EchoNet-Dynamic · Left Ventricular Ejection Fraction Prediction
32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API
Tasks on EchoNet-DynamicAll tasks (32)Image Segmentation (11)Ejection Fraction Estimation (7)Ejection Fraction Regression (2)Image Generation (2)Video Generation (2)Binary Classification (1)Cardiac Function Estimation (1)Classification (1)
TaskImage Segmentation (24)Ejection Fraction Estimation (13)Video Generation (6)Ejection Fraction Regression (5)Left Ventricular Ejection Fraction Prediction (5)Binary Classification (4)Video Segmentation (4)
Showing 5 of 5 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | EchoGPT proposed | AUC (40%) | 0.9519 | Left Ventricular Ejection Fraction Prediction · split: test | EchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram VideosSource quoteL244: Specifically, EchoGPT achieved AUC values of 0.9519, |
| 2025 | EchoGPT proposed | AUC (50%) | 0.9221 | Left Ventricular Ejection Fraction Prediction · split: test | EchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram VideosSource quoteL245: 0.9221, and 0.8475 for the thresholds of 40%, 50%, and |
| 2025 | EchoGPT proposed | AUC (70%) | 0.8475 | Left Ventricular Ejection Fraction Prediction · split: test | EchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram VideosSource quoteL245: 0.9221, and 0.8475 for the thresholds of 40%, 50%, and |
| 2025 | EchoGPT proposed | R² | 0.6848 | Left Ventricular Ejection Fraction Prediction · split: test | EchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram VideosSource quoteL247: 50%, and above 70%. In terms of the R² score, EchoGPT reached 0.6848, implying that our model accounts for approximately 68.48% of the variability in ejection fraction, the highest proportion among all compared models. Furthermore, EchoGPT’s mean absolute error (MAE) was 7.5934, the lowest among all models, which further corroborates the high precision of EchoGPT in predicting left ventricular ejection fraction. In comparison, other models such as EchoCLIP, |
| 2025 | EchoGPT proposed | MAE (Mean Absolute Error) | 7.5934 | Left Ventricular Ejection Fraction Prediction · split: test | EchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram VideosSource quoteL247: 50%, and above 70%. In terms of the R² score, EchoGPT reached 0.6848, implying that our model accounts for approximately 68.48% of the variability in ejection fraction, the highest proportion among all compared models. Furthermore, EchoGPT’s mean absolute error (MAE) was 7.5934, the lowest among all models, which further corroborates the high precision of EchoGPT in predicting left ventricular ejection fraction. In comparison, other models such as EchoCLIP, |