EchoNet-Dynamic · Ejection Fraction Regression

32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2023Proposed M-mode methods (E2E & CL, M=10) proposedTime, Test21.1 msec/sampleEjection Fraction Regression · split: test · variant=E2E & CL, M=10 · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=64M(otion)-mode Based Prediction of Ejection Fraction using Echocardiograms
Source quote
L286: E2E \ │ CL │ 64 │ 11.7 │ 1.568 │ 1.330 │ 24.5 │ 21.1 │ 1.013 │ 0.120
2023Proposed M-mode methods (E2E & CL, M=10) proposedMemory, Test0.120 GB/BEjection Fraction Regression · split: test · variant=E2E & CL, M=10 · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=64M(otion)-mode Based Prediction of Ejection Fraction using Echocardiograms
Source quote
L286: E2E \ │ CL │ 64 │ 11.7 │ 1.568 │ 1.330 │ 24.5 │ 21.1 │ 1.013 │ 0.120
2023EchoNet baselineTime, Test123.7 msec/sampleEjection Fraction Regression · split: test · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=20M(otion)-mode Based Prediction of Ejection Fraction using Echocardiograms
Source quote
L285: EchoNet │ 20 │ 31.5 │ 2.898 │ 2.474 │ 144.9 │ 123.7 │ 5.294 │ 1.187
2023EchoNet baselineMemory, Test1.187 GB/BEjection Fraction Regression · split: test · hardware=4 NVIDIA GeForce RTX 2080 Ti GPUs · batch_size=20M(otion)-mode Based Prediction of Ejection Fraction using Echocardiograms
Source quote
L285: EchoNet │ 20 │ 31.5 │ 2.898 │ 2.474 │ 144.9 │ 123.7 │ 5.294 │ 1.187