EchoNet-Dynamic
32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API
Tasks on EchoNet-DynamicAll tasks (32)Image Segmentation (11)Ejection Fraction Estimation (7)Ejection Fraction Regression (2)Image Generation (2)Video Generation (2)Binary Classification (1)Cardiac Function Estimation (1)Classification (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Ejection Fraction Estimation.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | EchoCoTr SOTA frontier | 3.95 | 2022-01-01 | modality=echocardiography video · LVEF estimation on ultrasound videos; split and other evaluation conditions are not s… | EchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal EchocardiographySource quoteLearning spatiotemporal features is an important task for efficient video understanding especially in medical images such as echocardiograms. Convolutional neural networks (CNNs) and more recent vision transformers (ViTs) are the most commonly used methods with limitations per each. CNNs are good at capturing local context but fail to learn global information across video frames. On the other hand, vision transformers can incorporate global details and long sequences but are computationally expensive and typically require more data to train. In this paper, we propose a method that addresses the limitations we typically face when training on medical video data such as echocardiographic scans. The algorithm we propose (EchoCoTr) utilizes the strength of vision transformers and CNNs to tackle the problem of estimating the left ventricular ejection fraction (LVEF) on ultrasound videos. We demonstrate how the proposed method outperforms state-of-the-art work to-date on the EchoNet-Dynamic dataset with MAE of 3.95 and R^2 of 0.82. These results show noticeable improvement compared to all published research. In addition, we show extensive ablations and comparisons with several algorithms, including ViT and BERT. The code is available |
| 2 | EchoGNN | 4.45 | 2022-08-01 | EF prediction; Table 1. | EchoGNN: Explainable Ejection Fraction Estimation with Graph Neural NetworksSource quote0.76 4.45 |
Other primary task on EchoNet-Dynamic: Image Generation · FID ↓ (2 papers)
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ADM-EDM with Discriminator Guidance (DG) SOTA frontier | 2.6 | 2023-11-01 | resolution=64×64 · NFE=59 · sampler=EDM · samples=50000 per epoch · DG-vector-scaling=2 · FID evaluated over 50,000 samples per epoch. A UNet-encoder discriminator was trained… | Exploring the Hyperparameter Space of Image Diffusion Models for Echocardiogram GenerationSource quoteOnce our discriminator is trained, we plug it in the reverse diffusion process as described in~\cite{kim2023refining}, and samples 50,000 for every epoch, in order to find the best performing one. We find that, for the best epoch with the nest set of hyperparameters, the FID improves from 3.75 to 2.60, showing the significance of DG. We use 30 (59 NFE) sampling steps, a weight of 5 for the first order EDM prediction, no guidance for the correction (weight 0) and a scaling of 2 for the Discriminator Guidance vectors. |
| 2 | MCDM (ReID+Flow) | 47.1 | 2025-12-01 | variant=ReID+Flow · video-length=64-frames · 64-frame synthetic videos; label-free, motion-conditioned MCDM using re-identificatio… | Label-free Motion-Conditioned Diffusion Model for Cardiac Ultrasound SynthesisSource quotemotion │ \(×\) │ MCDM (ReID+Flow) │ 47.1 │ 225.1 │ -- │ \textbf{2.19-± 0.06} |
Other primary task on EchoNet-Dynamic: Image Segmentation · MAE ↓ · test (2 papers)
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MCSDR (vision-only) SOTA frontier | 3.76 | 2026-02-01 | Test set; evaluated in vision-only mode to avoid label leakage from derived text attr… | Generative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography VideoSource quoteDespite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89). |
| 2 | CoReEcho SOTA frontier | 3.9 | 2024-01-01 | EF regression; predictions from three sampled clips averaged for each video. | CoReEcho: Continuous Representation Learning for 2D+Time Echocardiography AnalysisSource quoteComparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.} |
Other primary task on EchoNet-Dynamic: Image Segmentation · mDice ↑ (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SAMUS SOTA frontier | 91.79 | 2024-01-01 | EchoNet-Dynamic videos have labels only for end-systolic and end-diastolic phases; ev… | MemSAM: Taming Segment Anything Model for Echocardiography Video SegmentationSource quote91.79 |
| 2 | EchoONE | 88.36 | 2025-01-01 | training=not used · evaluation=external · External evaluation; EchoNet-Dynamic was not used for training. | EchoONE: Segmenting Multiple Echocardiography Planes in One ModelSource quoteEchoONE │ 73.94 │ 59.31 │ 88.36 │ 79.65 |
TaskImage Segmentation (24)Ejection Fraction Estimation (13)Video Generation (6)Ejection Fraction Regression (5)Left Ventricular Ejection Fraction Prediction (5)Binary Classification (4)Video Segmentation (4)
Showing 3 of 3 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2023 | SimLVSeg-3D proposed | overall DSC | 93.32% | Video Segmentation · split: test · frames=32 | UniLVSeg: Unified Left Ventricular Segmentation with Sparsely Annotated Echocardiogram Videos through Self-Supervised Temporal Masking and Weakly Supervised TrainingSource quoteL123: \texttt{SimLVSeg}{} outperforms recent state-of-the-art approaches (\cite{ouyang2020video, Isensee2021-yh, weak_supervision}) on the EchoNet test set, as shown in Table \ref{tab_main} and Figure \ref{fig_comparisons}. We compare our method with the approach proposed by the EchoNet dataset publisher \cite{ouyang2020video}, the famous nnU-Net \cite{Isensee2021-yh}, which can perform better than specially designed echocardiography networks as mentioned in \cite{sarina_lightweight}, and the method achieving the highest dice similarity coefficient (DSC) on the test set \cite{weak_supervision}. \texttt{SimLVSeg}{} with 3D U-Net (\texttt{SimLVSeg}{}-3D) results in 93.32% overall DSC, and \texttt{SimLVSeg}{}-SI approach shows on-par performance. Confidence interval (CI) analysis further shows no overlap between the 95% CI of \texttt{SimLVSeg}{} with other state-of-the-art solutions, indicating that our improvements hold statistical significance over those methods with a p-value of less than 0.05. The \texttt{SimLVSeg}{}-3D was trained with 32 frames sampled consecutively, while the \texttt{SimLVSeg}{}-SI was trained with 16 frames sampled at every 5\textsuperscript{th} frame. This experiment shows that a video segmentation network trained in a weakly-supervised manner is capable of segmenting the LV with a 3.8x lower computational cost compared to \cite{weak_supervision}. |
| 2023 | SimLVSeg-SI with SSL temporal-masking pre-training proposed | overall DSC | 93.31% | Video Segmentation · variant=with SSL temporal-masking pre-training | UniLVSeg: Unified Left Ventricular Segmentation with Sparsely Annotated Echocardiogram Videos through Self-Supervised Temporal Masking and Weakly Supervised TrainingSource quoteL189: We observed that randomly masking a significant portion (60%) of an echocardiogram clip during SSL pre-training results in the best performance. The masking SSL improves the overall DSC of the SI approach from 93.19% to 93.31%, as reported in Figure \ref{fig_ssl}. Further, as shown in Fig. \ref{fig:discussion}, we observe that self-supervision with temporal masking enables the network to maintain better temporal consistency across predictions in a given echocardiogram clip. Fig. \ref{fig:discussion_segmentation} demonstrates that a video segmentation model pre-trained with self-supervised temporal masking is more resilient to noise and missing artifacts. The pre-training stage also alleviates the over-segmentation and temporal inconsistency issues that are commonly encountered in echocardiography caused by unclear (or, even worse, invisible) boundaries. Also, the SSL pre-trained model achieves a smoother LV segmentation area prediction with significantly less rapid fluctuations (see Fig. \ref{fig:discussion_lv_area}), indicating better temporal consistency. We further investigate the phenomenon in the frequency domain by applying the Fast Fourier Transform (FFT) to the predicted signals (LV area) as depicted in Fig. \ref{fig:discussion_freq_comp}. We observe that SSL pre-training results in a lower magnitude of the high-frequency components, which are typically the result of noise and rapid fluctuation. Based on these observations, we hypothesize that the pre-training stage helps the 3D U-Net model to better learn the semantic features that are useful for estimating human heart structures in the A4C view, resulting in a more robust prediction. Additionally, Table \ref{tab_ood} showcases the significant impact of the SSL pre-training stage when testing with samples subject to distribution shifts, indicating that the SSL pre-training enhances the model's generalization capability. These findings indicate that pre-training with self-supervision remarkably benefits the downstream LV segmentation task. Hence, self-supervised learning with vast echocardiogram videos can be a promising solution to provide strong pre-trained models that can generalize well in downstream echocardiography-related clinical tasks. |
| 2023 | SimLVSeg-SI with MobileNetV3 backbone proposed | overall DSC | 93.16% | Video Segmentation · backbone=MobileNetV3 · params=6.69M | UniLVSeg: Unified Left Ventricular Segmentation with Sparsely Annotated Echocardiogram Videos through Self-Supervised Temporal Masking and Weakly Supervised TrainingSource quoteL191: We have shown that both the SI and 3D segmentation networks trained using our proposed \texttt{SimLVSeg}{} are capable of accurately segmenting the left ventricle in echocardiogram videos. Both \texttt{SimLVSeg}{}-3D and \texttt{SimLVSeg}{}-SI outperform the state-of-the-art \cite{weak_supervision}, suggesting that the superior performance can be attributed to the \texttt{SimLVSeg}{} design rather than the selection of the underlying network architectures. The 3D U-Net performance is slightly better than the SI network with the UniFormer-S backbone. However, designing a backbone for 3D U-Net is not straightforward since it requires tedious hyperparameter tuning. On the other hand, there are plenty of optimized models that can be utilized as a backbone for the SI approach. For instance, MobileNetV3, with only 6.69 M of parameters, can give an on-par performance with 93.16% overall DSC, as seen in Table \ref{tab_backbones}. The pre-trained models on ImageNet can also help generalize better if we only have a small amount of data. Moreover, many self-supervised learning algorithms for 2D can also be explored to further improve \texttt{SimLVSeg}{} performance. |