radiology Report Evaluation Metric with Reasons and Sub-Scores](/work/radreason-radiology-report-evaluation-metric-with-reasons) | FineRadScore~\citep{huang2024fineradscore} & 0.737 & -- |
| 2024 | ReFINE | proposed | Kendall’s Tau | 0.751 | - | - | [ReFINE: A Reward-Based Framework for Interpretable and Nuanced Evaluation of Radiology Report Generation](/work/refine-a-reward-based-framework-for-interpretable-aa6v) | ReFINE (Ours) & 0.751 (4.0e-52) & 0.910 (5.0e-76) |
| 2024 | RadCliQ | unclear | Kendall tau b correlation | 0.615 | test | - | [FineRadScore: A Radiology Report Line-by-Line Evaluation Technique Generating Corrections with Severity Scores](/work/fineradscore-a-radiology-report-line-by-line-evaluation) | RadCliQ & 0.615 (95% CI, 0.450 0.749) |
| 2024 | GREEN | baseline | Kendall’s Tau | 0.640 | - | - | [ReFINE: A Reward-Based Framework for Interpretable and Nuanced Evaluation of Radiology Report Generation](/work/refine-a-reward-based-framework-for-interpretable-aa6v) | GREEN~\cite{ostmeier2024green} & 0.640 & - |