CheXpert
131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | final model (ensemble of the best performing networks) SOTA frontier | 0.94 | 2021-01-01 | labeling=majority vote of 3 board-certified radiologists · pathologies=5 · model-configuration=ensemble · Mean over 5 selected pathologies; validation studies use the majority vote of 3 board… | Interpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labelsSource quoteThe chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm] |
| 2 | DenseNet121-MaxAUC | 0.935 | 2023-01-01 | subset=five selected diseases · backbone=DenseNet121 · training-method=PES-AdaGrad · Mean across Cardiomegaly, Edema, Consolidation, Atelectasis, and Pleural Effusion. Ma… | Fast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL ConditionSource quoteDenseNet121-MaxAUC │ 0.901 │ 0.954 │ 0.954 │ 0.910 │ 0.957 │ 0.935 |
| 3 | FDAM (DenseNet161) (+1 variant) | 0.9333 | 2021-01-01 | K=2; training uses CheXpert and ChestXray8 data. Evaluated on CheXpert validation dat… | Federated Deep AUC Maximization for Hetergeneous Data with a Constant Communication ComplexitySource quote0.9333 |
| 4 | Proposed MARL framework (Ours, ResNet) | 0.925 | 2023-01-01 | backbone=ResNet · aggregation=maximum probability across views · model-count=single-model · label-handling=uncertain labels mapped to 1 · Validation set; mean over the five competition-task pathologies. Uncertain labels map… | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925 |
| 5 | Proposed instrumental variable learning framework | 0.923 | 2023-01-01 | uncertain-labels=mapped-to-1 · Average across five competition-task pathologies; the evaluation section states uncer… | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteMean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923 |
Showing 150 of 316 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard slice | AUROCf (failure-detection AUROC) | 0.487 | split: test | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL307: both models (0.487 and 0.536, with intervals including 0.5). |
| 2026 | Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard slice | AUROCf (failure-detection AUROC) | 0.536 | split: test · backbone=ViT-B/16 | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL307: both models (0.487 and 0.536, with intervals including 0.5). |
| 2026 | MedGemma-27B (Ours; symbolic entailment filtered) proposed | Soundness | 0.9599 | model=MedGemma-27B · params=27B · filtering=symbolic-entailment | Toward Guarantees for Clinical Reasoning in Vision Language Models via Formal VerificationSource quoteL187: \texttt{MedGemma-27B} │ 0.9301 │ 0.9599 │ +0.0298 │ 0.8231 │ 0.8107 │ -0.0124 │ -0.0601 │ +0.0024 |
| 2026 | MedGemma-27B (Ours; symbolic entailment filtered) proposed | Completeness | 0.8107 | model=MedGemma-27B · params=27B · filtering=symbolic-entailment | Toward Guarantees for Clinical Reasoning in Vision Language Models via Formal VerificationSource quoteL187: \texttt{MedGemma-27B} │ 0.9301 │ 0.9599 │ +0.0298 │ 0.8231 │ 0.8107 │ -0.0124 │ -0.0601 │ +0.0024 |
| 2026 | MedCLIP + GazeWorld proposed | Accuracy | 59.42 | 0-shot · subset=5×200 | A World Model of Radiologist Reading for Medical Image Representation LearningSource quoteL682: 58.13 │ 59.42 │ 56.85 |
| 2026 | VIVID-Med proposed | macro-AUC | 0.8588 | linear-probe | VIVID-Med: LLM-Supervised Structured Pretraining for Deployable Medical ViTsSource quoteL128: Table~\ref{tab:main_combined} summarizes performance on CheXpert and NIH. In-domain, VIVID-Med achieves an exceptional 0.8588 macro-AUC on CheXpert, outperforming BiomedCLIP by {+}6.65 points despite using 500× less pretraining data. Conversely, self-supervised baselines (MAE, DINOv3) show competitive F1s but substantially lower AUCs, highlighting their inability to capture clinical ranking structures without explicit semantic guidance. |
| 2026 | MedRAX + CRC-Router (TTA) proposed | Macro wrong-accept risk | 4.6% | split: test | CRC-Router: Risk-Constrained Routing for Medical Agentic AI SystemsSource quoteL186: Macro Risk │ 5.7% │ 4.8% │ 3.8% │ Macro Risk │ 20.9% │ 4.6% |
| 2026 | Full (Graph-of-Differences) proposed | R1↑ (Rank-1) | 0.3359 | 0-shot · evaluation=external-transfer | Graph-of-Differences: Anatomy-Structured Difference Alignment for Medical Image Re-IdentificationSource quoteL232: 0.9033 │ 0.8294 │ 0.3359 │ 0.3926 |
| 2026 | Causal conditioning (sampling) proposed | AUC of pleural effusion predictor | 82.33 | generation=sampling · conditioning=causal | To do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset AugmentationSource quoteL250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67 |
| 2026 | Causal conditioning (counterfactual generation) proposed | AUC of pleural effusion predictor | 81.67 | generation=counterfactual · conditioning=causal | To do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset AugmentationSource quoteL250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67 |
| 2026 | Grad-CAM, DenseNet-121 baseline | Pointing-game hit rate | 0.575 | 520 CheXpert findings with a radiologist localization benchmark; a hit is scored when t… | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL131: for 0.575 (0.529–0.619) of DenseNet-121 findings and |
| 2026 | Grad-CAM, ViT-B/16 baseline | Pointing-game hit rate | 0.381 | backbone=ViT-B/16 | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL132: 0.381 (0.336–0.425) of ViT-B/16 findings, against 0.888 |
| 2026 | Radiologists' most-representative-point localization baseline | Pointing-game hit rate | 0.888 | Radiologist reference performance on the 520 CheXpert findings with a localization benc… | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL132: 0.381 (0.336–0.425) of ViT-B/16 findings, against 0.888 |
| 2026 | UBAIA baseline | EOM | 0.745 | Individual Subgroup: Race; fairness result in the overall comparison table, not the rac… | Stride-Net: Fairness-Aware Disentangled Representation Learning for Chest X-Ray DiagnosisSource quoteL208: 0.895 │ {0.943} │ 0.745 |
| 2026 | No Adapt. baseline | mean AUROC | 76.0 | Main results table; seventh value in the target-domain block (aggregate). | Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray DiagnosisSource quoteL139: No Adapt. │ 56.6 │ 62.3 │ 67.4 │ 67.4 │ 64.1 │ 69.7 │ 64.6 │ 74.3 │ 71.7 │ 79.4 │ 80.8 │ 71.2 │ 78.3 │ 76.0 |
| 2026 | TENT baseline | mean AUROC | 77.4 | split: test · test-time-adaptation | Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray DiagnosisSource quoteL141: TENT │ 50.1 │ 50.1 │ 53.5 │ 55.3 │ 52.0 │ 63.0 │ 54.0 │ 77.7 │ 76.5 │ 80.6 │ 83.2 │ 65.5 │ 81.1 │ 77.4 |
| 2026 | MedGemma-27B (VLM; unfiltered) baseline | Soundness | 0.9301 | model=MedGemma-27B · params=27B · filtering=unfiltered | Toward Guarantees for Clinical Reasoning in Vision Language Models via Formal VerificationSource quoteL187: \texttt{MedGemma-27B} │ 0.9301 │ 0.9599 │ +0.0298 │ 0.8231 │ 0.8107 │ -0.0124 │ -0.0601 │ +0.0024 |
| 2026 | MedGemma-27B (VLM; unfiltered) baseline | Completeness | 0.8231 | model=MedGemma-27B · params=27B · filtering=unfiltered | Toward Guarantees for Clinical Reasoning in Vision Language Models via Formal VerificationSource quoteL187: \texttt{MedGemma-27B} │ 0.9301 │ 0.9599 │ +0.0298 │ 0.8231 │ 0.8107 │ -0.0124 │ -0.0601 │ +0.0024 |
| 2026 | OMIB (Wu et al., 2025) baseline | mAUC | 89.3% | split: test · subset=five diseases | IBMA: Information Bottleneck-Based Multimodal AlignmentSource quoteL479: 89.3 |
| 2026 | Baseline-WT baseline | WG accuracy | 71.0 | method-setting=inverse-frequency sample weighting using predicted spurious-label groups | SpurCon: Weighted Supervised Contrastive Learning for Mitigating Spurious Cues in Medical ImagingSource quoteL279: {71.0 } |
| 2026 | Deterministic conditioning (sampling) baseline | AUC of pleural effusion predictor | 80.65 | generation=sampling · conditioning=deterministic | To do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset AugmentationSource quoteL250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67 |
| 2026 | Undirected conditioning (sampling) baseline | AUC of pleural effusion predictor | 82.15 | generation=sampling · conditioning=undirected | To do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset AugmentationSource quoteL250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67 |
| 2026 | Deterministic conditioning (counterfactual generation) baseline | AUC of pleural effusion predictor | 79.79 | generation=counterfactual · conditioning=deterministic | To do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset AugmentationSource quoteL250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67 |
| 2026 | Undirected conditioning (counterfactual generation) baseline | AUC of pleural effusion predictor | 81.54 | generation=counterfactual · conditioning=undirected | To do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset AugmentationSource quoteL250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67 |
| 2025 | HiMed-3B proposed | RATE (RaTEScore) | 0.487 | params=3B | Beyond N-grams: A Hierarchical Reward Learning Framework for Clinically-Aware Medical Report GenerationSource quoteL287: HiMed-3B (\S) │ 0.182 │ 0.077 │ 0.032 │ 0.017 │ 0.163 │ 0.048 │ 0.157 │ 0.219 │ 0.487 |
| 2025 | DLDM (disentangled latent diffusion model) proposed | Effectiveness Accuracy | 88.7% | split: test · intervention=do(A=black) | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL558: DLDM │ 88.7 │ 91.8 │ 93.3 |
| 2025 | DLDM (disentangled latent diffusion model) proposed | FID score | 21.79 | FID of generated counterfactual images on the CheXpert dataset. | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL617: DLDM │ 21.79 │ 25.89 |
| 2025 | Autonomous distillation proposed | AUC | 0.92 | 0-shot | Turning Drift into Constraint: Robust Reasoning Alignment in Non-Stationary Multi-Stream EnvironmentsSource quoteL271: CARZero │ 0.84 │ 0.81 │ 0.92 │ 0.80 {\color[HTML]{FF0000} Ours} │ {\color[HTML]{FF0000} 0.85} │ {\color[HTML]{FF0000} 0.83} │ {\color[HTML]{FF0000} 0.92} │ {\color[HTML]{FF0000} 0.81} } |
| 2025 | Synthetic+Real mix model proposed | AUROC | 0.730 | split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained · evaluation-view=PA | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733), |
| 2025 | MedImageInsight zero-shot proposed | Acc | 80.5% | 0-shot · prompt=Impression | Beyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray PopulationsSource quoteL101: Comparing the image embeddings to parts of the radiology reports revealed notable performance boosts for the adult datasets. MIMIC performed best using (5) Findings as prompt (Acc = 78.0%, MCC = 0.57). CheXpert performed slightly better using (6) Impression (Acc = 80.5%, MCC = 0.62). |
| 2025 | MedImageInsight zero-shot proposed | MCC | 0.62 | 0-shot · prompt=Impression | Beyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray PopulationsSource quoteL101: Comparing the image embeddings to parts of the radiology reports revealed notable performance boosts for the adult datasets. MIMIC performed best using (5) Findings as prompt (Acc = 78.0%, MCC = 0.57). CheXpert performed slightly better using (6) Impression (Acc = 80.5%, MCC = 0.62). |
| 2025 | MedImageInsight zero-shot ensemble proposed | Absolute MCC difference across race subgroups | 10% | 0-shot · method=zero-shot ensemble · subgroup=race | Beyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray PopulationsSource quoteL419: Figure 3 (right) illustrates the absolute MCC differences across the demographic subgroups, sex, age, and race, in the CheXpert dataset. All evaluated methods exhibited varying levels of bias, reflected in performance differences across subgroups. ZS ensembling demonstrated a notable bias reduction compared to linear probing across all variables. For linear probing, differences ranged from 10% for sex, 14% for race, and up to 24% for age. In contrast, the ZS ensemble method achieved considerably lower bias levels, with the highest observed difference of 10% for race, while bias for sex and age remained below 5%. Although the ZS performance method demonstrated improved fairness compared to linear probing, methods such as LORA and KNN exhibited even smaller differences across all variables. |
| 2025 | Pragmatic listener (trained with pragmatic speaker, α=0.2) proposed | Listener accuracy | 98.72% | claims=4 · classes=2 · speaker-gamma=0.4 · candidate-utterances=4 · explanations-per-input=8 | Aligning Explanations with Human CommunicationSource quoteL121: CheXpert │ 2 │ 78.21% │ 4 │ 84.62% │ 98.72% |
| 2025 | XFMamba-S (frontal and lateral; cross-fusion; CVSM and MVCM enabled) proposed | AUROC | 0.9184 | views=frontal-and-lateral · epochs=100 · fusion=cross-fusion · backbone=VMamba-pretrained feature encoder · observations=13 | XFMamba: Cross-Fusion Mamba for Multi-view Medical Image ClassificationSource quoteL130: 8 │ Frontal \ │ Lateral │ cross-fusion │ \usym{2713} │ \usym{2713} │ 0.9184 |
| 2025 | ALTA proposed | Accuracy | 56.6% | 0-shot · subset=5×200 · resolution=224 | Efficient Medical Vision-Language Alignment Through Adapting Masked Vision ModelsSource quoteL286: Our ALTA │ 224 │ 83.2 │ 77.9 │ 91.0 │ 56.6 |
| 2025 | ALTA (adapter training) proposed | P@5, text-to-image retrieval | 64.5 | subset=8×200 · adapter=trained · patches=all retained | Efficient Medical Vision-Language Alignment Through Adapting Masked Vision ModelsSource quoteL529: Adapter training │ 51.3 │ 47.1 │ \multicolumn{1}{c|}{38.7} │ 64.5 │ 65.8 │ \multicolumn{1}{c|}{53.0} │ 56.8 │ 55.4 │ 46.8 |
| 2025 | ALTA (adapter training) proposed | P@5, image-to-text retrieval | 56.8 | subset=5×200 · adapter=trained · patches=all retained | Efficient Medical Vision-Language Alignment Through Adapting Masked Vision ModelsSource quoteL529: Adapter training │ 51.3 │ 47.1 │ \multicolumn{1}{c|}{38.7} │ 64.5 │ 65.8 │ \multicolumn{1}{c|}{53.0} │ 56.8 │ 55.4 │ 46.8 |
| 2025 | ART-ASyn proposed | AP | 0.8639 | Image-level anomaly detection. | ART-ASyn: Anatomy-aware Realistic Texture-based Anomaly Synthesis Framework for Chest X-RaysSource quoteL204: On the CheXpert dataset, ART-ASyn achieves an AP of 0.8639 and an AUC of 0.7125. It surpasses the second-best method in AP, UniAS, which achieves 0.7926, marking an improvement of 0.0713. While ART-ASyn achieves consistent gains on most metrics, its AUC on CheXpert is lower than AnatPaste's score of 0.7825. This discrepancy may be attributed to the base model architecture, as further discussed in the ablation study. |
| 2025 | EWC-Guided Diffusion Replay (DDPM+EWC) proposed | AUROC | 0.851 | split: val | EWC-Guided Diffusion Replay for Exemplar-Free Continual Learning in Medical ImagingSource quoteL4: Medical imaging foundation models must adapt over time, yet full retraining is often blocked by privacy constraints and cost. We present a continual learning framework that avoids storing patient exemplars by pairing class conditional diffusion replay with Elastic Weight Consolidation. Using a compact Vision Transformer backbone, we evaluate across eight MedMNIST v2 tasks and CheXpert. On CheXpert our approach attains 0.851 AUROC, reduces forgetting by more than 30% relative to DER\texttt{++}, and approaches joint training at 0.869 AUROC, while remaining efficient and privacy preserving. Analyses connect forgetting to two measurable factors: fidelity of replay and Fisher weighted parameter drift, highlighting the complementary roles of replay diffusion and synaptic stability. The results indicate a practical route for scalable, privacy aware continual adaptation of clinical imaging models. |
| 2025 | Stable Diffusion proposed | classification accuracy | 95% | retained-coverage=55% · uncertainty-filtered=45% of most uncertain samples removed | Conditional Diffusion Models are Medical Image Classifiers that Provide Explainability and Uncertainty for FreeSource quoteL16: In this work, we present a comprehensive evaluation of how conditional diffusion models can be re-purposed and leveraged for image classification, explainability, and uncertainty estimation in the medical domain. First, we propose a novel majority voting-based method that improves the performance of diffusion classifiers in medical imaging. We then demonstrate that classifiers derived from foundation and trained-from-scratch diffusion models perform competitively with state-of-the-art medical image discriminative classifiers through extensive experiments on the publicly available CheXpert~\cite{irvin2019chexpert} and ISIC Melanoma skin cancer~\cite{Rotemberg2020APD} datasets, despite not being trained for classification. Next, we show that diffusion classifiers offer explainability (via counterfactual generation) and uncertainty quantification (via entropy) out-of-the-box. We validate the uncertainty by showing that when the model is confident, it is correct, and vice versa. This is shown as model accuracy drastically improves as its uncertainty threshold increases. For example, Stable Diffusion reaches classification accuracies of 100% and 95% on ISIC and CheXpert, respectively, with only 45% of its most uncertain samples filtered out. |
| 2025 | MV-HFMD proposed | AUC-ROC | 0.775 | label-setting=average across five uncertain-label scenarios and 13 classification tasks | MCD-CLIP: Multi-view Chest Disease Diagnosis with Disentangled CLIPSource quoteL393: 0.775 |
| 2025 | MV-HFMD proposed | Tunable Param | 36.05 M | Number of tunable parameters reported for the method on CheXpert; not an averaged task … | MCD-CLIP: Multi-view Chest Disease Diagnosis with Disentangled CLIPSource quoteL392: 36.05 |
| 2025 | RR-ClArC (ResNet50) proposed | Accuracy (biased) | 0.79 | split: test · artifact=brightness · backbone=ResNet-50 | Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated dataSource quoteL1119: RR-ClArC │ {0.86} \,|\, {0.97} \,|\, {0.82} │ 0.76 \,|\, 0.96 \,|\, 0.79 │ 0.42 \,|\, {0.34} \,|\, - │ 0.00 \,|\, 0.07 \,|\, 0.00 |
| 2025 | U-Net + Text Encoder fine-tuning proposed | Accuracy | 94.8% | split: test · subset=No Finding · resolution=512×512 | Pixels Under Pressure: Exploring Fine-Tuning Paradigms for Foundation Models in High-Resolution Medical ImagingSource quoteL156: When evaluated on real test images after training on synthetic data (Table~\ref{tab:model_accuracy}), models fine-tuned on both U-Net and Text Encoder achieve the highest accuracy across nearly all disease categories (e.g., 77.9% for Cardiomegaly, 94.8% for No Finding), highlighting strong generalization. BitFit also performs surprisingly well in this evaluation, suggesting that while it may underperform in generation quality, its generated images still retain enough semantic structure to be informative for downstream classification. LoRA and DoRA also demonstrate robust cross-domain transfer, particularly in high-signal classes such as Pneumothorax and No Finding, underscoring their utility as efficient yet effective fine-tuning alternatives. |
| 2025 | CLIP fine-tuned with Palm2-bison fine-grained captions proposed | average per-class accuracy (Avg) | 72.5% | 0-shot · backbone=CLIP · caption-source=Palm2-bison · caption-granularity=fine | Enhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality LearningSource quoteL116: Palm2-bison~\cite{anil2023palm} │ fine │ 74.6 │ 70.7 │ 72.4 │ 77.6 │ 56.9 │ 84.5 │ 70.3 │ 80.2 │ 93.1 │ 37.1 │ 79.7 │ 72.5 |
| 2025 | CLIP fine-tuned with Zephyr-7b coarse-grained captions proposed | average per-class accuracy (Avg) | 53.2% | 0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=coarse | Enhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality LearningSource quoteL127: coarse │ 65.9 │ 41.8 │ 78.9 │ 56.9 │ 42.7 │ 85.8 │ 49.1 │ 71.6 │ 85.8 │ 3.4 │ 3.4 │ 53.2 |
| 2025 | CLIP fine-tuned with Zephyr-7b medium-grained captions proposed | average per-class accuracy (Avg) | 56.8% | 0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=medium | Enhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality LearningSource quoteL126: medium │ 66.4 │ 40.5 │ 82.8 │ 81.5 │ 48.7 │ 85.3 │ 46.1 │ 71.6 │ 85.3 │ 3.9 │ 12.9 │ 56.8 |
| 2025 | CLIP fine-tuned with Zephyr-7b fine-grained captions proposed | average per-class accuracy (Avg) | 64.1% | 0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=fine | Enhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality LearningSource quoteL125: \multirow[t]{3}{*}{zephyr-7b~\cite{tunstall2023zephyr}} │ fine │ 67.7 │ 43.1 │ 60.3 │ 60.3 │ 56.5 │ 83.2 │ 78.4 │ 79.3 │ 86.2 │ 62.5 │ 28.0 │ 64.1 |
| 2025 | Diff3M (Ours_demo) proposed | AUPRC | 0.931 | split: test · variant=Ours_demo · sampling=600-step DDIM · demographics=used | Harnessing EHRs for Diffusion-Based Anomaly Detection on Chest X-RaysSource quoteL181: AUPRC │ 0.888 │ 0.719 │ 0.889 │ 0.917 │ 0.931 |
| 2025 | AdvSimplex (Medical CLIP, CheXzero paradigm, ViT-B) proposed non-standard slice | PGD AUC | 0.735 | 0-shot · attack=PGD-20 · epsilon=1/255 · backbone=ViT-B | Improving Zero-Shot Adversarial Robustness in Vision-Language Models by Closed-form Alignment of Adversarial Path SimplicesSource quoteL1165: 0.735 |
| 2025 | Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposed | CFRT (Classifier Flip Rate along a Trajectory) | 0.78 | fine-tuned · trajectory=style · target-attribute=Pleural Effusion | Language-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image GenerationSource quoteL101: \multicolumn{1}{c|}{\multirow{2}{*}{CFRT\uparrow}} │ \multirow{2}{*}{0.78} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.89}} │ MEL │ 0.91 │ 0.99 │ 0.59 │ 0.74 |
| 2025 | Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposed | CFRT (Classifier Flip Rate along a Trajectory) | 0.89 | fine-tuned · trajectory=style · target-attribute=Support Devices | Language-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image GenerationSource quoteL101: \multicolumn{1}{c|}{\multirow{2}{*}{CFRT\uparrow}} │ \multirow{2}{*}{0.78} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.89}} │ MEL │ 0.91 │ 0.99 │ 0.59 │ 0.74 |
| 2025 | Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposed | LPIPS | 0.24 | fine-tuned · trajectory=style · target-attribute=Pleural Effusion | Language-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image GenerationSource quoteL103: \multicolumn{1}{c|}{\multirow{2}{*}{LPIPS\downarrow}} │ \multirow{2}{*}{0.24} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.05}} │ MEL │ 0.08 │ 0.09 │ 0.12 │ 0.11 |
| 2025 | SiP, cross-center reference selection (CC) proposed | BAcc. | 68.43 | finding=pneumonia · reference-source=MIMIC-CXR · reference-selection=cross-center | See-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical DiagnosisSource quoteL292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64 |
| 2025 | SiP, cross-center reference selection (CC) proposed | F1 | 67.15 | finding=pneumonia · reference-source=MIMIC-CXR · reference-selection=cross-center | See-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical DiagnosisSource quoteL292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64 |
| 2025 | SiP, cross-center reference selection (CC) proposed | BAcc. | 77.90 | finding=edema · reference-source=MIMIC-CXR · reference-selection=cross-center | See-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical DiagnosisSource quoteL292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64 |
| 2025 | SiP, cross-center reference selection (CC) proposed | F1 | 79.04 | finding=edema · reference-source=MIMIC-CXR · reference-selection=cross-center | See-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical DiagnosisSource quoteL292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64 |
| 2025 | SiP, random reference selection (RS) proposed | BAcc. | 68.70 | finding=pneumonia · reference-selection=random | See-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical DiagnosisSource quoteL295: RS │ 68.70 │ 67.05 │ \multicolumn{1}{c}{---} │ \multicolumn{1}{c}{---} |
| 2025 | SiP, random reference selection (RS) proposed | BAcc. | 78.04 | finding=edema · reference-selection=random | See-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical DiagnosisSource quoteL296: 78.04 │ 79.10 │ \multicolumn{1}{c}{---} │ \multicolumn{1}{c}{---} |
| 2025 | AGA proposed | Prec@5 | 50.28 | subset=5×200 | AGA: An adaptive group alignment framework for structured medical cross-modal representation learningSource quoteL237: AGA │ 50.28 │ 49.84 │ 43.80 |
| 2025 | AGA proposed | AUC | 56.10 | linear-probe · labeled-data=1% | AGA: An adaptive group alignment framework for structured medical cross-modal representation learningSource quoteL274: AGA │ 56.10 │ 61.31 │ 84.32 │ 68.91 │ 75.78 │ 87.92 |
| 2025 | Literal listener (trained with literal speaker, α=0.0) ablation | Listener accuracy | 84.62% | claims=4 · classes=2 · speaker-gamma=0.4 · candidate-utterances=4 · explanations-per-input=8 | Aligning Explanations with Human CommunicationSource quoteL121: CheXpert │ 2 │ 78.21% │ 4 │ 84.62% │ 98.72% |
| 2025 | XFMamba-S (frontal and lateral; early fusion) ablation | AUROC | 0.9090 | views=frontal-and-lateral · epochs=100 · fusion=early-fusion · backbone=VMamba-pretrained feature encoder · observations=13 | XFMamba: Cross-Fusion Mamba for Multi-view Medical Image ClassificationSource quoteL125: 3 │ Frontal \ │ Lateral │ early-fusion │ \usym{2717} │ \usym{2717} │ 0.9090 |
| 2025 | XFMamba-S (frontal and lateral; late fusion) ablation | AUROC | 0.9092 | views=frontal-and-lateral · epochs=100 · fusion=late-fusion · backbone=VMamba-pretrained feature encoder · observations=13 | XFMamba: Cross-Fusion Mamba for Multi-view Medical Image ClassificationSource quoteL126: 4 │ Frontal \ │ Lateral │ late-fusion │ \usym{2717} │ \usym{2717} │ 0.9092 |
| 2025 | XFMamba-S (lateral view only; no fusion) ablation | AUROC | 0.8961 | views=lateral-only · epochs=100 · fusion=none · backbone=VMamba-pretrained feature encoder · observations=13 | XFMamba: Cross-Fusion Mamba for Multi-view Medical Image ClassificationSource quoteL123: 1 │ Lateral │ no │ \usym{2717} │ \usym{2717} │ 0.8961 |
| 2025 | XFMamba-S (frontal view only; no fusion) ablation | AUROC | 0.9081 | views=frontal-only · epochs=100 · fusion=none · backbone=VMamba-pretrained feature encoder · observations=13 | XFMamba: Cross-Fusion Mamba for Multi-view Medical Image ClassificationSource quoteL124: 2 │ Frontal │ no │ \usym{2717} │ \usym{2717} │ 0.9081 |
| 2025 | Backbone score correlation (ordinary vs. soft metrics) | R² of Pearson correlation between ordinary and soft AUROC scores | 0.465 | label=Pneumothorax · comparison=ordinary-versus-soft AUROC across backbones | Clinical Uncertainty Impacts Machine Learning EvaluationsSource quoteL169: The analysis of the coefficients of determination R^2 in Figure~\ref{fig:DatasetAnalysis} shows that \gls*{ap} often decouples rankings between ordinary and soft settings moderately, and \gls*{auroc} can sometimes decouple them sharply (e.g., CheXpert--Pneumothorax AUROC R (2)\!=\!0.465 vs.\ AP R (2)\!=\!0.983). |
| 2025 | Backbone score correlation (ordinary vs. soft metrics) | R² of Pearson correlation between ordinary and soft AP scores | 0.983 | label=Pneumothorax · comparison=ordinary-versus-soft AP across backbones | Clinical Uncertainty Impacts Machine Learning EvaluationsSource quoteL169: The analysis of the coefficients of determination R^2 in Figure~\ref{fig:DatasetAnalysis} shows that \gls*{ap} often decouples rankings between ordinary and soft settings moderately, and \gls*{auroc} can sometimes decouple them sharply (e.g., CheXpert--Pneumothorax AUROC R (2)\!=\!0.465 vs.\ AP R (2)\!=\!0.983). |
| 2025 | MVMAE | Brier score | 0.0904 | linear-probe | Structure is Supervision: Multiview Masked Autoencoders for RadiologySource quoteL305: MVMAE (ours) │ 0.0832 │ 0.0904 │ 0.0660 │ 0.0759 |
| 2025 | Independent | Brier score | 0.0920 | linear-probe | Structure is Supervision: Multiview Masked Autoencoders for RadiologySource quoteL302: Independent │ 0.0841 │ 0.0920 │ 0.0670 │ 0.0769 |
| 2025 | Joint training | AUROC | 0.869 | Macro-averaged across five standard diagnosis labels; 95% CIs across 5 independent runs… | EWC-Guided Diffusion Replay for Exemplar-Free Continual Learning in Medical ImagingSource quoteL4: Medical imaging foundation models must adapt over time, yet full retraining is often blocked by privacy constraints and cost. We present a continual learning framework that avoids storing patient exemplars by pairing class conditional diffusion replay with Elastic Weight Consolidation. Using a compact Vision Transformer backbone, we evaluate across eight MedMNIST v2 tasks and CheXpert. On CheXpert our approach attains 0.851 AUROC, reduces forgetting by more than 30% relative to DER\texttt{++}, and approaches joint training at 0.869 AUROC, while remaining efficient and privacy preserving. Analyses connect forgetting to two measurable factors: fidelity of replay and Fisher weighted parameter drift, highlighting the complementary roles of replay diffusion and synaptic stability. The results indicate a practical route for scalable, privacy aware continual adaptation of clinical imaging models. |
| 2025 | MedGemma-27B baseline | RATE (RaTEScore) | 0.471 | params=27B | Beyond N-grams: A Hierarchical Reward Learning Framework for Clinically-Aware Medical Report GenerationSource quoteL276: MedGemma-27B (*) │ 0.117 │ 0.047 │ 0.018 │ 0.006 │ 0.165 │ 0.033 │ 0.153 │ 0.183 │ 0.471 |
| 2025 | CLDM (standard conditional latent diffusion model) baseline | Effectiveness Accuracy | 83.5% | split: test · intervention=do(A=black) | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL557: CLDM │ 83.5 │ 87.2 │ 89.1 |
| 2025 | CLDM (standard conditional latent diffusion model) baseline | FID score | 22.14 | FID of generated counterfactual images on the CheXpert dataset. | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL616: CLDM │ 22.14 │ 26.10 |
| 2025 | Real-only baseline baseline | AUROC | 0.700 | split: test · training-data=66k real MIMIC-CXR images · initialization=ImageNet-pretrained · evaluation-view=PA | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733), |
| 2025 | EfficientNet-b0 baseline | AUROC | 0.752 | label=Cardiomegaly · backbone=EfficientNet-b0 · metric-setting=ordinary | Clinical Uncertainty Impacts Machine Learning EvaluationsSource quoteL358: EfficientNet-b0 │ 0.752 │ 0.531 │ 0.683 │ 0.480 |
| 2025 | VGG-16 baseline | s-AUROC | 0.694 | label=Cardiomegaly · backbone=VGG-16 · metric-setting=soft | Clinical Uncertainty Impacts Machine Learning EvaluationsSource quoteL360: VGG-16 │ 0.717 │ 0.493 │ 0.694 │ 0.491 |
| 2025 | GLoRIA baseline | Average accuracy | 50.00% | split: test · fine-tuned · tasks=Consolidation; Pleural Effusion · image-view=frontal | Enhancing Biomedical Multi-modal Representation Learning with Multi-scale Pre-training and Perturbed Report DiscriminationSource quoteL142: GLoRIA \cite{huang2021gloria} │ 71.11% │ 28.89% │ 50.00% |
| 2025 | UniAS baseline | AP | 0.7926 | Image-level anomaly detection; identified as the second-best method in AP. | ART-ASyn: Anatomy-aware Realistic Texture-based Anomaly Synthesis Framework for Chest X-RaysSource quoteL204: On the CheXpert dataset, ART-ASyn achieves an AP of 0.8639 and an AUC of 0.7125. It surpasses the second-best method in AP, UniAS, which achieves 0.7926, marking an improvement of 0.0713. While ART-ASyn achieves consistent gains on most metrics, its AUC on CheXpert is lower than AnatPaste's score of 0.7825. This discrepancy may be attributed to the base model architecture, as further discussed in the ablation study. |
| 2025 | AIMv2 ViT-H baseline | ROC-AUC | 0.819 | fine-tuned · model=AIMv2 · backbone=ViT-H | Advancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation ModelsSource quoteL145: ViT-H │ 0.731 │ 0.807 │ 0.819 │ 0.815 |
| 2025 | DINOv2 ViT-L baseline | ROC-AUC | 0.814 | fine-tuned · model=DINOv2 · backbone=ViT-L | Advancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation ModelsSource quoteL134: ViT-L │ 0.731 │ 0.801 │ 0.814 │ 0.813 |
| 2025 | AIMv2 ViT-H baseline | ROC-AUC | 0.731 | linear-probe · model=AIMv2 · backbone=ViT-H | Advancements in Medical Image Classification through Fine-Tuning Natural Domain Foundation ModelsSource quoteL145: ViT-H │ 0.731 │ 0.807 │ 0.819 │ 0.815 |
| 2025 | DualNet baseline | AUC-ROC | 0.738 | label-setting=average across five uncertain-label scenarios and 13 classification tasks | MCD-CLIP: Multi-view Chest Disease Diagnosis with Disentangled CLIPSource quoteL384: 0.738 |
| 2025 | Vanilla (ResNet50) baseline | Accuracy (biased) | 0.44 | split: test · artifact=brightness · backbone=ResNet-50 | Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated dataSource quoteL1115: Vanilla │ {0.87} \,|\, {0.97} \,|\, {0.81} │ {0.28} \,|\, {0.62} \,|\, {0.44} │ {0.55} \,|\, {0.51} \,|\, - │ {0.17} \,|\, {0.30} \,|\, {0.33} |
| 2025 | CLIP fine-tuned using Human Expert captions baseline | average per-class accuracy (Avg) | 49.9% | 0-shot · backbone=CLIP · caption-source=Human Expert | Enhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality LearningSource quoteL115: Human Expert~\cite{johnson2019mimiccxrjpg} │ 34.5 │ 29.3 │ 64.2 │ 54.7 │ 54.3 │ 56.0 │ 66.8 │ 65.9 │ 44.8 │ 39.7 │ 39.2 │ 49.9 |
| 2025 | Baseline (ResNet50) baseline | Worst-group accuracy (WGAcc) | 25.87% | split: test · folds=4 held-out · backbone=ResNet50 · evaluation=test-time attenuation | Localising Shortcut Learning in Pixel Space via Ordinal Scoring Correlations for Attribution Representations (OSCAR)Source quoteL590: ResNet50 │ CheXpert │ Baseline │ 65.61 │ 25.87 |
| 2025 | DiAD baseline | AUPRC | 0.917 | split: test | Harnessing EHRs for Diffusion-Based Anomaly Detection on Chest X-RaysSource quoteL181: AUPRC │ 0.888 │ 0.719 │ 0.889 │ 0.917 │ 0.931 |
| 2025 | ODP-Bench prediction algorithms (10-algorithm Avg.) baseline | Spearman’s rank correlation (ρ) | -0.248 | aggregation=10-algorithm average · target_group=ill females | ODP-Bench: Benchmarking Out-of-Distribution Performance PredictionSource quoteL194: Dataset │ ATC │ Nu. Norm │ DOC │ NI │ MaNo │ Dispersion │ MDE │ Agreement │ COT │ COTT │ Avg. │ \#Effective CIFAR-10-C │ 0.951 │ 0.934 │ 0.884 │ 0.818 │ 0.836 │ 0.903 │ -0.832 │ 0.991 │ 0.980 │ 0.990 │ 0.746 │ 9 CIFAR-100-C │ 0.948 │ 0.829 │ 0.874 │ 0.868 │ 0.738 │ 0.718 │ -0.703 │ 0.971 │ 0.892 │ 0.985 │ 0.712 │ 9 NICO++ │ 0.970 │ 0.797 │ 0.742 │ 0.929 │ 0.846 │ 0.802 │ -0.777 │ 0.932 │ 0.844 │ 0.965 │ 0.705 │ 9 OfficeHome │ 0.911 │ 0.594 │ 0.465 │ 0.912 │ 0.754 │ 0.541 │ -0.409 │ 0.936 │ 0.693 │ 0.933 │ 0.633 │ 5 ObjectNet │ 0.794 │ 0.674 │ 0.640 │ 0.875 │ 0.672 │ 0.689 │ -0.670 │ 0.973 │ 0.706 │ 0.845 │ 0.620 │ 5 ImageNet-C │ 0.933 │ 0.596 │ 0.556 │ 0.790 │ 0.453 │ 0.581 │ -0.506 │ 0.933 │ 0.583 │ 0.839 │ 0.576 │ 4 ImageNet-V2 │ 0.993 │ 0.260 │ 0.958 │ 0.845 │ 0.149 │ 0.323 │ -0.216 │ 0.996 │ 0.357 │ 0.986 │ 0.565 │ 5 ImageNet-S │ 0.961 │ 0.500 │ 0.480 │ 0.846 │ 0.343 │ 0.438 │ -0.384 │ 0.838 │ 0.582 │ 0.987 │ 0.559 │ 4 PACS │ 0.708 │ 0.769 │ 0.657 │ 0.825 │ 0.489 │ 0.772 │ -0.736 │ 0.909 │ 0.498 │ 0.636 │ 0.553 │ 5 CIFAR-10.1 │ 0.717 │ 0.526 │ 0.423 │ 0.766 │ 0.524 │ 0.533 │ -0.524 │ 0.850 │ 0.556 │ 0.718 │ 0.509 │ 4 CIFAR-10.2 │ 0.780 │ 0.511 │ 0.364 │ 0.800 │ 0.511 │ 0.511 │ -0.508 │ 0.807 │ 0.541 │ 0.750 │ 0.507 │ 4 ImageNet-R │ 0.742 │ 0.325 │ 0.338 │ 0.859 │ 0.414 │ 0.232 │ -0.278 │ 0.926 │ 0.404 │ 0.885 │ 0.485 │ 4 TinyImageNet-C │ 0.617 │ 0.553 │ 0.454 │ 0.530 │ 0.487 │ 0.274 │ -0.343 │ 0.740 │ 0.583 │ 0.839 │ 0.473 │ 2 DomainNet │ 0.841 │ 0.563 │ 0.344 │ 0.235 │ 0.624 │ 0.563 │ -0.565 │ 0.433 │ 0.601 │ 0.874 │ 0.451 │ 2 STL-10 │ 0.718 │ 0.432 │ 0.003 │ 0.825 │ 0.412 │ 0.419 │ -0.402 │ 0.771 │ 0.567 │ 0.745 │ 0.449 │ 4 FMoW │ 0.964 │ 0.716 │ 0.172 │ 0.299 │ -0.305 │ 0.678 │ -0.674 │ 0.859 │ 0.681 │ 0.955 │ 0.435 │ 4 CINIC-10 │ 0.706 │ 0.318 │ -0.075 │ 0.867 │ 0.320 │ 0.307 │ -0.301 │ 0.794 │ 0.423 │ 0.728 │ 0.409 │ 4 VLCS │ 0.472 │ -0.036 │ 0.142 │ 0.699 │ 0.520 │ 0.145 │ 0.060 │ 0.777 │ 0.112 │ 0.457 │ 0.335 │ 1 iWildCam │ 0.669 │ 0.103 │ 0.341 │ 0.540 │ 0.023 │ 0.273 │ 0.012 │ 0.508 │ 0.190 │ 0.618 │ 0.328 │ 0 ImageNet-Vid │ -0.095 │ 0.712 │ -0.690 │ 0.556 │ 0.606 │ 0.648 │ -0.597 │ 0.654 │ 0.743 │ 0.737 │ 0.328 │ 3 RxRx1 │ 0.983 │ 0.882 │ -0.738 │ -0.538 │ -0.356 │ 0.863 │ -0.888 │ 0.979 │ 0.885 │ 0.979 │ 0.305 │ 6 ImageNet-A │ 0.503 │ 0.135 │ 0.208 │ 0.818 │ 0.209 │ 0.143 │ -0.158 │ 0.197 │ 0.122 │ 0.530 │ 0.270 │ 1 Amazon │ 0.749 │ 0.077 │ -0.225 │ 0.091 │ 0.073 │ -0.131 │ 0.810 │ 0.123 │ 0.640 │ 0.245 │ 3 Camelyon17 │ 0.296 │ 0.632 │ -0.506 │ -0.513 │ 0.056 │ 0.747 │ 0.315 │ -0.637 │ 0.796 │ 0.668 │ 0.185 │ 2 TerraInc │ 0.370 │ 0.440 │ 0.282 │ 0.355 │ -0.067 │ 0.438 │ -0.482 │ 0.422 │ -0.122 │ -0.062 │ 0.157 │ 0 CivilComments │ 0.806 │ -0.779 │ -0.096 │ 0.454 │ -0.850 │ 0.496 │ 0.818 │ -0.350 │ 0.537 │ 0.115 │ 3 Waterbirds │ 0.219 │ 0.449 │ 0.825 │ -0.194 │ 0.149 │ 0.475 │ 0.037 │ 0.473 │ -0.960 │ -0.883 │ 0.059 │ 1 CelebA │ 0.392 │ 0.498 │ 0.369 │ 0.027 │ 0.463 │ 0.602 │ -0.350 │ 0.162 │ -0.922 │ -0.825 │ 0.042 │ 0 CheXpert │ 0.052 │ 0.327 │ -0.752 │ -0.786 │ -0.472 │ 0.782 │ 0.535 │ -0.530 │ -0.786 │ -0.853 │ -0.248 │ 1 |
| 2025 | MGCA baseline | Prec@5 | 49.54 | subset=5×200 | AGA: An adaptive group alignment framework for structured medical cross-modal representation learningSource quoteL235: MGCA\cite{7} │ 49.54 │ 49.10 │ 42.25 |
| 2025 | MGCA baseline | AUC | 55.21 | linear-probe · labeled-data=1% | AGA: An adaptive group alignment framework for structured medical cross-modal representation learningSource quoteL272: MGCA\cite{7} │ 55.21 │ 59.21 │ 83.92 │ 67.28 │ 76.12 │ 87.76 |
| 2024 | HybridMED proposed | Acc | 0.448 | 0-shot · subset=5×200 · pretraining-dataset=MIMIC-CXR | Advancing Medical Radiograph Representation Learning: A Hybrid Pre-training Paradigm with Multilevel Semantic GranularitySource quoteL201: Ours │ MIMIC-CXR │ 0.800 │ 0.448 |
| 2024 | FactMM-RAG proposed | F1CheXbert | 0.491 | retrieval-setting=multimodal | Fact-Aware Multimodal Retrieval Augmentation for Accurate Medical Radiology Report GenerationSource quoteL269: FactMM-RAG │ 0.605 │ 0.249 │ 0.297 │ 0.547 │ 0.491 │ 0.174 │ 0.237 │ 0.467 |
| 2024 | FactMM-RAG proposed | F1RadGraph | 0.174 | retrieval-setting=multimodal | Fact-Aware Multimodal Retrieval Augmentation for Accurate Medical Radiology Report GenerationSource quoteL269: FactMM-RAG │ 0.605 │ 0.249 │ 0.297 │ 0.547 │ 0.491 │ 0.174 │ 0.237 │ 0.467 |
| 2024 | MGCA with 2x synthetic augmentation using single-disease prompts proposed non-standard slice | mean F1 score | 0.289 | split: test · 1-shot · prompt=single-disease · backbone=MGCA · training-data=1% ground-truth · synthetic-augmentation=2x | Evaluating and Improving the Effectiveness of Synthetic Chest X-Rays for Medical Image AnalysisSource quoteL34: In multilabel classification on CheXpert dataset, we also found it was most effective to generate the synthetic data using single-disease prompts (e.g. "cardiomegaly"), and the synthetic data was used to balance all classes to the count of the most frequent disease class. At 1% ground truth data, the mean F1 score increased from 0.209 with real data to 0.289 with 2x synthetic data. At 10% ground truth data, the F1 score improved from 0.255 to 0.323 with 2x synthetic data. At 100% ground truth data, synthetic data provided marginal improvements, with the F1 score increasing from 0.310 to 0.354 with balanced 2x synthetic augmentation (Figure \ref{fig:results}, Plot 4). These results demonstrate that the strategic addition of synthetic data can address class imbalance and significantly improve multilabel classification performance, especially in low-resource scenarios. |
| 2024 | GCD g-direction proposed | FR(\uparrow) | 91.1% | split: val · directions-per-disease=1 | Global Counterfactual DirectionsSource quoteL183: Pleural effusion │ \makecell{0.7863} │ \makecell{0.4126} │ \makecell{91.1} |
| 2024 | GCD g-direction proposed | FR(\uparrow) | 91.4% | split: val · directions-per-disease=1 | Global Counterfactual DirectionsSource quoteL184: Lung opacity │ \makecell{0.8430} │ \makecell{0.2171} │ \makecell{91.4} |
| 2024 | GCD g-direction proposed | FR(\uparrow) | 89.4% | split: val · directions-per-disease=1 | Global Counterfactual DirectionsSource quoteL185: Support devices │ \makecell{0.8247} │ \makecell{0.2321} │ \makecell{89.4} |
| 2024 | LLaVA-Med (PT2) proposed | F1 | 23.2 | split: test · prompt=PT2 · category=Edema | Prompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question AnsweringSource quoteL242: F1 │ 23.2 │ 42.6 |
| 2024 | LLaVA-Med (PT3) proposed | F1 | 42.6 | split: test · prompt=PT3 · category=Edema | Prompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question AnsweringSource quoteL242: F1 │ 23.2 │ 42.6 |
| 2024 | LLaVA-Med (PT2) proposed | false positive count | 410 count | split: test · prompt=PT2 · category=Edema | Prompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question AnsweringSource quoteL263: Edema │ 410 │ 88 |
| 2024 | LLaVA-Med (PT3) proposed | false positive count | 88 count | split: test · prompt=PT3 · category=Edema | Prompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question AnsweringSource quoteL263: Edema │ 410 │ 88 |
| 2024 | EGMA proposed | Acc. | 60.50 | 0-shot · subset=5x200 | Eye-gaze Guided Multi-modal Alignment for Medical Representation LearningSource quoteL293: EGMA(Ours) │ 60.50 │ 58.44 │ 57.81 │ {36.70} │ 63.62 │ 61.46 |
| 2024 | EGMA proposed | F1 | 58.44 | 0-shot · subset=5x200 | Eye-gaze Guided Multi-modal Alignment for Medical Representation LearningSource quoteL293: EGMA(Ours) │ 60.50 │ 58.44 │ 57.81 │ {36.70} │ 63.62 │ 61.46 |
| 2024 | Attri-Net (unguided) proposed | Confounder sensitivity | 0.747 | split: test · unguided · subset=synthetic shortcut test images · contamination=50% of cardiomegaly-positive samples | Attri-Net: A Globally and Locally Inherently Interpretable Model for Multi-Label Classification Using Class-Specific CounterfactualsSource quoteL363: Since we have introduce a known shortcut behaviour on the tag signal, we expect a global explanation to correctly highlight the reliance on the tag signal in contaminated test images. To measure this we have previously introduced the confounder sensitivity metric~\citep{sun2023right}. Confounder sensitivity measures how many of the top 10% most significant pixels identified by the explanation fall on the synthetically added tag signal. We computed the confounder sensitivity using the positive class center of cardiomegaly, resulting in a score of 0.747. This indicates that 74.7% of |
| 2024 | Attri-Net (with guidance) proposed | Confounder sensitivity | 0.002 | split: test · guided · subset=synthetic shortcut test images · contamination=50% of cardiomegaly-positive samples | Attri-Net: A Globally and Locally Inherently Interpretable Model for Multi-Label Classification Using Class-Specific CounterfactualsSource quoteL366: To further verify that adding guidance can direct the model towards using the correct features, we added the guidance shown in Fig.~\ref{fig:guidance_shortcut}(c) to the model to encourage the model to avoid using spurious signals. After adding guidance, the confounder sensitivity of the new class center dropped to 0.002, which means that the most significant explanation pixels are not on the spurious signals anymore. |
| 2024 | Fair Diagnosis (ResNet50) proposed | ACC | 86.40% | split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=gender | Fair Diagnosis: Leveraging Causal Modeling to Mitigate Medical BiasSource quoteL283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34 |
| 2024 | Fair Diagnosis (ResNet50) proposed non-standard slice | ADF (column label: ADF-e-3) | 1.34 | split: test · η=0.2 · backbone=ResNet50 · metric_scale=e-3 · train_test_split=90/10 · sensitive_attribute=gender | Fair Diagnosis: Leveraging Causal Modeling to Mitigate Medical BiasSource quoteL283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34 |
| 2024 | RadGazeGen proposed | AUC (Avg across 12 pathologies) | 71.33 | split: test · classes=12 pathologies · sample-size=500 | RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion ModelsSource quoteL207: RadGazeGen │ 80.71 │ 70.34 │ 77.67 │ 73.47 │ 66.57 │ 88.20 │ 78.31 │ 53.29 │ 77.46 │ 62.74 │ 52.32 │ 74.90 │ 71.33 |
| 2024 | ResNet50 coarse classification (5 classes) proposed | Macro F1 score | 0.7109 | classes=5 · backbone=ResNet50 | Learning to diagnose common thorax diseases on chest radiographs from radiology reports in VietnameseSource quoteL906: 0.7109 |
| 2024 | ResNet50 fine classification (12 classes) proposed | Macro F1 score | 0.4849 | classes=12 · backbone=ResNet50 | Learning to diagnose common thorax diseases on chest radiographs from radiology reports in VietnameseSource quoteL908: 0.4849 |
| 2024 | MedPrompt-ViT proposed | zero-shot image classification performance | 0.6220 | 0-shot · prompt=automatically generated · subset=five held-out classes · backbone=ViT | Exploring Low-Resource Medical Image Classification with Weakly Supervised Prompt LearningSource quoteL201: MedPrompt-ViT (Ours) │ 0.6220 │ 0.5720 │ 0.7997 │ 0.7284 |
| 2024 | \imgedit (white-box) proposed | EO_p | 28.5 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | \imgedit (white-box) proposed | DI disparity (|1−DI|) | 25.6 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | \imgedit (white-box) proposed | Acc | 75.1 | split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6 |
| 2024 | DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposed | AUC | 72.24 | split: test · training-data=10% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL289: 72.24 |
| 2024 | DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposed | AUC | 91.02 | split: test · training-data=40% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL292: 91.02 |
| 2024 | DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposed | AUC | 98.21 | split: test · training-data=100% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL298: 98.21 |
| 2024 | UniMed-CLIP proposed non-standard slice | ACC | 65.90 | 0-shot · subset=5x200 · backbone=CLIP | UniMed-CLIP: Towards a Unified Image-Text Pretraining Paradigm for Diverse Medical Imaging ModalitiesSource quoteL463: UniMed-CLIP │ 65.90 │ 71.65 │ 71.35 │ 66.31 │ 85.82 │ 85.27 │ 37.54 │ 24.43 │ 31.72 |
| 2024 | RAN | classification performance score | 80.5 | γ=20 noise ratio; downstream chest classification. The comparison table does not specif… | Light-weight Fine-tuning Method for Defending Adversarial Noise in Pre-trained Medical Vision-Language ModelsSource quoteL315: RAN │ 81.8 │ 80.5 |
| 2024 | NMTune | classification performance score | 79.6 | γ=20 noise ratio; downstream chest classification. The comparison table does not specif… | Light-weight Fine-tuning Method for Defending Adversarial Noise in Pre-trained Medical Vision-Language ModelsSource quoteL316: NMTune │ 80.7 │ 79.6 |
| 2024 | MSN+x-SM | AUROC | 0.766 | split: test · linear-probe · backbone=ViT-T | Multi-modal Masked Siamese Network Improves Chest X-Ray Representation LearningSource quoteL550: MSN+ x-SM │ 0.766 (0.745, 0.786) \color{green}\uparrow\uparrow │ 0.402 (0.387, 0.427) \color{green}\uparrow │ \color{blue}{0.716^* (0.712, 0.719)} \color{green}\uparrow\uparrow │ \color{blue}{0.241^* (0.236, 0.249)} \color{green}\uparrow\uparrow |
| 2024 | Subset 0 (approximately indistinguishable partition) non-standard slice | Share of evaluated patients | 29.6% | split: test · subset=0 · holdout-size=500 radiographs | Human Expertise in Algorithmic PredictionSource quoteL169: While \Cref{fig: radiologist v algo accuracy} found no significant differences between radiologists' and algorithms' overall performance, \Cref{fig: chexpert distinguishability} reveals a large subset --- subset 0, consisting of 29.6% of our sample --- where radiologists achieve a better MCC than every algorithm. In particular, every algorithm predicts a positive label for every patient in this subset, and radiologists identify a sizable fraction of true negatives that the algorithms miss. For example, radiologist 1 achieves a true positive rate of 84.0% and a true negative rate of 42.9%, while the algorithms achieve corresponding rates of 100% and 0%. |
| 2024 | ResNet-18 baseline | Test loss | 0.7712 | split: test · backbone=ResNet-18 · training-size=9250 | The Effect of Intrinsic Dataset Properties on Generalization: Unraveling Learning Differences Between Natural and Medical ImagesSource quoteL484: 9250 │ 0.7712 │ 0.6370 │ 0.6789 │ 0.6014 │ 0.6014 │ 0.6016 |
| 2024 | ResNet-18 baseline | Test loss | 1.3479 | split: test · backbone=ResNet-18 · training-size=1000 | The Effect of Intrinsic Dataset Properties on Generalization: Unraveling Learning Differences Between Natural and Medical ImagesSource quoteL485: 1000 │ 1.3479 │ 0.7894 │ 0.9793 │ 0.6700 │ 0.7409 │ 0.6806 |
| 2024 | MGCA, real-only training baseline non-standard slice | mean F1 score | 0.209 | split: test · 1-shot · backbone=MGCA · augmentation=real-only · training-data=1% ground-truth | Evaluating and Improving the Effectiveness of Synthetic Chest X-Rays for Medical Image AnalysisSource quoteL34: In multilabel classification on CheXpert dataset, we also found it was most effective to generate the synthetic data using single-disease prompts (e.g. "cardiomegaly"), and the synthetic data was used to balance all classes to the count of the most frequent disease class. At 1% ground truth data, the mean F1 score increased from 0.209 with real data to 0.289 with 2x synthetic data. At 10% ground truth data, the F1 score improved from 0.255 to 0.323 with 2x synthetic data. At 100% ground truth data, synthetic data provided marginal improvements, with the F1 score increasing from 0.310 to 0.354 with balanced 2x synthetic augmentation (Figure \ref{fig:results}, Plot 4). These results demonstrate that the strategic addition of synthetic data can address class imbalance and significantly improve multilabel classification performance, especially in low-resource scenarios. |
| 2024 | MMCLIP baseline | AUC | 90.53 | split: test · 0-shot · subset=500 images | XLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-TrainingSource quoteL262: MMCLIP │ 90.53 │ 67.05 │ 86.04 │ 85.79 │ 33.50 │ 91.19 │ 86.16 │ 62.57 │ 80.46 |
| 2024 | MedKlip baseline | AUC | 89.97 | split: test · 0-shot · subset=500 images | XLIP: Cross-modal Attention Masked Modelling for Medical Language-Image Pre-TrainingSource quoteL260: MedKlip \cite{wu2023medklip} │ 89.97 │ 63.67 │ 84.32 │ 84.97 │ 35.17 │ 90.68 │ 86.94 │ 63.42 │ 80.02 |
| 2024 | MSN baseline | AUROC | 0.740 | split: test · linear-probe · backbone=ViT-T | Multi-modal Masked Siamese Network Improves Chest X-Ray Representation LearningSource quoteL534: MSN │ 0.740 (0.720, 0.763) │ 0.396 (0.382, 0.421) │ 0.676 (0.671, 0.68) │ 0.199 (0.197, 0.203) |
| 2024 | SD baseline | AUC (Avg across 12 pathologies) | 71.12 | split: test · classes=12 pathologies · sample-size=500 | RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion ModelsSource quoteL204: SD │ 72.57 │ 73.64 │ 73.77 │ 75.28 │ 64.24 │ 83.32 │ 74.59 │ 68.07 │ 59.24 │ 58.36 │ 71.70 │ 78.67 │ 71.12 |
| 2024 | ViT-B baseline | mAUC | 89.3% | fine-tuned · backbone=ViT-B/16 · resolution=224×224 | Learning Low-Rank Feature for Thorax Disease ClassificationSource quoteL312: ViT-B \citep{xiao2023delving} │ ViT-B/16 │ 82.7 │ 83.5 │ 89.3 |
| 2024 | MINE baseline | AUROC | 87.7 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=inverted | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4 |
| 2024 | Rebalance baseline | AUROC | 79.8 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=inverted | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8 |
| 2024 | MINE baseline | AUROC | 92.4 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balanced | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL157: MINE │ 93.8 │ 87.7 │ 92.4 │ 98.5 │ 97.6 │ 96.4 |
| 2024 | Rebalance baseline | AUROC | 90.0 | split: test · disease=pleural-effusion · evaluation=5-fold-cross-validation · test-distribution=balanced | Benchmarking Dependence Measures to Prevent Shortcut Learning in Medical ImagingSource quoteL156: Rebalance │ 79.8 │ 90.0 │ 96.2 │ 96.8 |
| 2024 | Radiologist 1 baseline non-standard slice | True negative rate (TNR) | 42.9% | split: test · subset=0 · ground-truth=majority vote of five radiologists · holdout-size=500 radiographs | Human Expertise in Algorithmic PredictionSource quoteL169: While \Cref{fig: radiologist v algo accuracy} found no significant differences between radiologists' and algorithms' overall performance, \Cref{fig: chexpert distinguishability} reveals a large subset --- subset 0, consisting of 29.6% of our sample --- where radiologists achieve a better MCC than every algorithm. In particular, every algorithm predicts a positive label for every patient in this subset, and radiologists identify a sizable fraction of true negatives that the algorithms miss. For example, radiologist 1 achieves a true positive rate of 84.0% and a true negative rate of 42.9%, while the algorithms achieve corresponding rates of 100% and 0%. |
| 2024 | Eight leaderboard algorithms baseline non-standard slice | True negative rate (TNR) | 0% | split: test · models=eight leaderboard algorithms · subset=0 · ground-truth=majority vote of five radiologists | Human Expertise in Algorithmic PredictionSource quoteL169: While \Cref{fig: radiologist v algo accuracy} found no significant differences between radiologists' and algorithms' overall performance, \Cref{fig: chexpert distinguishability} reveals a large subset --- subset 0, consisting of 29.6% of our sample --- where radiologists achieve a better MCC than every algorithm. In particular, every algorithm predicts a positive label for every patient in this subset, and radiologists identify a sizable fraction of true negatives that the algorithms miss. For example, radiologist 1 achieves a true positive rate of 84.0% and a true negative rate of 42.9%, while the algorithms achieve corresponding rates of 100% and 0%. |
| 2024 | MedCLIP-ViT baseline | zero-shot image classification performance | 0.5942 | 0-shot · prompt=manual prompt ensemble · backbone=ViT | Exploring Low-Resource Medical Image Classification with Weakly Supervised Prompt LearningSource quoteL200: MedCLIP-ViT \cite{7} │ 0.5942 │ 0.5024 │ 0.7943 │ 0.7682 |
| 2024 | BiasAdv baseline | EO_p | 39.0 | split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL172: BiasAdv~\cite{lim2023biasadv} │ 39.0 │ 54.5 │ 58.2 │ 71.1 │ 36.0 │ 54.0 │ 77.1 │ 61.0 │ 39.0 │ 33.5 │ 36.6 │ 74.9 |
| 2024 | Batch Samp. baseline | DI disparity (|1−DI|) | 51.8 | split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0 |
| 2024 | Batch Samp. baseline | Acc | 74.3 | split: test · fine-tuned · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-base | Debiased Noise Editing on Foundation Models for Fair Medical Image ClassificationSource quoteL170: Batch Samp.~\cite{puyol2021fairness} │ 41.5 │ 50.5 │ 51.8 │ 74.3 │ 64.0 │ 72.0 │ 76.6 │ 60.5 │ 39.0 │ 43.0 │ 44.8 │ 76.0 |
| 2024 | GESTALT baseline | AUC | 70.82 | split: test · training-data=10% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL277: 70.82 |
| 2024 | GESTALT baseline | AUC | 89.27 | split: test · training-data=40% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL280: 89.27 |
| 2024 | GESTALT baseline | AUC | 96.71 | split: test · training-data=100% | Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray ClassificationSource quoteL286: 96.71 |
| 2024 | Previous image baseline non-standard slice | macro-average AUROC | 0.572 | split: test · subset=Diff subset | Towards Predicting Temporal Changes in a Patient's Chest X-ray Images based on Electronic Health RecordsSource quoteL482: Previous image │ 0.768 │ 0.846 │ 0.572 |
| 2023 | GAT (Gender auxiliary task) proposed non-standard slice | Robust AUC | 83.00 | attack=PGD-10 · target=Atelectasis · auxiliary-task=Gender · perturbation-budget=ℓ∞ ε=4/255 | GAT: Guided Adversarial Training with Pareto-optimal Auxiliary TasksSource quoteL887: Atelectasis │ Gender │ 83.00 │ 83.35 |
| 2023 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposed | AUC | 89.24% | split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteL41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2023 | MGA(text-level) proposed | Acc | 75.06 | view=frontal · averaged_over=8 diseases | MGA: Medical generalist agent through text-guided knowledge transformationSource quoteL114: MGA(text-level) │ 86.48 │ 81.51 │ 71.01 │ \multicolumn{1}{l}{75.06} │ \multicolumn{1}{l}{69.91} │ \multicolumn{1}{l|}{82.32} |
| 2023 | ELIXR-C proposed | Mean AUC | 0.850 | split: test · 0-shot · findings=13 | ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encodersSource quoteL434: 0.850 |
| 2023 | ELIXR-B linear proposed | Mean AUC | 0.893 | split: test · linear-probe · findings=5 · training-data=1% (~2,200 images) | ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encodersSource quoteL449: 0.893 |
| 2023 | CSDA (Ours; full proposed framework with VCQ) proposed | AUC | 0.6792 | semi-supervised · labeled-samples=500 | Class-Specific Distribution Alignment for semi-supervised medical image classificationSource quoteL406: Ours │ 0.6499 │ 0.6619 │ 0.6694 │ 0.6762 │ 0.6792 |