EchoNet-Dynamic · Image Generation
32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API
Tasks on EchoNet-DynamicAll tasks (32)Image Segmentation (11)Ejection Fraction Estimation (7)Ejection Fraction Regression (2)Image Generation (2)Video Generation (2)Binary Classification (1)Cardiac Function Estimation (1)Classification (1)
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Image Generation.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ADM-EDM with Discriminator Guidance (DG) SOTA frontier | 2.6 | 2023-11-01 | resolution=64×64 · NFE=59 · sampler=EDM · samples=50000 per epoch · DG-vector-scaling=2 · FID evaluated over 50,000 samples per epoch. A UNet-encoder discriminator was trained… | Exploring the Hyperparameter Space of Image Diffusion Models for Echocardiogram GenerationSource quoteOnce our discriminator is trained, we plug it in the reverse diffusion process as described in~\cite{kim2023refining}, and samples 50,000 for every epoch, in order to find the best performing one. We find that, for the best epoch with the nest set of hyperparameters, the FID improves from 3.75 to 2.60, showing the significance of DG. We use 30 (59 NFE) sampling steps, a weight of 5 for the first order EDM prediction, no guidance for the correction (weight 0) and a scaling of 2 for the Discriminator Guidance vectors. |
| 2 | MCDM (ReID+Flow) | 47.1 | 2025-12-01 | variant=ReID+Flow · video-length=64-frames · 64-frame synthetic videos; label-free, motion-conditioned MCDM using re-identificatio… | Label-free Motion-Conditioned Diffusion Model for Cardiac Ultrasound SynthesisSource quotemotion │ \(×\) │ MCDM (ReID+Flow) │ 47.1 │ 225.1 │ -- │ \textbf{2.19-± 0.06} |
TaskImage Segmentation (24)Ejection Fraction Estimation (13)Video Generation (6)Ejection Fraction Regression (5)Left Ventricular Ejection Fraction Prediction (5)Binary Classification (4)Video Segmentation (4)
Showing 2 of 2 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | MCDM (ReID+Flow) proposed | FID↓ | 47.1 | Image Generation · variant=ReID+Flow · video-length=64-frames | Label-free Motion-Conditioned Diffusion Model for Cardiac Ultrasound SynthesisSource quoteL134: motion │ \(×\) │ MCDM (ReID+Flow) │ 47.1 │ 225.1 │ -- │ \textbf{2.19-± 0.06} |
| 2023 | ADM-EDM with Discriminator Guidance (DG) proposed | FID | 2.60 | Image Generation · resolution=64×64 · NFE=59 · sampler=EDM · samples=50000 per epoch · DG-vector-scaling=2 | Exploring the Hyperparameter Space of Image Diffusion Models for Echocardiogram GenerationSource quoteL49: Once our discriminator is trained, we plug it in the reverse diffusion process as described in~\cite{kim2023refining}, and samples 50,000 for every epoch, in order to find the best performing one. We find that, for the best epoch with the nest set of hyperparameters, the FID improves from 3.75 to 2.60, showing the significance of DG. We use 30 (59 NFE) sampling steps, a weight of 5 for the first order EDM prediction, no guidance for the correction (weight 0) and a scaling of 2 for the Discriminator Guidance vectors. |