CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 150 of 316 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard sliceAUROCf (failure-detection AUROC)0.487split: testCan saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L307: both models (0.487 and 0.536, with intervals including 0.5).
2026Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard sliceAUROCf (failure-detection AUROC)0.536split: test · backbone=ViT-B/16Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L307: both models (0.487 and 0.536, with intervals including 0.5).
2026MedGemma-27B (Ours; symbolic entailment filtered) proposedSoundness0.9599model=MedGemma-27B · params=27B · filtering=symbolic-entailmentToward Guarantees for Clinical Reasoning in Vision Language Models via Formal Verification
Source quote
L187: \texttt{MedGemma-27B} │ 0.9301 │ 0.9599 │ +0.0298 │ 0.8231 │ 0.8107 │ -0.0124 │ -0.0601 │ +0.0024
2026MedGemma-27B (Ours; symbolic entailment filtered) proposedCompleteness0.8107model=MedGemma-27B · params=27B · filtering=symbolic-entailmentToward Guarantees for Clinical Reasoning in Vision Language Models via Formal Verification
Source quote
L187: \texttt{MedGemma-27B} │ 0.9301 │ 0.9599 │ +0.0298 │ 0.8231 │ 0.8107 │ -0.0124 │ -0.0601 │ +0.0024
2026MedCLIP + GazeWorld proposedAccuracy59.420-shot · subset=5×200A World Model of Radiologist Reading for Medical Image Representation Learning
Source quote
L682: 58.13 │ 59.42 │ 56.85
2026VIVID-Med proposedmacro-AUC0.8588linear-probeVIVID-Med: LLM-Supervised Structured Pretraining for Deployable Medical ViTs
Source quote
L128: Table~\ref{tab:main_combined} summarizes performance on CheXpert and NIH. In-domain, VIVID-Med achieves an exceptional 0.8588 macro-AUC on CheXpert, outperforming BiomedCLIP by {+}6.65 points despite using 500× less pretraining data. Conversely, self-supervised baselines (MAE, DINOv3) show competitive F1s but substantially lower AUCs, highlighting their inability to capture clinical ranking structures without explicit semantic guidance.
2026MedRAX + CRC-Router (TTA) proposedMacro wrong-accept risk4.6%split: testCRC-Router: Risk-Constrained Routing for Medical Agentic AI Systems
Source quote
L186: Macro Risk │ 5.7% │ 4.8% │ 3.8% │ Macro Risk │ 20.9% │ 4.6%
2026Full (Graph-of-Differences) proposedR1↑ (Rank-1)0.33590-shot · evaluation=external-transferGraph-of-Differences: Anatomy-Structured Difference Alignment for Medical Image Re-Identification
Source quote
L232: 0.9033 │ 0.8294 │ 0.3359 │ 0.3926
2026Causal conditioning (sampling) proposedAUC of pleural effusion predictor82.33generation=sampling · conditioning=causalTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Causal conditioning (counterfactual generation) proposedAUC of pleural effusion predictor81.67generation=counterfactual · conditioning=causalTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Grad-CAM, DenseNet-121 baselinePointing-game hit rate0.575520 CheXpert findings with a radiologist localization benchmark; a hit is scored when t…Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L131: for 0.575 (0.529–0.619) of DenseNet-121 findings and
2026Grad-CAM, ViT-B/16 baselinePointing-game hit rate0.381backbone=ViT-B/16Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L132: 0.381 (0.336–0.425) of ViT-B/16 findings, against 0.888
2026Radiologists' most-representative-point localization baselinePointing-game hit rate0.888Radiologist reference performance on the 520 CheXpert findings with a localization benc…Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L132: 0.381 (0.336–0.425) of ViT-B/16 findings, against 0.888
2026UBAIA baselineEOM0.745Individual Subgroup: Race; fairness result in the overall comparison table, not the rac…Stride-Net: Fairness-Aware Disentangled Representation Learning for Chest X-Ray Diagnosis
Source quote
L208: 0.895 │ {0.943} │ 0.745
2026No Adapt. baselinemean AUROC76.0Main results table; seventh value in the target-domain block (aggregate).Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray Diagnosis
Source quote
L139: No Adapt. │ 56.6 │ 62.3 │ 67.4 │ 67.4 │ 64.1 │ 69.7 │ 64.6 │ 74.3 │ 71.7 │ 79.4 │ 80.8 │ 71.2 │ 78.3 │ 76.0
2026TENT baselinemean AUROC77.4split: test · test-time-adaptationLeveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray Diagnosis
Source quote
L141: TENT │ 50.1 │ 50.1 │ 53.5 │ 55.3 │ 52.0 │ 63.0 │ 54.0 │ 77.7 │ 76.5 │ 80.6 │ 83.2 │ 65.5 │ 81.1 │ 77.4
2026MedGemma-27B (VLM; unfiltered) baselineSoundness0.9301model=MedGemma-27B · params=27B · filtering=unfilteredToward Guarantees for Clinical Reasoning in Vision Language Models via Formal Verification
Source quote
L187: \texttt{MedGemma-27B} │ 0.9301 │ 0.9599 │ +0.0298 │ 0.8231 │ 0.8107 │ -0.0124 │ -0.0601 │ +0.0024
2026MedGemma-27B (VLM; unfiltered) baselineCompleteness0.8231model=MedGemma-27B · params=27B · filtering=unfilteredToward Guarantees for Clinical Reasoning in Vision Language Models via Formal Verification
Source quote
L187: \texttt{MedGemma-27B} │ 0.9301 │ 0.9599 │ +0.0298 │ 0.8231 │ 0.8107 │ -0.0124 │ -0.0601 │ +0.0024
2026OMIB (Wu et al., 2025) baselinemAUC89.3%split: test · subset=five diseasesIBMA: Information Bottleneck-Based Multimodal Alignment
Source quote
L479: 89.3
2026Baseline-WT baselineWG accuracy71.0method-setting=inverse-frequency sample weighting using predicted spurious-label groupsSpurCon: Weighted Supervised Contrastive Learning for Mitigating Spurious Cues in Medical Imaging
Source quote
L279: {71.0 }
2026Deterministic conditioning (sampling) baselineAUC of pleural effusion predictor80.65generation=sampling · conditioning=deterministicTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Undirected conditioning (sampling) baselineAUC of pleural effusion predictor82.15generation=sampling · conditioning=undirectedTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Deterministic conditioning (counterfactual generation) baselineAUC of pleural effusion predictor79.79generation=counterfactual · conditioning=deterministicTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Undirected conditioning (counterfactual generation) baselineAUC of pleural effusion predictor81.54generation=counterfactual · conditioning=undirectedTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2025HiMed-3B proposedRATE (RaTEScore)0.487params=3BBeyond N-grams: A Hierarchical Reward Learning Framework for Clinically-Aware Medical Report Generation
Source quote
L287: HiMed-3B (\S) │ 0.182 │ 0.077 │ 0.032 │ 0.017 │ 0.163 │ 0.048 │ 0.157 │ 0.219 │ 0.487
2025DLDM (disentangled latent diffusion model) proposedEffectiveness Accuracy88.7%split: test · intervention=do(A=black)AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual Analysis
Source quote
L558: DLDM │ 88.7 │ 91.8 │ 93.3
2025DLDM (disentangled latent diffusion model) proposedFID score21.79FID of generated counterfactual images on the CheXpert dataset.AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual Analysis
Source quote
L617: DLDM │ 21.79 │ 25.89
2025Autonomous distillation proposedAUC0.920-shotTurning Drift into Constraint: Robust Reasoning Alignment in Non-Stationary Multi-Stream Environments
Source quote
L271: CARZero │ 0.84 │ 0.81 │ 0.92 │ 0.80 {\color[HTML]{FF0000} Ours} │ {\color[HTML]{FF0000} 0.85} │ {\color[HTML]{FF0000} 0.83} │ {\color[HTML]{FF0000} 0.92} │ {\color[HTML]{FF0000} 0.81} }
2025Synthetic+Real mix model proposedAUROC0.730split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained · evaluation-view=PAImproving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic Data
Source quote
L139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733),
2025MedImageInsight zero-shot proposedAcc80.5%0-shot · prompt=ImpressionBeyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray Populations
Source quote
L101: Comparing the image embeddings to parts of the radiology reports revealed notable performance boosts for the adult datasets. MIMIC performed best using (5) Findings as prompt (Acc = 78.0%, MCC = 0.57). CheXpert performed slightly better using (6) Impression (Acc = 80.5%, MCC = 0.62).
2025MedImageInsight zero-shot proposedMCC0.620-shot · prompt=ImpressionBeyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray Populations
Source quote
L101: Comparing the image embeddings to parts of the radiology reports revealed notable performance boosts for the adult datasets. MIMIC performed best using (5) Findings as prompt (Acc = 78.0%, MCC = 0.57). CheXpert performed slightly better using (6) Impression (Acc = 80.5%, MCC = 0.62).
2025MedImageInsight zero-shot ensemble proposedAbsolute MCC difference across race subgroups10%0-shot · method=zero-shot ensemble · subgroup=raceBeyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray Populations
Source quote
L419: Figure 3 (right) illustrates the absolute MCC differences across the demographic subgroups, sex, age, and race, in the CheXpert dataset. All evaluated methods exhibited varying levels of bias, reflected in performance differences across subgroups. ZS ensembling demonstrated a notable bias reduction compared to linear probing across all variables. For linear probing, differences ranged from 10% for sex, 14% for race, and up to 24% for age. In contrast, the ZS ensemble method achieved considerably lower bias levels, with the highest observed difference of 10% for race, while bias for sex and age remained below 5%. Although the ZS performance method demonstrated improved fairness compared to linear probing, methods such as LORA and KNN exhibited even smaller differences across all variables.
2025Pragmatic listener (trained with pragmatic speaker, α=0.2) proposedListener accuracy98.72%claims=4 · classes=2 · speaker-gamma=0.4 · candidate-utterances=4 · explanations-per-input=8Aligning Explanations with Human Communication
Source quote
L121: CheXpert │ 2 │ 78.21% │ 4 │ 84.62% │ 98.72%
2025XFMamba-S (frontal and lateral; cross-fusion; CVSM and MVCM enabled) proposedAUROC0.9184views=frontal-and-lateral · epochs=100 · fusion=cross-fusion · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L130: 8 │ Frontal \ │ Lateral │ cross-fusion │ \usym{2713} │ \usym{2713} │ 0.9184
2025ALTA proposedAccuracy56.6%0-shot · subset=5×200 · resolution=224Efficient Medical Vision-Language Alignment Through Adapting Masked Vision Models
Source quote
L286: Our ALTA │ 224 │ 83.2 │ 77.9 │ 91.0 │ 56.6
2025ALTA (adapter training) proposedP@5, text-to-image retrieval64.5subset=8×200 · adapter=trained · patches=all retainedEfficient Medical Vision-Language Alignment Through Adapting Masked Vision Models
Source quote
L529: Adapter training │ 51.3 │ 47.1 │ \multicolumn{1}{c|}{38.7} │ 64.5 │ 65.8 │ \multicolumn{1}{c|}{53.0} │ 56.8 │ 55.4 │ 46.8
2025ALTA (adapter training) proposedP@5, image-to-text retrieval56.8subset=5×200 · adapter=trained · patches=all retainedEfficient Medical Vision-Language Alignment Through Adapting Masked Vision Models
Source quote
L529: Adapter training │ 51.3 │ 47.1 │ \multicolumn{1}{c|}{38.7} │ 64.5 │ 65.8 │ \multicolumn{1}{c|}{53.0} │ 56.8 │ 55.4 │ 46.8
2025ART-ASyn proposedAP0.8639Image-level anomaly detection.ART-ASyn: Anatomy-aware Realistic Texture-based Anomaly Synthesis Framework for Chest X-Rays
Source quote
L204: On the CheXpert dataset, ART-ASyn achieves an AP of 0.8639 and an AUC of 0.7125. It surpasses the second-best method in AP, UniAS, which achieves 0.7926, marking an improvement of 0.0713. While ART-ASyn achieves consistent gains on most metrics, its AUC on CheXpert is lower than AnatPaste's score of 0.7825. This discrepancy may be attributed to the base model architecture, as further discussed in the ablation study.
2025EWC-Guided Diffusion Replay (DDPM+EWC) proposedAUROC0.851split: valEWC-Guided Diffusion Replay for Exemplar-Free Continual Learning in Medical Imaging
Source quote
L4: Medical imaging foundation models must adapt over time, yet full retraining is often blocked by privacy constraints and cost. We present a continual learning framework that avoids storing patient exemplars by pairing class conditional diffusion replay with Elastic Weight Consolidation. Using a compact Vision Transformer backbone, we evaluate across eight MedMNIST v2 tasks and CheXpert. On CheXpert our approach attains 0.851 AUROC, reduces forgetting by more than 30% relative to DER\texttt{++}, and approaches joint training at 0.869 AUROC, while remaining efficient and privacy preserving. Analyses connect forgetting to two measurable factors: fidelity of replay and Fisher weighted parameter drift, highlighting the complementary roles of replay diffusion and synaptic stability. The results indicate a practical route for scalable, privacy aware continual adaptation of clinical imaging models.
2025Stable Diffusion proposedclassification accuracy95%retained-coverage=55% · uncertainty-filtered=45% of most uncertain samples removedConditional Diffusion Models are Medical Image Classifiers that Provide Explainability and Uncertainty for Free
Source quote
L16: In this work, we present a comprehensive evaluation of how conditional diffusion models can be re-purposed and leveraged for image classification, explainability, and uncertainty estimation in the medical domain. First, we propose a novel majority voting-based method that improves the performance of diffusion classifiers in medical imaging. We then demonstrate that classifiers derived from foundation and trained-from-scratch diffusion models perform competitively with state-of-the-art medical image discriminative classifiers through extensive experiments on the publicly available CheXpert~\cite{irvin2019chexpert} and ISIC Melanoma skin cancer~\cite{Rotemberg2020APD} datasets, despite not being trained for classification. Next, we show that diffusion classifiers offer explainability (via counterfactual generation) and uncertainty quantification (via entropy) out-of-the-box. We validate the uncertainty by showing that when the model is confident, it is correct, and vice versa. This is shown as model accuracy drastically improves as its uncertainty threshold increases. For example, Stable Diffusion reaches classification accuracies of 100% and 95% on ISIC and CheXpert, respectively, with only 45% of its most uncertain samples filtered out.
2025MV-HFMD proposedAUC-ROC0.775label-setting=average across five uncertain-label scenarios and 13 classification tasksMCD-CLIP: Multi-view Chest Disease Diagnosis with Disentangled CLIP
Source quote
L393: 0.775
2025MV-HFMD proposedTunable Param36.05 MNumber of tunable parameters reported for the method on CheXpert; not an averaged task …MCD-CLIP: Multi-view Chest Disease Diagnosis with Disentangled CLIP
Source quote
L392: 36.05
2025RR-ClArC (ResNet50) proposedAccuracy (biased)0.79split: test · artifact=brightness · backbone=ResNet-50Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated data
Source quote
L1119: RR-ClArC │ {0.86} \,|\, {0.97} \,|\, {0.82} │ 0.76 \,|\, 0.96 \,|\, 0.79 │ 0.42 \,|\, {0.34} \,|\, - │ 0.00 \,|\, 0.07 \,|\, 0.00
2025U-Net + Text Encoder fine-tuning proposedAccuracy94.8%split: test · subset=No Finding · resolution=512×512Pixels Under Pressure: Exploring Fine-Tuning Paradigms for Foundation Models in High-Resolution Medical Imaging
Source quote
L156: When evaluated on real test images after training on synthetic data (Table~\ref{tab:model_accuracy}), models fine-tuned on both U-Net and Text Encoder achieve the highest accuracy across nearly all disease categories (e.g., 77.9% for Cardiomegaly, 94.8% for No Finding), highlighting strong generalization. BitFit also performs surprisingly well in this evaluation, suggesting that while it may underperform in generation quality, its generated images still retain enough semantic structure to be informative for downstream classification. LoRA and DoRA also demonstrate robust cross-domain transfer, particularly in high-signal classes such as Pneumothorax and No Finding, underscoring their utility as efficient yet effective fine-tuning alternatives.
2025CLIP fine-tuned with Palm2-bison fine-grained captions proposedaverage per-class accuracy (Avg)72.5%0-shot · backbone=CLIP · caption-source=Palm2-bison · caption-granularity=fineEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L116: Palm2-bison~\cite{anil2023palm} │ fine │ 74.6 │ 70.7 │ 72.4 │ 77.6 │ 56.9 │ 84.5 │ 70.3 │ 80.2 │ 93.1 │ 37.1 │ 79.7 │ 72.5
2025CLIP fine-tuned with Zephyr-7b coarse-grained captions proposedaverage per-class accuracy (Avg)53.2%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=coarseEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L127: coarse │ 65.9 │ 41.8 │ 78.9 │ 56.9 │ 42.7 │ 85.8 │ 49.1 │ 71.6 │ 85.8 │ 3.4 │ 3.4 │ 53.2
2025CLIP fine-tuned with Zephyr-7b medium-grained captions proposedaverage per-class accuracy (Avg)56.8%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=mediumEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L126: medium │ 66.4 │ 40.5 │ 82.8 │ 81.5 │ 48.7 │ 85.3 │ 46.1 │ 71.6 │ 85.3 │ 3.9 │ 12.9 │ 56.8
2025CLIP fine-tuned with Zephyr-7b fine-grained captions proposedaverage per-class accuracy (Avg)64.1%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=fineEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L125: \multirow[t]{3}{*}{zephyr-7b~\cite{tunstall2023zephyr}} │ fine │ 67.7 │ 43.1 │ 60.3 │ 60.3 │ 56.5 │ 83.2 │ 78.4 │ 79.3 │ 86.2 │ 62.5 │ 28.0 │ 64.1
2025Diff3M (Ours_demo) proposedAUPRC0.931split: test · variant=Ours_demo · sampling=600-step DDIM · demographics=usedHarnessing EHRs for Diffusion-Based Anomaly Detection on Chest X-Rays
Source quote
L181: AUPRC │ 0.888 │ 0.719 │ 0.889 │ 0.917 │ 0.931
2025AdvSimplex (Medical CLIP, CheXzero paradigm, ViT-B) proposed non-standard slicePGD AUC0.7350-shot · attack=PGD-20 · epsilon=1/255 · backbone=ViT-BImproving Zero-Shot Adversarial Robustness in Vision-Language Models by Closed-form Alignment of Adversarial Path Simplices
Source quote
L1165: 0.735
2025Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposedCFRT (Classifier Flip Rate along a Trajectory)0.78fine-tuned · trajectory=style · target-attribute=Pleural EffusionLanguage-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image Generation
Source quote
L101: \multicolumn{1}{c|}{\multirow{2}{*}{CFRT\uparrow}} │ \multirow{2}{*}{0.78} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.89}} │ MEL │ 0.91 │ 0.99 │ 0.59 │ 0.74
2025Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposedCFRT (Classifier Flip Rate along a Trajectory)0.89fine-tuned · trajectory=style · target-attribute=Support DevicesLanguage-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image Generation
Source quote
L101: \multicolumn{1}{c|}{\multirow{2}{*}{CFRT\uparrow}} │ \multirow{2}{*}{0.78} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.89}} │ MEL │ 0.91 │ 0.99 │ 0.59 │ 0.74
2025Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposedLPIPS0.24fine-tuned · trajectory=style · target-attribute=Pleural EffusionLanguage-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image Generation
Source quote
L103: \multicolumn{1}{c|}{\multirow{2}{*}{LPIPS\downarrow}} │ \multirow{2}{*}{0.24} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.05}} │ MEL │ 0.08 │ 0.09 │ 0.12 │ 0.11
2025SiP, cross-center reference selection (CC) proposedBAcc.68.43finding=pneumonia · reference-source=MIMIC-CXR · reference-selection=cross-centerSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64
2025SiP, cross-center reference selection (CC) proposedF167.15finding=pneumonia · reference-source=MIMIC-CXR · reference-selection=cross-centerSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64
2025SiP, cross-center reference selection (CC) proposedBAcc.77.90finding=edema · reference-source=MIMIC-CXR · reference-selection=cross-centerSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64
2025SiP, cross-center reference selection (CC) proposedF179.04finding=edema · reference-source=MIMIC-CXR · reference-selection=cross-centerSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64
2025SiP, random reference selection (RS) proposedBAcc.68.70finding=pneumonia · reference-selection=randomSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L295: RS │ 68.70 │ 67.05 │ \multicolumn{1}{c}{---} │ \multicolumn{1}{c}{---}
2025SiP, random reference selection (RS) proposedBAcc.78.04finding=edema · reference-selection=randomSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L296: 78.04 │ 79.10 │ \multicolumn{1}{c}{---} │ \multicolumn{1}{c}{---}
2025AGA proposedPrec@550.28subset=5×200AGA: An adaptive group alignment framework for structured medical cross-modal representation learning
Source quote
L237: AGA │ 50.28 │ 49.84 │ 43.80
2025AGA proposedAUC56.10linear-probe · labeled-data=1%AGA: An adaptive group alignment framework for structured medical cross-modal representation learning
Source quote
L274: AGA │ 56.10 │ 61.31 │ 84.32 │ 68.91 │ 75.78 │ 87.92
2025Literal listener (trained with literal speaker, α=0.0) ablationListener accuracy84.62%claims=4 · classes=2 · speaker-gamma=0.4 · candidate-utterances=4 · explanations-per-input=8Aligning Explanations with Human Communication
Source quote
L121: CheXpert │ 2 │ 78.21% │ 4 │ 84.62% │ 98.72%
2025XFMamba-S (frontal and lateral; early fusion) ablationAUROC0.9090views=frontal-and-lateral · epochs=100 · fusion=early-fusion · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L125: 3 │ Frontal \ │ Lateral │ early-fusion │ \usym{2717} │ \usym{2717} │ 0.9090
2025XFMamba-S (frontal and lateral; late fusion) ablationAUROC0.9092views=frontal-and-lateral · epochs=100 · fusion=late-fusion · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L126: 4 │ Frontal \ │ Lateral │ late-fusion │ \usym{2717} │ \usym{2717} │ 0.9092
2025XFMamba-S (lateral view only; no fusion) ablationAUROC0.8961views=lateral-only · epochs=100 · fusion=none · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L123: 1 │ Lateral │ no │ \usym{2717} │ \usym{2717} │ 0.8961
2025XFMamba-S (frontal view only; no fusion) ablationAUROC0.9081views=frontal-only · epochs=100 · fusion=none · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L124: 2 │ Frontal │ no │ \usym{2717} │ \usym{2717} │ 0.9081
2025Backbone score correlation (ordinary vs. soft metrics)R² of Pearson correlation between ordinary and soft AUROC scores0.465label=Pneumothorax · comparison=ordinary-versus-soft AUROC across backbonesClinical Uncertainty Impacts Machine Learning Evaluations
Source quote
L169: The analysis of the coefficients of determination R^2 in Figure~\ref{fig:DatasetAnalysis} shows that \gls*{ap} often decouples rankings between ordinary and soft settings moderately, and \gls*{auroc} can sometimes decouple them sharply (e.g., CheXpert--Pneumothorax AUROC R (2)\!=\!0.465 vs.\ AP R (2)\!=\!0.983).
2025Backbone score correlation (ordinary vs. soft metrics)R² of Pearson correlation between ordinary and soft AP scores0.983label=Pneumothorax · comparison=ordinary-versus-soft AP across backbonesClinical Uncertainty Impacts Machine Learning Evaluations
Source quote
L169: The analysis of the coefficients of determination R^2 in Figure~\ref{fig:DatasetAnalysis} shows that \gls*{ap} often decouples rankings between ordinary and soft settings moderately, and \gls*{auroc} can sometimes decouple them sharply (e.g., CheXpert--Pneumothorax AUROC R (2)\!=\!0.465 vs.\ AP R (2)\!=\!0.983).
2025MVMAEBrier score0.0904linear-probeStructure is Supervision: Multiview Masked Autoencoders for Radiology
Source quote
L305: MVMAE (ours) │ 0.0832 │ 0.0904 │ 0.0660 │ 0.0759
2025IndependentBrier score0.0920linear-probeStructure is Supervision: Multiview Masked Autoencoders for Radiology
Source quote
L302: Independent │ 0.0841 │ 0.0920 │ 0.0670 │ 0.0769
2025Joint trainingAUROC0.869Macro-averaged across five standard diagnosis labels; 95% CIs across 5 independent runs…EWC-Guided Diffusion Replay for Exemplar-Free Continual Learning in Medical Imaging
Source quote
L4: Medical imaging foundation models must adapt over time, yet full retraining is often blocked by privacy constraints and cost. We present a continual learning framework that avoids storing patient exemplars by pairing class conditional diffusion replay with Elastic Weight Consolidation. Using a compact Vision Transformer backbone, we evaluate across eight MedMNIST v2 tasks and CheXpert. On CheXpert our approach attains 0.851 AUROC, reduces forgetting by more than 30% relative to DER\texttt{++}, and approaches joint training at 0.869 AUROC, while remaining efficient and privacy preserving. Analyses connect forgetting to two measurable factors: fidelity of replay and Fisher weighted parameter drift, highlighting the complementary roles of replay diffusion and synaptic stability. The results indicate a practical route for scalable, privacy aware continual adaptation of clinical imaging models.
2025MedGemma-27B baselineRATE (RaTEScore)0.471params=27BBeyond N-grams: A Hierarchical Reward Learning Framework for Clinically-Aware Medical Report Generation
Source quote
L276: MedGemma-27B (*) │ 0.117 │ 0.047 │ 0.018 │ 0.006 │ 0.165 │ 0.033 │ 0.153 │ 0.183 │ 0.471
2025CLDM (standard conditional latent diffusion model) baselineEffectiveness Accuracy83.5%split: test · intervention=do(A=black)AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual Analysis
Source quote
L557: CLDM │ 83.5 │ 87.2 │ 89.1
2025CLDM (standard conditional latent diffusion model) baselineFID score22.14FID of generated counterfactual images on the CheXpert dataset.AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual Analysis
Source quote
L616: CLDM │ 22.14 │ 26.10
2025Real-only baseline baselineAUROC0.700split: test · training-data=66k real MIMIC-CXR images · initialization=ImageNet-pretrained · evaluation-view=PAImproving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic Data
Source quote
L139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733),
2025EfficientNet-b0 baselineAUROC0.752label=Cardiomegaly · backbone=EfficientNet-b0 · metric-setting=ordinaryClinical Uncertainty Impacts Machine Learning Evaluations
Source quote
L358: EfficientNet-b0 │ 0.752 │ 0.531 │ 0.683 │ 0.480
2025VGG-16 baselines-AUROC0.694label=Cardiomegaly · backbone=VGG-16 · metric-setting=softClinical Uncertainty Impacts Machine Learning Evaluations
Source quote
L360: VGG-16 │ 0.717 │ 0.493 │ 0.694 │ 0.491
2025GLoRIA baselineAverage accuracy50.00%split: test · fine-tuned · tasks=Consolidation; Pleural Effusion · image-view=frontalEnhancing Biomedical Multi-modal Representation Learning with Multi-scale Pre-training and Perturbed Report Discrimination
Source quote
L142: GLoRIA \cite{huang2021gloria} │ 71.11% │ 28.89% │ 50.00%
2025UniAS baselineAP0.7926Image-level anomaly detection; identified as the second-best method in AP.ART-ASyn: Anatomy-aware Realistic Texture-based Anomaly Synthesis Framework for Chest X-Rays
Source quote
L204: On the CheXpert dataset, ART-ASyn achieves an AP of 0.8639 and an AUC of 0.7125. It surpasses the second-best method in AP, UniAS, which achieves 0.7926, marking an improvement of 0.0713. While ART-ASyn achieves consistent gains on most metrics, its AUC on CheXpert is lower than AnatPaste's score of 0.7825. This discrepancy may be attributed to the base model architecture, as further discussed in the ablation study.
2025AIMv2 ViT-H baselineROC-AUC0.819fine-tuned · model=AIMv2 · backbone=ViT-HAdvancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation Models
Source quote
L145: ViT-H │ 0.731 │ 0.807 │ 0.819 │ 0.815
2025DINOv2 ViT-L baselineROC-AUC0.814fine-tuned · model=DINOv2 · backbone=ViT-LAdvancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation Models
Source quote
L134: ViT-L │ 0.731 │ 0.801 │ 0.814 │ 0.813
2025AIMv2 ViT-H baselineROC-AUC0.731linear-probe · model=AIMv2 · backbone=ViT-HAdvancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation Models
Source quote
L145: ViT-H │ 0.731 │ 0.807 │ 0.819 │ 0.815
2025DualNet baselineAUC-ROC0.738label-setting=average across five uncertain-label scenarios and 13 classification tasksMCD-CLIP: Multi-view Chest Disease Diagnosis with Disentangled CLIP
Source quote
L384: 0.738
2025Vanilla (ResNet50) baselineAccuracy (biased)0.44split: test · artifact=brightness · backbone=ResNet-50Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated data
Source quote
L1115: Vanilla │ {0.87} \,|\, {0.97} \,|\, {0.81} │ {0.28} \,|\, {0.62} \,|\, {0.44} │ {0.55} \,|\, {0.51} \,|\, - │ {0.17} \,|\, {0.30} \,|\, {0.33}
2025CLIP fine-tuned using Human Expert captions baselineaverage per-class accuracy (Avg)49.9%0-shot · backbone=CLIP · caption-source=Human ExpertEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L115: Human Expert~\cite{johnson2019mimiccxrjpg} │ 34.5 │ 29.3 │ 64.2 │ 54.7 │ 54.3 │ 56.0 │ 66.8 │ 65.9 │ 44.8 │ 39.7 │ 39.2 │ 49.9
2025Baseline (ResNet50) baselineWorst-group accuracy (WGAcc)25.87%split: test · folds=4 held-out · backbone=ResNet50 · evaluation=test-time attenuationLocalising Shortcut Learning in Pixel Space via Ordinal Scoring Correlations for Attribution Representations (OSCAR)
Source quote
L590: ResNet50 │ CheXpert │ Baseline │ 65.61 │ 25.87
2025DiAD baselineAUPRC0.917split: testHarnessing EHRs for Diffusion-Based Anomaly Detection on Chest X-Rays
Source quote
L181: AUPRC │ 0.888 │ 0.719 │ 0.889 │ 0.917 │ 0.931
2025ODP-Bench prediction algorithms (10-algorithm Avg.) baselineSpearman’s rank correlation (ρ)-0.248aggregation=10-algorithm average · target_group=ill femalesODP-Bench: Benchmarking Out-of-Distribution Performance Prediction
Source quote
L194: Dataset │ ATC │ Nu. Norm │ DOC │ NI │ MaNo │ Dispersion │ MDE │ Agreement │ COT │ COTT │ Avg. │ \#Effective CIFAR-10-C │ 0.951 │ 0.934 │ 0.884 │ 0.818 │ 0.836 │ 0.903 │ -0.832 │ 0.991 │ 0.980 │ 0.990 │ 0.746 │ 9 CIFAR-100-C │ 0.948 │ 0.829 │ 0.874 │ 0.868 │ 0.738 │ 0.718 │ -0.703 │ 0.971 │ 0.892 │ 0.985 │ 0.712 │ 9 NICO++ │ 0.970 │ 0.797 │ 0.742 │ 0.929 │ 0.846 │ 0.802 │ -0.777 │ 0.932 │ 0.844 │ 0.965 │ 0.705 │ 9 OfficeHome │ 0.911 │ 0.594 │ 0.465 │ 0.912 │ 0.754 │ 0.541 │ -0.409 │ 0.936 │ 0.693 │ 0.933 │ 0.633 │ 5 ObjectNet │ 0.794 │ 0.674 │ 0.640 │ 0.875 │ 0.672 │ 0.689 │ -0.670 │ 0.973 │ 0.706 │ 0.845 │ 0.620 │ 5 ImageNet-C │ 0.933 │ 0.596 │ 0.556 │ 0.790 │ 0.453 │ 0.581 │ -0.506 │ 0.933 │ 0.583 │ 0.839 │ 0.576 │ 4 ImageNet-V2 │ 0.993 │ 0.260 │ 0.958 │ 0.845 │ 0.149 │ 0.323 │ -0.216 │ 0.996 │ 0.357 │ 0.986 │ 0.565 │ 5 ImageNet-S │ 0.961 │ 0.500 │ 0.480 │ 0.846 │ 0.343 │ 0.438 │ -0.384 │ 0.838 │ 0.582 │ 0.987 │ 0.559 │ 4 PACS │ 0.708 │ 0.769 │ 0.657 │ 0.825 │ 0.489 │ 0.772 │ -0.736 │ 0.909 │ 0.498 │ 0.636 │ 0.553 │ 5 CIFAR-10.1 │ 0.717 │ 0.526 │ 0.423 │ 0.766 │ 0.524 │ 0.533 │ -0.524 │ 0.850 │ 0.556 │ 0.718 │ 0.509 │ 4 CIFAR-10.2 │ 0.780 │ 0.511 │ 0.364 │ 0.800 │ 0.511 │ 0.511 │ -0.508 │ 0.807 │ 0.541 │ 0.750 │ 0.507 │ 4 ImageNet-R │ 0.742 │ 0.325 │ 0.338 │ 0.859 │ 0.414 │ 0.232 │ -0.278 │ 0.926 │ 0.404 │ 0.885 │ 0.485 │ 4 TinyImageNet-C │ 0.617 │ 0.553 │ 0.454 │ 0.530 │ 0.487 │ 0.274 │ -0.343 │ 0.740 │ 0.583 │ 0.839 │ 0.473 │ 2 DomainNet │ 0.841 │ 0.563 │ 0.344 │ 0.235 │ 0.624 │ 0.563 │ -0.565 │ 0.433 │ 0.601 │ 0.874 │ 0.451 │ 2 STL-10 │ 0.718 │ 0.432 │ 0.003 │ 0.825 │ 0.412 │ 0.419 │ -0.402 │ 0.771 │ 0.567 │ 0.745 │ 0.449 │ 4 FMoW │ 0.964 │ 0.716 │ 0.172 │ 0.299 │ -0.305 │ 0.678 │ -0.674 │ 0.859 │ 0.681 │ 0.955 │ 0.435 │ 4 CINIC-10 │ 0.706 │ 0.318 │ -0.075 │ 0.867 │ 0.320 │ 0.307 │ -0.301 │ 0.794 │ 0.423 │ 0.728 │ 0.409 │ 4 VLCS │ 0.472 │ -0.036 │ 0.142 │ 0.699 │ 0.520 │ 0.145 │ 0.060 │ 0.777 │ 0.112 │ 0.457 │ 0.335 │ 1 iWildCam │ 0.669 │ 0.103 │ 0.341 │ 0.540 │ 0.023 │ 0.273 │ 0.012 │ 0.508 │ 0.190 │ 0.618 │ 0.328 │ 0 ImageNet-Vid │ -0.095 │ 0.712 │ -0.690 │ 0.556 │ 0.606 │ 0.648 │ -0.597 │ 0.654 │ 0.743 │ 0.737 │ 0.328 │ 3 RxRx1 │ 0.983 │ 0.882 │ -0.738 │ -0.538 │ -0.356 │ 0.863 │ -0.888 │ 0.979 │ 0.885 │ 0.979 │ 0.305 │ 6 ImageNet-A │ 0.503 │ 0.135 │ 0.208 │ 0.818 │ 0.209 │ 0.143 │ -0.158 │ 0.197 │ 0.122 │ 0.530 │ 0.270 │ 1 Amazon │ 0.749 │ 0.077 │ -0.225 │ 0.091 │ 0.073 │ -0.131 │ 0.810 │ 0.123 │ 0.640 │ 0.245 │ 3 Camelyon17 │ 0.296 │ 0.632 │ -0.506 │ -0.513 │ 0.056 │ 0.747 │ 0.315 │ -0.637 │ 0.796 │ 0.668 │ 0.185 │ 2 TerraInc │ 0.370 │ 0.440 │ 0.282 │ 0.355 │ -0.067 │ 0.438 │ -0.482 │ 0.422 │ -0.122 │ -0.062 │ 0.157 │ 0 CivilComments │ 0.806 │ -0.779 │ -0.096 │ 0.454 │ -0.850 │ 0.496 │ 0.818 │ -0.350 │ 0.537 │ 0.115 │ 3 Waterbirds │ 0.219 │ 0.449 │ 0.825 │ -0.194 │ 0.149 │ 0.475 │ 0.037 │ 0.473 │ -0.960 │ -0.883 │ 0.059 │ 1 CelebA │ 0.392 │ 0.498 │ 0.369 │ 0.027 │ 0.463 │ 0.602 │ -0.350 │ 0.162 │ -0.922 │ -0.825 │ 0.042 │ 0 CheXpert │ 0.052 │ 0.327 │ -0.752 │ -0.786 │ -0.472 │ 0.782 │ 0.535 │ -0.530 │ -0.786 │ -0.853 │ -0.248 │ 1
2025MGCA baselinePrec@549.54subset=5×200AGA: An adaptive group alignment framework for structured medical cross-modal representation learning
Source quote
L235: MGCA\cite{7} │ 49.54 │ 49.10 │ 42.25
2025MGCA baselineAUC55.21linear-probe · labeled-data=1%AGA: An adaptive group alignment framework for structured medical cross-modal representation learning
Source quote
L272: MGCA\cite{7} │ 55.21 │ 59.21 │ 83.92 │ 67.28 │ 76.12 │ 87.76
2024HybridMED proposedAcc0.4480-shot · subset=5×200 · pretraining-dataset=MIMIC-CXRAdvancing Medical Radiograph Representation Learning: A Hybrid Pre-training Paradigm with Multilevel Semantic Granularity
Source quote
L201: Ours │ MIMIC-CXR │ 0.800 │ 0.448
2024FactMM-RAG proposedF1CheXbert0.491retrieval-setting=multimodalFact-Aware Multimodal Retrieval Augmentation for Accurate Medical Radiology Report Generation
Source quote
L269: FactMM-RAG │ 0.605 │ 0.249 │ 0.297 │ 0.547 │ 0.491 │ 0.174 │ 0.237 │ 0.467
2024FactMM-RAG proposedF1RadGraph0.174retrieval-setting=multimodalFact-Aware Multimodal Retrieval Augmentation for Accurate Medical Radiology Report Generation
Source quote
L269: FactMM-RAG │ 0.605 │ 0.249 │ 0.297 │ 0.547 │ 0.491 │ 0.174 │ 0.237 │ 0.467
2024MGCA with 2x synthetic augmentation using single-disease prompts proposed non-standard slicemean F1 score0.289split: test · 1-shot · prompt=single-disease · backbone=MGCA · training-data=1% ground-truth · synthetic-augmentation=2xEvaluating and Improving the Effectiveness of Synthetic Chest X-Rays for Medical Image Analysis
Source quote
L34: In multilabel classification on CheXpert dataset, we also found it was most effective to generate the synthetic data using single-disease prompts (e.g. "cardiomegaly"), and the synthetic data was used to balance all classes to the count of the most frequent disease class. At 1% ground truth data, the mean F1 score increased from 0.209 with real data to 0.289 with 2x synthetic data. At 10% ground truth data, the F1 score improved from 0.255 to 0.323 with 2x synthetic data. At 100% ground truth data, synthetic data provided marginal improvements, with the F1 score increasing from 0.310 to 0.354 with balanced 2x synthetic augmentation (Figure \ref{fig:results}, Plot 4). These results demonstrate that the strategic addition of synthetic data can address class imbalance and significantly improve multilabel classification performance, especially in low-resource scenarios.
2024GCD g-direction proposedFR(\uparrow)91.1%split: val · directions-per-disease=1Global Counterfactual Directions
Source quote
L183: Pleural effusion │ \makecell{0.7863} │ \makecell{0.4126} │ \makecell{91.1}
2024GCD g-direction proposedFR(\uparrow)91.4%split: val · directions-per-disease=1Global Counterfactual Directions
Source quote
L184: Lung opacity │ \makecell{0.8430} │ \makecell{0.2171} │ \makecell{91.4}
2024GCD g-direction proposedFR(\uparrow)89.4%split: val · directions-per-disease=1Global Counterfactual Directions
Source quote
L185: Support devices │ \makecell{0.8247} │ \makecell{0.2321} │ \makecell{89.4}
2024LLaVA-Med (PT2) proposedF123.2split: test · prompt=PT2 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L242: F1 │ 23.2 │ 42.6
2024LLaVA-Med (PT3) proposedF142.6split: test · prompt=PT3 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L242: F1 │ 23.2 │ 42.6
2024LLaVA-Med (PT2) proposedfalse positive count410 countsplit: test · prompt=PT2 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L263: Edema │ 410 │ 88
2024LLaVA-Med (PT3) proposedfalse positive count88 countsplit: test · prompt=PT3 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L263: Edema │ 410 │ 88
2024EGMA proposedAcc.60.500-shot · subset=5x200Eye-gaze Guided Multi-modal Alignment for Medical Representation Learning
Source quote
L293: EGMA(Ours) │ 60.50 │ 58.44 │ 57.81 │ {36.70} │ 63.62 │ 61.46
2024EGMA proposedF158.440-shot · subset=5x200Eye-gaze Guided Multi-modal Alignment for Medical Representation Learning
Source quote
L293: EGMA(Ours) │ 60.50 │ 58.44 │ 57.81 │ {36.70} │ 63.62 │ 61.46
2024Attri-Net (unguided) proposedConfounder sensitivity0.747split: test · unguided · subset=synthetic shortcut test images · contamination=50% of cardiomegaly-positive samplesAttri-Net: A Globally and Locally Inherently Interpretable Model for Multi-Label Classification Using Class-Specific Counterfactuals
Source quote
L363: Since we have introduce a known shortcut behaviour on the tag signal, we expect a global explanation to correctly highlight the reliance on the tag signal in contaminated test images. To measure this we have previously introduced the confounder sensitivity metric~\citep{sun2023right}. Confounder sensitivity measures how many of the top 10% most significant pixels identified by the explanation fall on the synthetically added tag signal. We computed the confounder sensitivity using the positive class center of cardiomegaly, resulting in a score of 0.747. This indicates that 74.7% of
2024Attri-Net (with guidance) proposedConfounder sensitivity0.002split: test · guided · subset=synthetic shortcut test images · contamination=50% of cardiomegaly-positive samplesAttri-Net: A Globally and Locally Inherently Interpretable Model for Multi-Label Classification Using Class-Specific Counterfactuals
Source quote
L366: To further verify that adding guidance can direct the model towards using the correct features, we added the guidance shown in Fig.~\ref{fig:guidance_shortcut}(c) to the model to encourage the model to avoid using spurious signals. After adding guidance, the confounder sensitivity of the new class center dropped to 0.002, which means that the most significant explanation pixels are not on the spurious signals anymore.
2024Fair Diagnosis (ResNet50) proposedACC86.40%split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=genderFair Diagnosis: Leveraging Causal Modeling to Mitigate Medical Bias
Source quote
L283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34
2024Fair Diagnosis (ResNet50) proposed non-standard sliceADF (column label: ADF-e-3)1.34split: test · η=0.2 · backbone=ResNet50 · metric_scale=e-3 · train_test_split=90/10 · sensitive_attribute=genderFair Diagnosis: Leveraging Causal Modeling to Mitigate Medical Bias
Source quote
L283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34
2024RadGazeGen proposedAUC (Avg across 12 pathologies)71.33split: test · classes=12 pathologies · sample-size=500RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion Models
Source quote
L207: RadGazeGen │ 80.71 │ 70.34 │ 77.67 │ 73.47 │ 66.57 │ 88.20 │ 78.31 │ 53.29 │ 77.46 │ 62.74 │ 52.32 │ 74.90 │ 71.33
2024ResNet50 coarse classification (5 classes) proposedMacro F1 score0.7109classes=5 · backbone=ResNet50Learning to diagnose common thorax diseases on chest radiographs from radiology reports in Vietnamese
Source quote
L906: 0.7109
2024ResNet50 fine classification (12 classes) proposedMacro F1 score0.4849classes=12 · backbone=ResNet50Learning to diagnose common thorax diseases on chest radiographs from radiology reports in Vietnamese
Source quote
L908: 0.4849
2024MedPrompt-ViT proposedzero-shot image classification performance0.62200-shot · prompt=automatically generated · subset=five held-out classes · backbone=ViTExploring Low-Resource Medical Image Classification with Weakly Supervised Prompt Learning
Source quote
L201: MedPrompt-ViT (Ours) │ 0.6220 │ 0.5720 │ 0.7997 │ 0.7284
2024\imgedit (white-box) proposedEO_p28.5split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024\imgedit (white-box) proposedDI disparity (|1−DI|)25.6split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024\imgedit (white-box) proposedAcc75.1split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC72.24split: test · training-data=10%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L289: 72.24
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC91.02split: test · training-data=40%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L292: 91.02
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC98.21split: test · training-data=100%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L298: 98.21
2024UniMed-CLIP proposed non-standard sliceACC65.900-shot · subset=5x200 · backbone=CLIPUniMed-CLIP: Towards a Unified Image-Text Pretraining Paradigm for Diverse Medical Imaging Modalities
Source quote
L463: UniMed-CLIP │ 65.90 │ 71.65 │ 71.35 │ 66.31 │ 85.82 │ 85.27 │ 37.54 │ 24.43 │ 31.72
2024RANclassification performance score80.5γ=20 noise ratio; downstream chest classification. The comparison table does not specif…Light-weight Fine-tuning Method for Defending Adversarial Noise in Pre-trained Medical Vision-Language Models
Source quote
L315: RAN │ 81.8 │ 80.5
2024NMTuneclassification performance score79.6γ=20 noise ratio; downstream chest classification. The comparison table does not specif…Light-weight Fine-tuning Method for Defending Adversarial Noise in Pre-trained Medical Vision-Language Models
Source quote
L316: NMTune │ 80.7 │ 79.6
2024MSN+x-SMAUROC0.766split: test · linear-probe · backbone=ViT-TMulti-modal Masked Siamese Network Improves Chest X-Ray Representation Learning
Source quote
L550: MSN+ x-SM │ 0.766 (0.745, 0.786) \color{green}\uparrow\uparrow │ 0.402 (0.387, 0.427) \color{green}\uparrow │ \color{blue}{0.716^* (0.712, 0.719)} \color{green}\uparrow\uparrow │ \color{blue}{0.241^* (0.236, 0.249)} \color{green}\uparrow\uparrow
2024Subset 0 (approximately indistinguishable partition) non-standard sliceShare of evaluated patients29.6%split: test · subset=0 · holdout-size=500 radiographsHuman Expertise in Algorithmic Prediction
Source quote
L169: While \Cref{fig: radiologist v algo accuracy} found no significant differences between radiologists' and algorithms' overall performance, \Cref{fig: chexpert distinguishability} reveals a large subset --- subset 0, consisting of 29.6% of our sample --- where radiologists achieve a better MCC than every algorithm. In particular, every algorithm predicts a positive label for every patient in this subset, and radiologists identify a sizable fraction of true negatives that the algorithms miss. For example, radiologist 1 achieves a true positive rate of 84.0% and a true negative rate of 42.9%, while the algorithms achieve corresponding rates of 100% and 0%.
2024ResNet-18 baselineTest loss0.7712split: test · backbone=ResNet-18 · training-size=9250The Effect of Intrinsic Dataset Properties on Generalization: Unraveling Learning Differences Between Natural and Medical Images
Source quote
L484: 9250 │ 0.7712 │ 0.6370 │ 0.6789 │ 0.6014 │ 0.6014 │ 0.6016
2024ResNet-18 baselineTest loss1.3479split: test · backbone=ResNet-18 · training-size=1000The Effect of Intrinsic Dataset Properties on Generalization: Unraveling Learning Differences Between Natural and Medical Images
Source quote
L485: 1000 │ 1.3479 │ 0.7894 │ 0.9793 │ 0.6700 │ 0.7409 │ 0.6806
2024MGCA, real-only training baseline non-standard slicemean F1 score0.209split: test · 1-shot · backbone=MGCA · augmentation=real-only · training-data=1% ground-truthEvaluating and Improving the Effectiveness of Synthetic Chest X-Rays for Medical Image Analysis
Source quote
L34: In multilabel classification on CheXpert dataset, we also found it was most effective to generate the synthetic data using single-disease prompts (e.g. "cardiomegaly"), and the synthetic data was used to balance all classes to the count of the most frequent disease class. At 1% ground truth data, the mean F1 score increased from 0.209 with real data to 0.289 with 2x synthetic data. At 10% ground truth data, the F1 score improved from 0.255 to 0.323 with 2x synthetic data. At 100% ground truth data, synthetic data provided marginal improvements, with the F1 score increasing from 0.310 to 0.354 with balanced 2x synthetic augmentation (Figure \ref{fig:results}, Plot 4). These results demonstrate that the strategic addition of synthetic data can address class imbalance and significantly improve multilabel classification performance, especially in low-resource scenarios.
2024MMCLIP baselineAUC90.53split: test · 0-shot · subset=500 imagesXLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-Training
Source quote
L262: MMCLIP │ 90.53 │ 67.05 │ 86.04 │ 85.79 │ 33.50 │ 91.19 │ 86.16 │ 62.57 │ 80.46
2024MedKlip baselineAUC89.97split: test · 0-shot · subset=500 imagesXLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-Training
Source quote
L260: MedKlip \cite{wu2023medklip} │ 89.97 │ 63.67 │ 84.32 │ 84.97 │ 35.17 │ 90.68 │ 86.94 │ 63.42 │ 80.02
2024MSN baselineAUROC0.740split: test · linear-probe · backbone=ViT-TMulti-modal Masked Siamese Network Improves Chest X-Ray Representation Learning
Source quote
L534: MSN │ 0.740 (0.720, 0.763) │ 0.396 (0.382, 0.421) │ 0.676 (0.671, 0.68) │ 0.199 (0.197, 0.203)
2024SD baselineAUC (Avg across 12 pathologies)71.12split: test · classes=12 pathologies · sample-size=500RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion Models
Source quote
L204: SD │ 72.57 │ 73.64 │ 73.77 │ 75.28 │ 64.24 │ 83.32 │ 74.59 │ 68.07 │ 59.24 │ 58.36 │ 71.70 │ 78.67 │ 71.12
2024ViT-B baselinemAUC89.3%fine-tuned · backbone=ViT-B/16 · resolution=224×224Learning Low-Rank Feature for Thorax Disease Classification
Source quote
L312: ViT-B \citep{xiao2023delving} │ ViT-B/16 │ 82.7 │ 83.5 │ 89.3
2024MINE baselineAUROC87.7split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=invertedBenchmarking Dependence Measures to Prevent Shortcut Learning in Medical Imaging
Source quote
L157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4
2024Rebalance baselineAUROC79.8split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=invertedBenchmarking Dependence Measures to Prevent Shortcut Learning in Medical Imaging
Source quote
L156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8
2024MINE baselineAUROC92.4split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balancedBenchmarking Dependence Measures to Prevent Shortcut Learning in Medical Imaging
Source quote
L157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4
2024Rebalance baselineAUROC90.0split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balancedBenchmarking Dependence Measures to Prevent Shortcut Learning in Medical Imaging
Source quote
L156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8
2024Radiologist 1 baseline non-standard sliceTrue negative rate (TNR)42.9%split: test · subset=0 · ground-truth=majority vote of five radiologists · holdout-size=500 radiographsHuman Expertise in Algorithmic Prediction
Source quote
L169: While \Cref{fig: radiologist v algo accuracy} found no significant differences between radiologists' and algorithms' overall performance, \Cref{fig: chexpert distinguishability} reveals a large subset --- subset 0, consisting of 29.6% of our sample --- where radiologists achieve a better MCC than every algorithm. In particular, every algorithm predicts a positive label for every patient in this subset, and radiologists identify a sizable fraction of true negatives that the algorithms miss. For example, radiologist 1 achieves a true positive rate of 84.0% and a true negative rate of 42.9%, while the algorithms achieve corresponding rates of 100% and 0%.
2024Eight leaderboard algorithms baseline non-standard sliceTrue negative rate (TNR)0%split: test · models=eight leaderboard algorithms · subset=0 · ground-truth=majority vote of five radiologistsHuman Expertise in Algorithmic Prediction
Source quote
L169: While \Cref{fig: radiologist v algo accuracy} found no significant differences between radiologists' and algorithms' overall performance, \Cref{fig: chexpert distinguishability} reveals a large subset --- subset 0, consisting of 29.6% of our sample --- where radiologists achieve a better MCC than every algorithm. In particular, every algorithm predicts a positive label for every patient in this subset, and radiologists identify a sizable fraction of true negatives that the algorithms miss. For example, radiologist 1 achieves a true positive rate of 84.0% and a true negative rate of 42.9%, while the algorithms achieve corresponding rates of 100% and 0%.
2024MedCLIP-ViT baselinezero-shot image classification performance0.59420-shot · prompt=manual prompt ensemble · backbone=ViTExploring Low-Resource Medical Image Classification with Weakly Supervised Prompt Learning
Source quote
L200: MedCLIP-ViT \cite{7} │ 0.5942 │ 0.5024 │ 0.7943 │ 0.7682
2024BiasAdv baselineEO_p39.0split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L172: BiasAdv~\cite{lim2023biasadv} │ 39.0 │ 54.5 │ 58.2 │ 71.1 │ 36.0 │ 54.0 │ 77.1 │ 61.0 │ 39.0 │ 33.5 │ 36.6 │ 74.9
2024Batch Samp. baselineDI disparity (|1−DI|)51.8split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0
2024Batch Samp. baselineAcc74.3split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0
2024GESTALT baselineAUC70.82split: test · training-data=10%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L277: 70.82
2024GESTALT baselineAUC89.27split: test · training-data=40%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L280: 89.27
2024GESTALT baselineAUC96.71split: test · training-data=100%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L286: 96.71
2024Previous image baseline non-standard slicemacro-average AUROC0.572split: test · subset=Diff subsetTowards Predicting Temporal Changes in a Patient's Chest X-ray Images based on Electronic Health Records
Source quote
L482: Previous image │ 0.768 │ 0.846 │ 0.572
2023GAT (Gender auxiliary task) proposed non-standard sliceRobust AUC83.00attack=PGD-10 · target=Atelectasis · auxiliary-task=Gender · perturbation-budget=ℓ∞ ε=4/255GAT: Guided Adversarial Training with Pareto-optimal Auxiliary Tasks
Source quote
L887: Atelectasis │ Gender │ 83.00 │ 83.35
2023DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposedAUC89.24%split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023MGA(text-level) proposedAcc75.06view=frontal · averaged_over=8 diseasesMGA: Medical generalist agent through text-guided knowledge transformation
Source quote
L114: MGA(text-level) │ 86.48 │ 81.51 │ 71.01 │ \multicolumn{1}{l}{75.06} │ \multicolumn{1}{l}{69.91} │ \multicolumn{1}{l|}{82.32}
2023ELIXR-C proposedMean AUC0.850split: test · 0-shot · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L434: 0.850
2023ELIXR-B linear proposedMean AUC0.893split: test · linear-probe · findings=5 · training-data=1% (~2,200 images)ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L449: 0.893
2023CSDA (Ours; full proposed framework with VCQ) proposedAUC0.6792semi-supervised · labeled-samples=500Class-Specific Distribution Alignment for semi-supervised medical image classification
Source quote
L406: Ours │ 0.6499 │ 0.6619 │ 0.6694 │ 0.6762 │ 0.6792