EchoNet-Dynamic
32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API
Tasks on EchoNet-DynamicAll tasks (32)Image Segmentation (11)Ejection Fraction Estimation (7)Ejection Fraction Regression (2)Image Generation (2)Video Generation (2)Binary Classification (1)Cardiac Function Estimation (1)Classification (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Ejection Fraction Estimation.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | EchoCoTr SOTA frontier | 3.95 | 2022-01-01 | modality=echocardiography video · LVEF estimation on ultrasound videos; split and other evaluation conditions are not s… | EchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal EchocardiographySource quoteLearning spatiotemporal features is an important task for efficient video understanding especially in medical images such as echocardiograms. Convolutional neural networks (CNNs) and more recent vision transformers (ViTs) are the most commonly used methods with limitations per each. CNNs are good at capturing local context but fail to learn global information across video frames. On the other hand, vision transformers can incorporate global details and long sequences but are computationally expensive and typically require more data to train. In this paper, we propose a method that addresses the limitations we typically face when training on medical video data such as echocardiographic scans. The algorithm we propose (EchoCoTr) utilizes the strength of vision transformers and CNNs to tackle the problem of estimating the left ventricular ejection fraction (LVEF) on ultrasound videos. We demonstrate how the proposed method outperforms state-of-the-art work to-date on the EchoNet-Dynamic dataset with MAE of 3.95 and R^2 of 0.82. These results show noticeable improvement compared to all published research. In addition, we show extensive ablations and comparisons with several algorithms, including ViT and BERT. The code is available |
| 2 | EchoGNN | 4.45 | 2022-08-01 | EF prediction; Table 1. | EchoGNN: Explainable Ejection Fraction Estimation with Graph Neural NetworksSource quote0.76 4.45 |
Other primary task on EchoNet-Dynamic: Image Generation · FID ↓ (2 papers)
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ADM-EDM with Discriminator Guidance (DG) SOTA frontier | 2.6 | 2023-11-01 | resolution=64×64 · NFE=59 · sampler=EDM · samples=50000 per epoch · DG-vector-scaling=2 · FID evaluated over 50,000 samples per epoch. A UNet-encoder discriminator was trained… | Exploring the Hyperparameter Space of Image Diffusion Models for Echocardiogram GenerationSource quoteOnce our discriminator is trained, we plug it in the reverse diffusion process as described in~\cite{kim2023refining}, and samples 50,000 for every epoch, in order to find the best performing one. We find that, for the best epoch with the nest set of hyperparameters, the FID improves from 3.75 to 2.60, showing the significance of DG. We use 30 (59 NFE) sampling steps, a weight of 5 for the first order EDM prediction, no guidance for the correction (weight 0) and a scaling of 2 for the Discriminator Guidance vectors. |
| 2 | MCDM (ReID+Flow) | 47.1 | 2025-12-01 | variant=ReID+Flow · video-length=64-frames · 64-frame synthetic videos; label-free, motion-conditioned MCDM using re-identificatio… | Label-free Motion-Conditioned Diffusion Model for Cardiac Ultrasound SynthesisSource quotemotion │ \(×\) │ MCDM (ReID+Flow) │ 47.1 │ 225.1 │ -- │ \textbf{2.19-± 0.06} |
Other primary task on EchoNet-Dynamic: Image Segmentation · MAE ↓ · test (2 papers)
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MCSDR (vision-only) SOTA frontier | 3.76 | 2026-02-01 | Test set; evaluated in vision-only mode to avoid label leakage from derived text attr… | Generative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography VideoSource quoteDespite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89). |
| 2 | CoReEcho SOTA frontier | 3.9 | 2024-01-01 | EF regression; predictions from three sampled clips averaged for each video. | CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography AnalysisSource quoteComparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.} |
Other primary task on EchoNet-Dynamic: Image Segmentation · mDice ↑ (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SAMUS SOTA frontier | 91.79 | 2024-01-01 | EchoNet-Dynamic videos have labels only for end-systolic and end-diastolic phases; ev… | MemSAM: Taming Segment Anything Model for Echocardiography Video SegmentationSource quote91.79 |
| 2 | EchoONE | 88.36 | 2025-01-01 | training=not used · evaluation=external · External evaluation; EchoNet-Dynamic was not used for training. | EchoONE: Segmenting Multiple Echocardiography Planes in One ModelSource quoteEchoONE │ 73.94 │ 59.31 │ 88.36 │ 79.65 |
TaskImage Segmentation (24)Ejection Fraction Estimation (13)Video Generation (6)Ejection Fraction Regression (5)Left Ventricular Ejection Fraction Prediction (5)Binary Classification (4)Video Segmentation (4)
Showing 29 of 29 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | MCSDR (vision-only) | MAE | 3.76 | Image Segmentation · split: test | Generative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography VideoSource quoteL191: Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89). |
| 2026 | PanEcho baseline | MAE | 5.35 | Image Segmentation · split: test | Generative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography VideoSource quoteL191: Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89). |
| 2025 | EchoGPT proposed | AUC (40%) | 0.9519 | Left Ventricular Ejection Fraction Prediction · split: test | EchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram VideosSource quoteL244: Specifically, EchoGPT achieved AUC values of 0.9519, |
| 2025 | EchoGPT proposed | AUC (50%) | 0.9221 | Left Ventricular Ejection Fraction Prediction · split: test | EchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram VideosSource quoteL245: 0.9221, and 0.8475 for the thresholds of 40%, 50%, and |
| 2025 | EchoGPT proposed | AUC (70%) | 0.8475 | Left Ventricular Ejection Fraction Prediction · split: test | EchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram VideosSource quoteL245: 0.9221, and 0.8475 for the thresholds of 40%, 50%, and |
| 2025 | EchoGPT proposed | R² | 0.6848 | Left Ventricular Ejection Fraction Prediction · split: test | EchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram VideosSource quoteL247: 50%, and above 70%. In terms of the R² score, EchoGPT reached 0.6848, implying that our model accounts for approximately 68.48% of the variability in ejection fraction, the highest proportion among all compared models. Furthermore, EchoGPT’s mean absolute error (MAE) was 7.5934, the lowest among all models, which further corroborates the high precision of EchoGPT in predicting left ventricular ejection fraction. In comparison, other models such as EchoCLIP, |
| 2025 | EchoGPT proposed | MAE (Mean Absolute Error) | 7.5934 | Left Ventricular Ejection Fraction Prediction · split: test | EchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram VideosSource quoteL247: 50%, and above 70%. In terms of the R² score, EchoGPT reached 0.6848, implying that our model accounts for approximately 68.48% of the variability in ejection fraction, the highest proportion among all compared models. Furthermore, EchoGPT’s mean absolute error (MAE) was 7.5934, the lowest among all models, which further corroborates the high precision of EchoGPT in predicting left ventricular ejection fraction. In comparison, other models such as EchoCLIP, |
| 2025 | Single-Input Fusion proposed | RMSE | 7.02 | Ejection Fraction Estimation · split: test · architecture=Single-Input Fusion | Investigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography VideosSource quoteL285: Layer Normalization. More pronounced gains were observed with the Single-Input and Dual-Input Fusion architectures, which achieved test RMSE values of 7.02 and 7.64, respectively, both when paired with |
| 2025 | Dual-Input Fusion proposed | RMSE | 7.64 | Ejection Fraction Estimation · split: test · architecture=Dual-Input Fusion | Investigating Deep Learning Models for Ejection Fraction Estimation from Echocardiography VideosSource quoteL285: Layer Normalization. More pronounced gains were observed with the Single-Input and Dual-Input Fusion architectures, which achieved test RMSE values of 7.02 and 7.64, respectively, both when paired with |
| 2025 | VidFuncta only φ ablation | MAE | 6.11 | Ejection Fraction Prediction · split: test · evaluation=5-fold | VidFuncta: Towards Generalizable Neural Representations for Ultrasound VideosSource quoteL160: VidFuncta only \phi │ 6.11 │ 8.35 │ 0.56 │ 62.5 │ 70.3 │ 65.6 │ 64.6 │ 68.1 │ 63.0 |
| 2025 | PocovidNet on 𝒱 baseline | MAE | 4.34 | Ejection Fraction Prediction · split: test · input=original video · evaluation=5-fold | VidFuncta: Towards Generalizable Neural Representations for Ultrasound VideosSource quoteL169: PocovidNet on \mathcal{V} │ 4.34 │ 5.84 │ 0.77 │ 86.7 │ 88.2 │ 93.1 │ 76.1 │ 80.1 │ 82.3 |
| 2025 | PanEcho baseline | LV EF MAE | 5.79 | Regression · split: test · 0-shot | CardioBench: Do Echocardiography Foundation Models Generalize Beyond the Lab?Source quoteL77: PanEcho \cite{holste2025panecho} {\textcolor{customblue}{\scalebox{0.6}{\ding{108}}}} │ 5.79 │ 11.63 │ 9.10 │ 0.36 │ 0.21 │ 0.18 │ 58.90 │ 30.50 │ 24.30 │ 20.52 |
| 2024 | Adaptive (w/ aug & LD) proposed non-standard slice | Dice score (LV) | 0.910 | Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=used | Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial LabellingSource quoteL117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689 |
| 2024 | Adaptive (w/ aug & LD) proposed non-standard slice | Dice score (LVM) | 0.518 | Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=used | Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial LabellingSource quoteL117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689 |
| 2024 | Adaptive (w/ aug & LD) proposed non-standard slice | Dice score (LA) | 0.689 | Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=used | Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial LabellingSource quoteL117: Adaptive (w/ aug \ │ LD) │ 0.910 │ 0.518 │ 0.689 |
| 2024 | Adaptive (w/ aug) ablation non-standard slice | Dice score (LV) | 0.892 | Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=not used | Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial LabellingSource quoteL116: Adaptive (w/ aug) │ 0.892 │ 0.319 │ 0.553 |
| 2024 | Adaptive (w/ aug) ablation non-standard slice | Dice score (LVM) | 0.319 | Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=not used | Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial LabellingSource quoteL116: Adaptive (w/ aug) │ 0.892 │ 0.319 │ 0.553 |
| 2024 | Adaptive (w/ aug) ablation non-standard slice | Dice score (LA) | 0.553 | Image Segmentation · split: test · subset=20 random images · augmentation=used · label-dropout=not used | Label Dropout: Improved Deep Learning Echocardiography Segmentation Using Multiple Datasets with Domain Shift and Partial LabellingSource quoteL116: Adaptive (w/ aug) │ 0.892 │ 0.319 │ 0.553 |
| 2023 | SupReMix proposed | MAE | 4.02% | Cardiac Function Estimation · split: test · linear-probe · pretraining-epochs=200 · linear-probe-epochs=100 | SupReMix: Supervised contrastive learning for medical imaging regression with mixupSource quoteL228: We compare SupReMix against both classification-based (SimCLR \citep{chen2019self}, SupCon \citep{khosla2020supervised}) and regression-based (AdaCon \citep{dai2021adaptive}, RnC \citep{zha2023rank}) representation learning methods across six medical imaging regression datasets spanning different modalities (MRI, X-ray, ultrasound, and PET). As shown in Figure \ref{fig:mae_comparision}, SupReMix consistently achieves lower MAE than all baseline methods. Taking bone age prediction on RSNA as an example, SupReMix reduces the MAE to 4.08 months compared to the classification-based method SupCon (6.79 months). The performance gains are particularly notable in challenging tasks such as cardiac function estimation, where SupReMix achieves an MAE of 4.02 compared to SupCon's 5.88. Moreover, we observe that SupReMix consistently outperforms vanilla regression (shown in dashed line). Additional performance metrics including Mean Squared Error (MSE), correlation coefficient (\rho), and Geometric Mean (GM) error are provided in Tables \ref{table1}, \ref{table2}, \ref{table3}, \ref{table4}, \ref{table5}, \ref{table6}. |
| 2023 | GEMTrans proposed | MAE | 4.15 mm | Ejection Fraction Estimation · split: test · video-setting=single-video A4C/AP4 | GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular DiagnosisSource quoteL132: 4.15 |
| 2023 | SimLVSeg-3D proposed | overall DSC | 93.32% | Video Segmentation · split: test · frames=32 | UniLVSeg: Unified Left Ventricular Segmentation with Sparsely Annotated Echocardiogram Videos through Self-Supervised Temporal Masking and Weakly Supervised TrainingSource quoteL123: \texttt{SimLVSeg}{} outperforms recent state-of-the-art approaches (\cite{ouyang2020video, Isensee2021-yh, weak_supervision}) on the EchoNet test set, as shown in Table \ref{tab_main} and Figure \ref{fig_comparisons}. We compare our method with the approach proposed by the EchoNet dataset publisher \cite{ouyang2020video}, the famous nnU-Net \cite{Isensee2021-yh}, which can perform better than specially designed echocardiography networks as mentioned in \cite{sarina_lightweight}, and the method achieving the highest dice similarity coefficient (DSC) on the test set \cite{weak_supervision}. \texttt{SimLVSeg}{} with 3D U-Net (\texttt{SimLVSeg}{}-3D) results in 93.32% overall DSC, and \texttt{SimLVSeg}{}-SI approach shows on-par performance. Confidence interval (CI) analysis further shows no overlap between the 95% CI of \texttt{SimLVSeg}{} with other state-of-the-art solutions, indicating that our improvements hold statistical significance over those methods with a p-value of less than 0.05. The \texttt{SimLVSeg}{}-3D was trained with 32 frames sampled consecutively, while the \texttt{SimLVSeg}{}-SI was trained with 16 frames sampled at every 5\textsuperscript{th} frame. This experiment shows that a video segmentation network trained in a weakly-supervised manner is capable of segmenting the LV with a 3.8x lower computational cost compared to \cite{weak_supervision}. |
| 2023 | Proposed M-mode methods (E2E & CL, M=10) proposed | Time, Test | 21.1 msec/sample | Ejection Fraction Regression · split: test · variant=E2E & CL, M=10 · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=64 | M(otion)-mode Based Prediction of Ejection Fraction using EchocardiogramsSource quoteL286: E2E \ │ CL │ 64 │ 11.7 │ 1.568 │ 1.330 │ 24.5 │ 21.1 │ 1.013 │ 0.120 |
| 2023 | Proposed M-mode methods (E2E & CL, M=10) proposed | Memory, Test | 0.120 GB/B | Ejection Fraction Regression · split: test · variant=E2E & CL, M=10 · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=64 | M(otion)-mode Based Prediction of Ejection Fraction using EchocardiogramsSource quoteL286: E2E \ │ CL │ 64 │ 11.7 │ 1.568 │ 1.330 │ 24.5 │ 21.1 │ 1.013 │ 0.120 |
| 2023 | SupCon baseline | MAE | 5.88% | Cardiac Function Estimation · split: test · linear-probe · pretraining-epochs=200 · linear-probe-epochs=100 | SupReMix: Supervised contrastive learning for medical imaging regression with mixupSource quoteL228: We compare SupReMix against both classification-based (SimCLR \citep{chen2019self}, SupCon \citep{khosla2020supervised}) and regression-based (AdaCon \citep{dai2021adaptive}, RnC \citep{zha2023rank}) representation learning methods across six medical imaging regression datasets spanning different modalities (MRI, X-ray, ultrasound, and PET). As shown in Figure \ref{fig:mae_comparision}, SupReMix consistently achieves lower MAE than all baseline methods. Taking bone age prediction on RSNA as an example, SupReMix reduces the MAE to 4.08 months compared to the classification-based method SupCon (6.79 months). The performance gains are particularly notable in challenging tasks such as cardiac function estimation, where SupReMix achieves an MAE of 4.02 compared to SupCon's 5.88. Moreover, we observe that SupReMix consistently outperforms vanilla regression (shown in dashed line). Additional performance metrics including Mean Squared Error (MSE), correlation coefficient (\rho), and Geometric Mean (GM) error are provided in Tables \ref{table1}, \ref{table2}, \ref{table3}, \ref{table4}, \ref{table5}, \ref{table6}. |
| 2023 | Thomas et al. [24] baseline | MAE | 4.23 mm | Ejection Fraction Estimation · split: test · video-setting=single-video A4C/AP4 | GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular DiagnosisSource quoteL122: 4.23 |
| 2023 | EchoNet baseline | Time, Test | 123.7 msec/sample | Ejection Fraction Regression · split: test · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=20 | M(otion)-mode Based Prediction of Ejection Fraction using EchocardiogramsSource quoteL285: EchoNet │ 20 │ 31.5 │ 2.898 │ 2.474 │ 144.9 │ 123.7 │ 5.294 │ 1.187 |
| 2023 | EchoNet baseline | Memory, Test | 1.187 GB/B | Ejection Fraction Regression · split: test · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=20 | M(otion)-mode Based Prediction of Ejection Fraction using EchocardiogramsSource quoteL285: EchoNet │ 20 │ 31.5 │ 2.898 │ 2.474 │ 144.9 │ 123.7 │ 5.294 │ 1.187 |
| 2021 | UVT (M./Reg., ours) proposed | Average frame distance (aFD) | 3.35 frames | End Systolic Frame Detection · split: test · video-sampling=mirror/regular | Ultrasound Video Transformers for Cardiac Ejection Fraction EstimationSource quoteL102: M./Reg. (ours) │ 0.08 (1.53) │ 0.15 (1.89) │ 3.35 (6.79) │ 7.17 (12.92) │ 6 |
| 2021 | UVT (M./Reg., ours) proposed | Average frame distance (aFD) | 7.17 frames | End Diastolic Frame Detection · split: test · video-sampling=mirror/regular | Ultrasound Video Transformers for Cardiac Ejection Fraction EstimationSource quoteL102: M./Reg. (ours) │ 0.08 (1.53) │ 0.15 (1.89) │ 3.35 (6.79) │ 7.17 (12.92) │ 6 |