EchoNet-Dynamic

32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Ejection Fraction Estimation.

3.94.14.34.520222023EchoCoTr: 3.95 (2022)EchoGNN: 4.45 (2022)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 10 of 10 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MCSDR (vision-only)MAE3.76Image Segmentation · split: testGenerative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video
Source quote
L191: Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89).
2026PanEcho baselineMAE5.35Image Segmentation · split: testGenerative Regression for Left Ventricular Ejection Fraction Estimation from Echocardiography Video
Source quote
L191: Despite utilizing only visual inputs, MCSDR establishes a new state-of-the-art, achieving an MAE of 3.76. Notably, it outperforms the recent foundation model PanEcho (MAE 5.35) and the latest multitask regression framework FHFA-MTL (MAE 3.89).
2025EchoGPT proposedMAE (Mean Absolute Error)7.5934Left Ventricular Ejection Fraction Prediction · split: testEchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram Videos
Source quote
L247: 50%, and above 70%. In terms of the R² score, EchoGPT reached 0.6848, implying that our model accounts for approximately 68.48% of the variability in ejection fraction, the highest proportion among all compared models. Furthermore, EchoGPT’s mean absolute error (MAE) was 7.5934, the lowest among all models, which further corroborates the high precision of EchoGPT in predicting left ventricular ejection fraction. In comparison, other models such as EchoCLIP,
2025VidFuncta only φ ablationMAE6.11Ejection Fraction Prediction · split: test · evaluation=5-foldVidFuncta: Towards Generalizable Neural Representations for Ultrasound Videos
Source quote
L160: VidFuncta only \phi │ 6.11 │ 8.35 │ 0.56 │ 62.5 │ 70.3 │ 65.6 │ 64.6 │ 68.1 │ 63.0
2025PocovidNet on 𝒱 baselineMAE4.34Ejection Fraction Prediction · split: test · input=original video · evaluation=5-foldVidFuncta: Towards Generalizable Neural Representations for Ultrasound Videos
Source quote
L169: PocovidNet on \mathcal{V} │ 4.34 │ 5.84 │ 0.77 │ 86.7 │ 88.2 │ 93.1 │ 76.1 │ 80.1 │ 82.3
2025PanEcho baselineLV EF MAE5.79Regression · split: test · 0-shotCardioBench: Do Echocardiography Foundation Models Generalize Beyond the Lab?
Source quote
L77: PanEcho \cite{holste2025panecho} {\textcolor{customblue}{\scalebox{0.6}{\ding{108}}}} │ 5.79 │ 11.63 │ 9.10 │ 0.36 │ 0.21 │ 0.18 │ 58.90 │ 30.50 │ 24.30 │ 20.52
2023SupReMix proposedMAE4.02%Cardiac Function Estimation · split: test · linear-probe · pretraining-epochs=200 · linear-probe-epochs=100SupReMix: Supervised contrastive learning for medical imaging regression with mixup
Source quote
L228: We compare SupReMix against both classification-based (SimCLR \citep{chen2019self}, SupCon \citep{khosla2020supervised}) and regression-based (AdaCon \citep{dai2021adaptive}, RnC \citep{zha2023rank}) representation learning methods across six medical imaging regression datasets spanning different modalities (MRI, X-ray, ultrasound, and PET). As shown in Figure \ref{fig:mae_comparision}, SupReMix consistently achieves lower MAE than all baseline methods. Taking bone age prediction on RSNA as an example, SupReMix reduces the MAE to 4.08 months compared to the classification-based method SupCon (6.79 months). The performance gains are particularly notable in challenging tasks such as cardiac function estimation, where SupReMix achieves an MAE of 4.02 compared to SupCon's 5.88. Moreover, we observe that SupReMix consistently outperforms vanilla regression (shown in dashed line). Additional performance metrics including Mean Squared Error (MSE), correlation coefficient (\rho), and Geometric Mean (GM) error are provided in Tables \ref{table1}, \ref{table2}, \ref{table3}, \ref{table4}, \ref{table5}, \ref{table6}.
2023GEMTrans proposedMAE4.15 mmEjection Fraction Estimation · split: test · video-setting=single-video A4C/AP4GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular Diagnosis
Source quote
L132: 4.15
2023SupCon baselineMAE5.88%Cardiac Function Estimation · split: test · linear-probe · pretraining-epochs=200 · linear-probe-epochs=100SupReMix: Supervised contrastive learning for medical imaging regression with mixup
Source quote
L228: We compare SupReMix against both classification-based (SimCLR \citep{chen2019self}, SupCon \citep{khosla2020supervised}) and regression-based (AdaCon \citep{dai2021adaptive}, RnC \citep{zha2023rank}) representation learning methods across six medical imaging regression datasets spanning different modalities (MRI, X-ray, ultrasound, and PET). As shown in Figure \ref{fig:mae_comparision}, SupReMix consistently achieves lower MAE than all baseline methods. Taking bone age prediction on RSNA as an example, SupReMix reduces the MAE to 4.08 months compared to the classification-based method SupCon (6.79 months). The performance gains are particularly notable in challenging tasks such as cardiac function estimation, where SupReMix achieves an MAE of 4.02 compared to SupCon's 5.88. Moreover, we observe that SupReMix consistently outperforms vanilla regression (shown in dashed line). Additional performance metrics including Mean Squared Error (MSE), correlation coefficient (\rho), and Geometric Mean (GM) error are provided in Tables \ref{table1}, \ref{table2}, \ref{table3}, \ref{table4}, \ref{table5}, \ref{table6}.
2023Thomas et al. [24] baselineMAE4.23 mmEjection Fraction Estimation · split: test · video-setting=single-video A4C/AP4GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular Diagnosis
Source quote
L122: 4.23