EchoNet-Dynamic · Binary Classification

32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025Ours (Temporal, End-to-end, Oracle) proposed non-standard sliceAUROC0.88Binary Classification · resolution=32×32 · frames=10 · setting=oracleTemporal Representation Learning for Real-Time Ultrasound Analysis
Source quote
L169: Ours (Temporal, End-to-end, Oracle) │ \sim10,000 │ \sim8M │ 10×32×32 │ 0.89 │ 0.84 │ 0.88
2025Ours (Temporal, End-to-end, Oracle) proposed non-standard sliceF10.89Binary Classification · resolution=32×32 · frames=10 · setting=oracleTemporal Representation Learning for Real-Time Ultrasound Analysis
Source quote
L169: Ours (Temporal, End-to-end, Oracle) │ \sim10,000 │ \sim8M │ 10×32×32 │ 0.89 │ 0.84 │ 0.88
2025Ours (Temporal, End-to-end, Oracle) proposed non-standard sliceAccuracy0.84Binary Classification · resolution=32×32 · frames=10 · setting=oracleTemporal Representation Learning for Real-Time Ultrasound Analysis
Source quote
L169: Ours (Temporal, End-to-end, Oracle) │ \sim10,000 │ \sim8M │ 10×32×32 │ 0.89 │ 0.84 │ 0.88
2025ECHO-VISION-FM baselineAccuracy0.89Binary Classification · fine-tuned · backbone=ViT-B · resolution=224×224 · frames=16 · pretraining-data=40% of MIMIC-IV-ECHOTemporal Representation Learning for Real-Time Ultrasound Analysis
Source quote
L168: ECHO-VISION-FM │ \sim200,000 │ \sim98M │ 16×224×224 │ 0.93 │ 0.89 │ 0.93