EchoNet-Dynamic

32 papers · 84 extracted observations · image segmentation · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Ejection Fraction Estimation.

3.94.14.34.520222023EchoCoTr: 3.95 (2022)EchoGNN: 4.45 (2022)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 10 of 10 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Single-parameter latent orbit features with supervised MLP prediction head proposedEF MAE6.02%Image SegmentationSelf-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits
Source quote
L143: We compare our approach with LMP~\cite{yangLatentMotionProfiling2026} by training an equivalent MLP head using the concatenation of its structure and motion features. Our method yields improved EF prediction performance (6.02% MAE vs.\ 6.27% MAE) with one-tenth as many pre-training epochs, indicating that the proposed cyclic prior provides a strong inductive bias for capturing motion cues relevant to cardiac function assessment. Fully supervised methods (e.g., \cite{maani2024coreecho}) act as an upper bound.
2025EchoGPT proposedMAE (Mean Absolute Error)7.5934Left Ventricular Ejection Fraction Prediction · split: testEchoGPT: An Interactive Cardiac Function Assessment Model for Echocardiogram Videos
Source quote
L247: 50%, and above 70%. In terms of the R² score, EchoGPT reached 0.6848, implying that our model accounts for approximately 68.48% of the variability in ejection fraction, the highest proportion among all compared models. Furthermore, EchoGPT’s mean absolute error (MAE) was 7.5934, the lowest among all models, which further corroborates the high precision of EchoGPT in predicting left ventricular ejection fraction. In comparison, other models such as EchoCLIP,
2024CoReEcho proposedMAE3.90Image SegmentationCoReEcho: Continuous Representation Learning for 2D+Time Echocardiography Analysis
Source quote
L189: Comparison with SOTA. In Table \ref{tab:echonet}, we compare \texttt{CoReEcho}{} with SOTA methods using the largest echocardiography dataset \cite{ouyang2020video}. While assessing both \texttt{CoReEcho}{} and EchoCoTr \cite{echocotr}, we average the EF predictions of three sampled clips for each video to reduce the randomness introduced by the clip sampling process. \texttt{CoReEcho}{} achieves the lowest MAE {of 3.90} and RMSE {of 5.13}, and the highest R2, indicating superiority over other methods. Additionally, \texttt{CoReEcho}{} is more efficient than \cite{ouyang2020video,hadrien_uvt,sarina_lightweight} since it provides a direct EF regression, thus removing the need for the segmentation stage to determine a heartbeat cycle. {The training time for \texttt{CoReEcho}{} is 4 hours, and the inference time is 5.95 ± 0.14 ms per clip, demonstrating our method's suitability for real-time processing.}
2023SupReMix proposedMAE4.02%Cardiac Function Estimation · split: test · linear-probe · pretraining-epochs=200 · linear-probe-epochs=100SupReMix: Supervised contrastive learning for medical imaging regression with mixup
Source quote
L228: We compare SupReMix against both classification-based (SimCLR \citep{chen2019self}, SupCon \citep{khosla2020supervised}) and regression-based (AdaCon \citep{dai2021adaptive}, RnC \citep{zha2023rank}) representation learning methods across six medical imaging regression datasets spanning different modalities (MRI, X-ray, ultrasound, and PET). As shown in Figure \ref{fig:mae_comparision}, SupReMix consistently achieves lower MAE than all baseline methods. Taking bone age prediction on RSNA as an example, SupReMix reduces the MAE to 4.08 months compared to the classification-based method SupCon (6.79 months). The performance gains are particularly notable in challenging tasks such as cardiac function estimation, where SupReMix achieves an MAE of 4.02 compared to SupCon's 5.88. Moreover, we observe that SupReMix consistently outperforms vanilla regression (shown in dashed line). Additional performance metrics including Mean Squared Error (MSE), correlation coefficient (\rho), and Geometric Mean (GM) error are provided in Tables \ref{table1}, \ref{table2}, \ref{table3}, \ref{table4}, \ref{table5}, \ref{table6}.
2023GEMTrans proposedMAE4.15 mmEjection Fraction Estimation · split: test · video-setting=single-video A4C/AP4GEMTrans: A General, Echocardiography-based, Multi-Level Transformer Framework for Cardiovascular Diagnosis
Source quote
L132: 4.15
2023UCVME proposedMAE4.37Ejection Fraction Estimation · semi-supervised · labeled-data=25%Semi-Supervised Deep Regression with Uncertainty Consistency and Variational Model Ensembling via Bayesian Neural Networks
Source quote
L441: Our method consistently achieves the best results for all settings by significant margins. We are also able to achieve an MAE of 4.37 using a quarter of the labels, which is only a relative 5.8% higher than the 4.13 MAE achieved by Ouyang et al. on fully labeled data. Our proposed method therefore reduces the number of labels required for training which is highly valuable for medical regression tasks.
2022EchoCoTr proposedMAE3.95Ejection Fraction Estimation · modality=echocardiography videoEchoCoTr: Estimation of the Left Ventricular Ejection Fraction from Spatiotemporal Echocardiography
Source quote
L4: Learning spatiotemporal features is an important task for efficient video understanding especially in medical images such as echocardiograms. Convolutional neural networks (CNNs) and more recent vision transformers (ViTs) are the most commonly used methods with limitations per each. CNNs are good at capturing local context but fail to learn global information across video frames. On the other hand, vision transformers can incorporate global details and long sequences but are computationally expensive and typically require more data to train. In this paper, we propose a method that addresses the limitations we typically face when training on medical video data such as echocardiographic scans. The algorithm we propose (EchoCoTr) utilizes the strength of vision transformers and CNNs to tackle the problem of estimating the left ventricular ejection fraction (LVEF) on ultrasound videos. We demonstrate how the proposed method outperforms state-of-the-art work to-date on the EchoNet-Dynamic dataset with MAE of 3.95 and R^2 of 0.82. These results show noticeable improvement compared to all published research. In addition, we show extensive ablations and comparisons with several algorithms, including ViT and BERT. The code is available
2022DTGN (D'ARTAGNAN) proposedMAE15.7%Counterfactual Ef Prediction · selection=best of 100 sampled U_Y valuesD'ARTAGNAN: Counterfactual Video Generation
Source quote
L103: MAE │ 2.79 │ 15.7
2022EchoGNN proposedMAE4.45Ejection Fraction EstimationEchoGNN: Explainable Ejection Fraction Estimation with Graph Neural Networks
Source quote
L142: 0.76 4.45
2021UVT (M., mirror video sampling) proposed non-standard sliceMAE5.95Ejection Fraction Estimation · video-sampling=mirrorUltrasound Video Transformers for Cardiac Ejection Fraction Estimation
Source quote
L114: M. (ours) │ 5.32 (4.90) │ 7.23 │ 0.64 │ 5.95 (5.90) │ 8.38 │ 0.52