Abstract
Medical imaging diagnosis presents inherent challenges due to diseases that mimic normal anatomy and exhibit significant inter-patient variability. Clinicians routinely employ comparative reasoning—using reference images from healthy controls or previous patient examinations—to discern subtle yet diagnostically critical abnormalities. However, existing medical vision-language models (VLMs) focus primarily on single-image analyses and lack explicit mechanisms for comparative reasoning. This work introduces See-in-Pairs (SiP), a framework that leverages reference images to enhance diagnostic accuracy. By providing general-purpose VLMs with query and normative matched reference images, accompanied by clinically-informed comparative prompts, we demonstrate significant performance improvements across multiple medical visual question answering (VQA) tasks. Our contributions highlight the clinical relevance of comparative analysis, introduce novel strategies for leveraging reference images in VLMs, and provide theoretical insights into the efficacy of comparative image analysis in medical diagnosis.
Introduction
Medical image diagnosis is inherently difficult because pathological abnormalities are often subtle and embedded within normal anatomical variations. Furthermore, significant inter-patient variability means that features appearing pathological in one individual may represent natural variation in another. In clinical practice, radiologists mitigate these challenges by comparing suspicious scans against known healthy baselines or a patient's prior examinations to identify deviations.
Despite the prevalence of this comparative protocol, most current medical AI models are "single-image" systems, trained to output labels from individual scans in isolation. This work addresses the lack of cross-subject comparative reasoning in medical VLMs, investigating whether providing an AI with a "healthy reference" image can help it filter out anatomical noise and focus on actual pathology.
The See-in-Pairs (SiP) Framework
The See-in-Pairs (SiP) pipeline mimics clinical comparative reasoning through three primary components:
- Comparative Inference: Instead of a single image, the VLM receives a triplet:
(Query Image, Healthy Reference Image, Comparative Prompt). The prompt explicitly directs the model to identify differences between the two images. - Reference Selection Strategies: The framework evaluates multiple methods for selecting the "healthy" reference, including random selection, demographic matching (age, sex), and embedding-based retrieval using models like BioMedCLIP to find visually similar healthy controls.
- Lightweight Supervised Fine-Tuning (SFT): Using Low-Rank Adaptation (LoRA), the language decoders of general-purpose VLMs (e.g., Qwen-VL, Phi-3.5, NVILA) are fine-tuned to process these comparative triplets without the prohibitive cost of full model retraining.
Experimental Evaluation
The SiP framework was evaluated across six diagnostic tasks spanning four imaging modalities:
- Radiology: Pneumonia and Edema detection using the CheXpert dataset.
- Ophthalmology: Glaucoma diagnosis (GF3300) and Retinopathy diagnosis (BRSET).
- Dermatology: Melanoma and multi-class diagnosis using the HAM10000 dataset.
Key Results and Insights
The empirical analysis yielded several critical findings:
- Bridging the Capability-Knowledge Gap: General-purpose VLMs possess the architectural capacity for multi-image comparison but lack specialized medical knowledge. Conversely, existing medical VLMs are often restricted to single-image reasoning. SiP effectively injects medical domain knowledge into comparison-capable architectures.
- Robustness to Reference Quality: Performance gains remained consistent even when using imperfectly matched reference images or references from different clinical centers. This suggests that the act of comparison itself helps the model establish a "normative distribution" of human anatomy.
- Enhanced Interpretability: Qualitative analysis using attribution maps (Figure 3b) demonstrates that SiP encourages models to ignore "nuisance" features, such as scanner artifacts or background noise, and focus on anatomically plausible, pathology-oriented regions.
- Quantitative Performance: SiP consistently outperformed single-image baselines across all tested models. For example, in retinopathy tasks, SiP enabled models to achieve over 81% Balanced Accuracy, a significant improvement over standard training protocols.
Conclusion
While the SiP framework introduces additional inference latency and requires a curated pool of healthy reference images, it represents a significant advancement toward more clinically-aligned medical AI. By leveraging the multi-image priors of general-purpose VLMs, SiP provides a scalable path for enhancing diagnostic accuracy in complex medical tasks. Future research will explore multi-hop reasoning and pre-training objectives that natively incorporate cross-subject comparison.