EchoNet-Dynamic · Ejection Fraction Estimation

32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Ejection Fraction Estimation.

3.94.14.34.520222023EchoCoTr: 3.95 (2022)EchoGNN: 4.45 (2022)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 13 of 13 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025HSS-Net (full method) proposedcorr (Pearson correlation for EF estimation)84.50Ejection Fraction EstimationHierarchical Spatio-Temporal Segmentation Network for Ejection Fraction Estimation in Echocardiography Videos
Source quote
L159: HSS-Net~(Ours) │ \textBF{90.47} │ \textBF{2.43±5.02} │ \textBF{93.89} │ \textBF{11.29} │ \textBF{84.50} │ \textBF{0.95±6.75} │ \textBF{92.67} │ \textBF{2.66}
2025Single-Input Fusion proposedRMSE7.02Ejection Fraction Estimation · split: test · architecture=Single-Input FusionInvestigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography Videos
Source quote
L285: Layer Normalization. More pronounced gains were observed with the Single-Input and Dual-Input Fusion architectures, which achieved test RMSE values of 7.02 and 7.64, respectively, both when paired with
2025Dual-Input Fusion proposedRMSE7.64Ejection Fraction Estimation · split: test · architecture=Dual-Input FusionInvestigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography Videos
Source quote
L285: Layer Normalization. More pronounced gains were observed with the Single-Input and Dual-Input Fusion architectures, which achieved test RMSE values of 7.02 and 7.64, respectively, both when paired with
2025I3D-mini (B2) ablationRMSE6.7954Ejection Fraction Estimation · variant=B2 · architecture=I3D-mini · conv2-kernel=3×3×3Investigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography Videos
Source quote
L169: 6.7954
2025I3D-mini (B1) ablationRMSE7.0906Ejection Fraction Estimation · variant=B1 · architecture=I3D-mini · conv2-kernel=1×1×1Investigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography Videos
Source quote
L165: 7.0906
2023GEMTrans proposedMAE4.15 mmEjection Fraction Estimation · split: test · video-setting=single-video A4C/AP4GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular Diagnosis
Source quote
L132: 4.15
2023UCVME proposedMAE4.37Ejection Fraction Estimation · semi-supervised · labeled-data=25%Semi-Supervised Deep Regression with Uncertainty Consistency and Variational Model Ensembling via Bayesian Neural Networks
Source quote
L441: Our method consistently achieves the best results for all settings by significant margins. We are also able to achieve an MAE of 4.37 using a quarter of the labels, which is only a relative 5.8% higher than the 4.13 MAE achieved by Ouyang et al. on fully labeled data. Our proposed method therefore reduces the number of labels required for training which is highly valuable for medical regression tasks.
2023Thomas et al. [24] baselineMAE4.23 mmEjection Fraction Estimation · split: test · video-setting=single-video A4C/AP4GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular Diagnosis
Source quote
L122: 4.23
2022EchoCoTr proposedMAE3.95Ejection Fraction Estimation · modality=echocardiography videoEchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal Echocardiography
Source quote
L4: Learning spatiotemporal features is an important task for efficient video understanding especially in medical images such as echocardiograms. Convolutional neural networks (CNNs) and more recent vision transformers (ViTs) are the most commonly used methods with limitations per each. CNNs are good at capturing local context but fail to learn global information across video frames. On the other hand, vision transformers can incorporate global details and long sequences but are computationally expensive and typically require more data to train. In this paper, we propose a method that addresses the limitations we typically face when training on medical video data such as echocardiographic scans. The algorithm we propose (EchoCoTr) utilizes the strength of vision transformers and CNNs to tackle the problem of estimating the left ventricular ejection fraction (LVEF) on ultrasound videos. We demonstrate how the proposed method outperforms state-of-the-art work to-date on the EchoNet-Dynamic dataset with MAE of 3.95 and R^2 of 0.82. These results show noticeable improvement compared to all published research. In addition, we show extensive ablations and comparisons with several algorithms, including ViT and BERT. The code is available
2022EchoCoTr proposedR^20.82Ejection Fraction Estimation · modality=echocardiography videoEchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal Echocardiography
Source quote
L4: Learning spatiotemporal features is an important task for efficient video understanding especially in medical images such as echocardiograms. Convolutional neural networks (CNNs) and more recent vision transformers (ViTs) are the most commonly used methods with limitations per each. CNNs are good at capturing local context but fail to learn global information across video frames. On the other hand, vision transformers can incorporate global details and long sequences but are computationally expensive and typically require more data to train. In this paper, we propose a method that addresses the limitations we typically face when training on medical video data such as echocardiographic scans. The algorithm we propose (EchoCoTr) utilizes the strength of vision transformers and CNNs to tackle the problem of estimating the left ventricular ejection fraction (LVEF) on ultrasound videos. We demonstrate how the proposed method outperforms state-of-the-art work to-date on the EchoNet-Dynamic dataset with MAE of 3.95 and R^2 of 0.82. These results show noticeable improvement compared to all published research. In addition, we show extensive ablations and comparisons with several algorithms, including ViT and BERT. The code is available
2022EchoGNN proposedMAE4.45Ejection Fraction EstimationEchoGNN: Explainable Ejection Fraction Estimation with Graph Neural Networks
Source quote
L142: 0.76 4.45
2022Bayesian [12] baselineMAE4.46Ejection Fraction EstimationEchoGNN: Explainable Ejection Fraction Estimation with Graph Neural Networks
Source quote
L136: 0.75 4.46
2021UVT (M., mirror video sampling) proposed non-standard sliceMAE5.95Ejection Fraction Estimation · video-sampling=mirrorUltrasound Video Transformers for Cardiac Ejection Fraction Estimation
Source quote
L114: M. (ours) │ 5.32 (4.90) │ 7.23 │ 0.64 │ 5.95 (5.90) │ 8.38 │ 0.52