EchoNet-Dynamic

32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Ejection Fraction Estimation.

3.94.14.34.520222023EchoCoTr: 3.95 (2022)EchoGNN: 4.45 (2022)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025EchoGPT proposedR²0.6848Left Ventricular Ejection Fraction Prediction · split: testEchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram Videos
Source quote
L247: 50%, and above 70%. In terms of the R² score, EchoGPT reached 0.6848, implying that our model accounts for approximately 68.48% of the variability in ejection fraction, the highest proportion among all compared models. Furthermore, EchoGPT’s mean absolute error (MAE) was 7.5934, the lowest among all models, which further corroborates the high precision of EchoGPT in predicting left ventricular ejection fraction. In comparison, other models such as EchoCLIP,
2024CoReEcho proposedR282.44Image SegmentationCoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis
Source quote
L4: Deep learning (DL) models have been advancing automatic medical image analysis on various modalities, including echocardiography, by offering a comprehensive end-to-end training pipeline. This approach enables DL models to regress ejection fraction (EF) directly from 2D+time echocardiograms, resulting in superior performance. However, the end-to-end training pipeline makes the learned representations less explainable. The representations may also fail to capture the continuous relation among echocardiogram clips, indicating the existence of spurious correlations, which can negatively affect the generalization. To mitigate this issue, we propose \texttt{CoReEcho}{}, a novel training framework emphasizing continuous representations tailored for direct EF regression. Our extensive experiments demonstrate that \texttt{CoReEcho}{}: 1) outperforms the current state-of-the-art (SOTA) on the largest echocardiography dataset (EchoNet-Dynamic) with MAE of 3.90 \ │ R2 of 82.44, and 2) provides robust and generalizable features that transfer more effectively in related downstream tasks. The code is publicly available at \url{https://github.com/BioMedIA-MBZUAI/CoReEcho}.
2024EchoDiffusion (EchoDiff.) baselineR20.55Ejection Fraction RegressionEchoNet-Synthetic: Privacy-preserving Video Generation for Safe Medical Data Sharing
Source quote
L275: EchoDiff.~\cite{reynaud2023feature} │ 0.55 │ 6.02 │ 8.21
2022DTGN (D'ARTAGNAN) proposedR20.51Counterfactual Video Generation · selection=best of 100 sampled U_Y valuesD'ARTAGNAN: Counterfactual Video Generation
Source quote
L102: R2 │ 0.87 │ 0.51