CheXpert

131 papers · 316 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.90.90.90.9202120222023FDAM (DenseNet161): 0.9316 (2021)FDAM (DenseNet161): 0.9333 (2021)final model (ensemble of the best performing networks): 0.94 (2021)Proposed instrumental variable learning framework: 0.923 (2023)Proposed MARL framework (Ours, ResNet): 0.925 (2023)DenseNet121-MaxAUC: 0.935 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 150 of 161 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard sliceAUROCf (failure-detection AUROC)0.487split: testCan saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L307: both models (0.487 and 0.536, with intervals including 0.5).
2026Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard sliceAUROCf (failure-detection AUROC)0.536split: test · backbone=ViT-B/16Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L307: both models (0.487 and 0.536, with intervals including 0.5).
2026MedGemma-27B (Ours; symbolic entailment filtered) proposedSoundness0.9599model=MedGemma-27B · params=27B · filtering=symbolic-entailmentToward Guarantees for Clinical Reasoning in Vision Language Models via Formal Verification
Source quote
L187: \texttt{MedGemma-27B} │ 0.9301 │ 0.9599 │ +0.0298 │ 0.8231 │ 0.8107 │ -0.0124 │ -0.0601 │ +0.0024
2026MedGemma-27B (Ours; symbolic entailment filtered) proposedCompleteness0.8107model=MedGemma-27B · params=27B · filtering=symbolic-entailmentToward Guarantees for Clinical Reasoning in Vision Language Models via Formal Verification
Source quote
L187: \texttt{MedGemma-27B} │ 0.9301 │ 0.9599 │ +0.0298 │ 0.8231 │ 0.8107 │ -0.0124 │ -0.0601 │ +0.0024
2026MedCLIP + GazeWorld proposedAccuracy59.420-shot · subset=5×200A World Model of Radiologist Reading for Medical Image Representation Learning
Source quote
L682: 58.13 │ 59.42 │ 56.85
2026VIVID-Med proposedmacro-AUC0.8588linear-probeVIVID-Med: LLM-Supervised Structured Pretraining for Deployable Medical ViTs
Source quote
L128: Table~\ref{tab:main_combined} summarizes performance on CheXpert and NIH. In-domain, VIVID-Med achieves an exceptional 0.8588 macro-AUC on CheXpert, outperforming BiomedCLIP by {+}6.65 points despite using 500× less pretraining data. Conversely, self-supervised baselines (MAE, DINOv3) show competitive F1s but substantially lower AUCs, highlighting their inability to capture clinical ranking structures without explicit semantic guidance.
2026MedRAX + CRC-Router (TTA) proposedMacro wrong-accept risk4.6%split: testCRC-Router: Risk-Constrained Routing for Medical Agentic AI Systems
Source quote
L186: Macro Risk │ 5.7% │ 4.8% │ 3.8% │ Macro Risk │ 20.9% │ 4.6%
2026Full (Graph-of-Differences) proposedR1↑ (Rank-1)0.33590-shot · evaluation=external-transferGraph-of-Differences: Anatomy-Structured Difference Alignment for Medical Image Re-Identification
Source quote
L232: 0.9033 │ 0.8294 │ 0.3359 │ 0.3926
2026Causal conditioning (sampling) proposedAUC of pleural effusion predictor82.33generation=sampling · conditioning=causalTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2026Causal conditioning (counterfactual generation) proposedAUC of pleural effusion predictor81.67generation=counterfactual · conditioning=causalTo do($x$) or not to do($x$): Medical Image Counterfactuals for Dataset Augmentation
Source quote
L250: \multicolumn{2}{c||}{Average} │ 78.90 │ 80.65 │ 82.15 │ 82.33 │ 79.79 │ 81.54 │ 81.67
2025HiMed-3B proposedRATE (RaTEScore)0.487params=3BBeyond N-grams: A Hierarchical Reward Learning Framework for Clinically-Aware Medical Report Generation
Source quote
L287: HiMed-3B (\S) │ 0.182 │ 0.077 │ 0.032 │ 0.017 │ 0.163 │ 0.048 │ 0.157 │ 0.219 │ 0.487
2025DLDM (disentangled latent diffusion model) proposedEffectiveness Accuracy88.7%split: test · intervention=do(A=black)AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual Analysis
Source quote
L558: DLDM │ 88.7 │ 91.8 │ 93.3
2025DLDM (disentangled latent diffusion model) proposedFID score21.79FID of generated counterfactual images on the CheXpert dataset.AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual Analysis
Source quote
L617: DLDM │ 21.79 │ 25.89
2025Autonomous distillation proposedAUC0.920-shotTurning Drift into Constraint: Robust Reasoning Alignment in Non-Stationary Multi-Stream Environments
Source quote
L271: CARZero │ 0.84 │ 0.81 │ 0.92 │ 0.80 {\color[HTML]{FF0000} Ours} │ {\color[HTML]{FF0000} 0.85} │ {\color[HTML]{FF0000} 0.83} │ {\color[HTML]{FF0000} 0.92} │ {\color[HTML]{FF0000} 0.81} }
2025Synthetic+Real mix model proposedAUROC0.730split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained · evaluation-view=PAImproving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic Data
Source quote
L139: 4.3% increase on CheXpert from 0.700 (CI: 0.696-0.705) to 0.730 (CI: 0.725-0.733),
2025MedImageInsight zero-shot proposedAcc80.5%0-shot · prompt=ImpressionBeyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray Populations
Source quote
L101: Comparing the image embeddings to parts of the radiology reports revealed notable performance boosts for the adult datasets. MIMIC performed best using (5) Findings as prompt (Acc = 78.0%, MCC = 0.57). CheXpert performed slightly better using (6) Impression (Acc = 80.5%, MCC = 0.62).
2025MedImageInsight zero-shot proposedMCC0.620-shot · prompt=ImpressionBeyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray Populations
Source quote
L101: Comparing the image embeddings to parts of the radiology reports revealed notable performance boosts for the adult datasets. MIMIC performed best using (5) Findings as prompt (Acc = 78.0%, MCC = 0.57). CheXpert performed slightly better using (6) Impression (Acc = 80.5%, MCC = 0.62).
2025MedImageInsight zero-shot ensemble proposedAbsolute MCC difference across race subgroups10%0-shot · method=zero-shot ensemble · subgroup=raceBeyond the Prompt: Deploying Medical Foundation Models on Diverse Chest X-ray Populations
Source quote
L419: Figure 3 (right) illustrates the absolute MCC differences across the demographic subgroups, sex, age, and race, in the CheXpert dataset. All evaluated methods exhibited varying levels of bias, reflected in performance differences across subgroups. ZS ensembling demonstrated a notable bias reduction compared to linear probing across all variables. For linear probing, differences ranged from 10% for sex, 14% for race, and up to 24% for age. In contrast, the ZS ensemble method achieved considerably lower bias levels, with the highest observed difference of 10% for race, while bias for sex and age remained below 5%. Although the ZS performance method demonstrated improved fairness compared to linear probing, methods such as LORA and KNN exhibited even smaller differences across all variables.
2025Pragmatic listener (trained with pragmatic speaker, α=0.2) proposedListener accuracy98.72%claims=4 · classes=2 · speaker-gamma=0.4 · candidate-utterances=4 · explanations-per-input=8Aligning Explanations with Human Communication
Source quote
L121: CheXpert │ 2 │ 78.21% │ 4 │ 84.62% │ 98.72%
2025XFMamba-S (frontal and lateral; cross-fusion; CVSM and MVCM enabled) proposedAUROC0.9184views=frontal-and-lateral · epochs=100 · fusion=cross-fusion · backbone=VMamba-pretrained feature encoder · observations=13XFMamba: Cross-Fusion Mamba for Multi-view Medical Image Classification
Source quote
L130: 8 │ Frontal \ │ Lateral │ cross-fusion │ \usym{2713} │ \usym{2713} │ 0.9184
2025ALTA proposedAccuracy56.6%0-shot · subset=5×200 · resolution=224Efficient Medical Vision-Language Alignment Through Adapting Masked Vision Models
Source quote
L286: Our ALTA │ 224 │ 83.2 │ 77.9 │ 91.0 │ 56.6
2025ALTA (adapter training) proposedP@5, text-to-image retrieval64.5subset=8×200 · adapter=trained · patches=all retainedEfficient Medical Vision-Language Alignment Through Adapting Masked Vision Models
Source quote
L529: Adapter training │ 51.3 │ 47.1 │ \multicolumn{1}{c|}{38.7} │ 64.5 │ 65.8 │ \multicolumn{1}{c|}{53.0} │ 56.8 │ 55.4 │ 46.8
2025ALTA (adapter training) proposedP@5, image-to-text retrieval56.8subset=5×200 · adapter=trained · patches=all retainedEfficient Medical Vision-Language Alignment Through Adapting Masked Vision Models
Source quote
L529: Adapter training │ 51.3 │ 47.1 │ \multicolumn{1}{c|}{38.7} │ 64.5 │ 65.8 │ \multicolumn{1}{c|}{53.0} │ 56.8 │ 55.4 │ 46.8
2025ART-ASyn proposedAP0.8639Image-level anomaly detection.ART-ASyn: Anatomy-aware Realistic Texture-based Anomaly Synthesis Framework for Chest X-Rays
Source quote
L204: On the CheXpert dataset, ART-ASyn achieves an AP of 0.8639 and an AUC of 0.7125. It surpasses the second-best method in AP, UniAS, which achieves 0.7926, marking an improvement of 0.0713. While ART-ASyn achieves consistent gains on most metrics, its AUC on CheXpert is lower than AnatPaste's score of 0.7825. This discrepancy may be attributed to the base model architecture, as further discussed in the ablation study.
2025EWC-Guided Diffusion Replay (DDPM+EWC) proposedAUROC0.851split: valEWC-Guided Diffusion Replay for Exemplar-Free Continual Learning in Medical Imaging
Source quote
L4: Medical imaging foundation models must adapt over time, yet full retraining is often blocked by privacy constraints and cost. We present a continual learning framework that avoids storing patient exemplars by pairing class conditional diffusion replay with Elastic Weight Consolidation. Using a compact Vision Transformer backbone, we evaluate across eight MedMNIST v2 tasks and CheXpert. On CheXpert our approach attains 0.851 AUROC, reduces forgetting by more than 30% relative to DER\texttt{++}, and approaches joint training at 0.869 AUROC, while remaining efficient and privacy preserving. Analyses connect forgetting to two measurable factors: fidelity of replay and Fisher weighted parameter drift, highlighting the complementary roles of replay diffusion and synaptic stability. The results indicate a practical route for scalable, privacy aware continual adaptation of clinical imaging models.
2025Stable Diffusion proposedclassification accuracy95%retained-coverage=55% · uncertainty-filtered=45% of most uncertain samples removedConditional Diffusion Models are Medical Image Classifiers that Provide Explainability and Uncertainty for Free
Source quote
L16: In this work, we present a comprehensive evaluation of how conditional diffusion models can be re-purposed and leveraged for image classification, explainability, and uncertainty estimation in the medical domain. First, we propose a novel majority voting-based method that improves the performance of diffusion classifiers in medical imaging. We then demonstrate that classifiers derived from foundation and trained-from-scratch diffusion models perform competitively with state-of-the-art medical image discriminative classifiers through extensive experiments on the publicly available CheXpert~\cite{irvin2019chexpert} and ISIC Melanoma skin cancer~\cite{Rotemberg2020APD} datasets, despite not being trained for classification. Next, we show that diffusion classifiers offer explainability (via counterfactual generation) and uncertainty quantification (via entropy) out-of-the-box. We validate the uncertainty by showing that when the model is confident, it is correct, and vice versa. This is shown as model accuracy drastically improves as its uncertainty threshold increases. For example, Stable Diffusion reaches classification accuracies of 100% and 95% on ISIC and CheXpert, respectively, with only 45% of its most uncertain samples filtered out.
2025MV-HFMD proposedAUC-ROC0.775label-setting=average across five uncertain-label scenarios and 13 classification tasksMCD-CLIP: Multi-view Chest Disease Diagnosis with Disentangled CLIP
Source quote
L393: 0.775
2025MV-HFMD proposedTunable Param36.05 MNumber of tunable parameters reported for the method on CheXpert; not an averaged task …MCD-CLIP: Multi-view Chest Disease Diagnosis with Disentangled CLIP
Source quote
L392: 36.05
2025RR-ClArC (ResNet50) proposedAccuracy (biased)0.79split: test · artifact=brightness · backbone=ResNet-50Ensuring medical AI safety: interpretability-driven detection and mitigation of spurious model behavior and associated data
Source quote
L1119: RR-ClArC │ {0.86} \,|\, {0.97} \,|\, {0.82} │ 0.76 \,|\, 0.96 \,|\, 0.79 │ 0.42 \,|\, {0.34} \,|\, - │ 0.00 \,|\, 0.07 \,|\, 0.00
2025U-Net + Text Encoder fine-tuning proposedAccuracy94.8%split: test · subset=No Finding · resolution=512×512Pixels Under Pressure: Exploring Fine-Tuning Paradigms for Foundation Models in High-Resolution Medical Imaging
Source quote
L156: When evaluated on real test images after training on synthetic data (Table~\ref{tab:model_accuracy}), models fine-tuned on both U-Net and Text Encoder achieve the highest accuracy across nearly all disease categories (e.g., 77.9% for Cardiomegaly, 94.8% for No Finding), highlighting strong generalization. BitFit also performs surprisingly well in this evaluation, suggesting that while it may underperform in generation quality, its generated images still retain enough semantic structure to be informative for downstream classification. LoRA and DoRA also demonstrate robust cross-domain transfer, particularly in high-signal classes such as Pneumothorax and No Finding, underscoring their utility as efficient yet effective fine-tuning alternatives.
2025CLIP fine-tuned with Palm2-bison fine-grained captions proposedaverage per-class accuracy (Avg)72.5%0-shot · backbone=CLIP · caption-source=Palm2-bison · caption-granularity=fineEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L116: Palm2-bison~\cite{anil2023palm} │ fine │ 74.6 │ 70.7 │ 72.4 │ 77.6 │ 56.9 │ 84.5 │ 70.3 │ 80.2 │ 93.1 │ 37.1 │ 79.7 │ 72.5
2025CLIP fine-tuned with Zephyr-7b coarse-grained captions proposedaverage per-class accuracy (Avg)53.2%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=coarseEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L127: coarse │ 65.9 │ 41.8 │ 78.9 │ 56.9 │ 42.7 │ 85.8 │ 49.1 │ 71.6 │ 85.8 │ 3.4 │ 3.4 │ 53.2
2025CLIP fine-tuned with Zephyr-7b medium-grained captions proposedaverage per-class accuracy (Avg)56.8%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=mediumEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L126: medium │ 66.4 │ 40.5 │ 82.8 │ 81.5 │ 48.7 │ 85.3 │ 46.1 │ 71.6 │ 85.3 │ 3.9 │ 12.9 │ 56.8
2025CLIP fine-tuned with Zephyr-7b fine-grained captions proposedaverage per-class accuracy (Avg)64.1%0-shot · params=7b · backbone=CLIP · caption-source=Zephyr-7b · caption-granularity=fineEnhancing Chest X-ray Classification through Knowledge Injection in Cross-Modality Learning
Source quote
L125: \multirow[t]{3}{*}{zephyr-7b~\cite{tunstall2023zephyr}} │ fine │ 67.7 │ 43.1 │ 60.3 │ 60.3 │ 56.5 │ 83.2 │ 78.4 │ 79.3 │ 86.2 │ 62.5 │ 28.0 │ 64.1
2025Diff3M (Ours_demo) proposedAUPRC0.931split: test · variant=Ours_demo · sampling=600-step DDIM · demographics=usedHarnessing EHRs for Diffusion-Based Anomaly Detection on Chest X-Rays
Source quote
L181: AUPRC │ 0.888 │ 0.719 │ 0.889 │ 0.917 │ 0.931
2025AdvSimplex (Medical CLIP, CheXzero paradigm, ViT-B) proposed non-standard slicePGD AUC0.7350-shot · attack=PGD-20 · epsilon=1/255 · backbone=ViT-BImproving Zero-Shot Adversarial Robustness in Vision-Language Models by Closed-form Alignment of Adversarial Path Simplices
Source quote
L1165: 0.735
2025Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposedCFRT (Classifier Flip Rate along a Trajectory)0.78fine-tuned · trajectory=style · target-attribute=Pleural EffusionLanguage-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image Generation
Source quote
L101: \multicolumn{1}{c|}{\multirow{2}{*}{CFRT\uparrow}} │ \multirow{2}{*}{0.78} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.89}} │ MEL │ 0.91 │ 0.99 │ 0.59 │ 0.74
2025Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposedCFRT (Classifier Flip Rate along a Trajectory)0.89fine-tuned · trajectory=style · target-attribute=Support DevicesLanguage-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image Generation
Source quote
L101: \multicolumn{1}{c|}{\multirow{2}{*}{CFRT\uparrow}} │ \multirow{2}{*}{0.78} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.89}} │ MEL │ 0.91 │ 0.99 │ 0.59 │ 0.74
2025Fine-tuned Stable Diffusion with language-guided latent trajectory traversal proposedLPIPS0.24fine-tuned · trajectory=style · target-attribute=Pleural EffusionLanguage-Guided Trajectory Traversal in Disentangled Stable Diffusion Latent Space for Factorized Medical Image Generation
Source quote
L103: \multicolumn{1}{c|}{\multirow{2}{*}{LPIPS\downarrow}} │ \multirow{2}{*}{0.24} │ \multicolumn{1}{c|}{\multirow{2}{*}{0.05}} │ MEL │ 0.08 │ 0.09 │ 0.12 │ 0.11
2025SiP, cross-center reference selection (CC) proposedBAcc.68.43finding=pneumonia · reference-source=MIMIC-CXR · reference-selection=cross-centerSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64
2025SiP, cross-center reference selection (CC) proposedF167.15finding=pneumonia · reference-source=MIMIC-CXR · reference-selection=cross-centerSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64
2025SiP, cross-center reference selection (CC) proposedBAcc.77.90finding=edema · reference-source=MIMIC-CXR · reference-selection=cross-centerSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64
2025SiP, cross-center reference selection (CC) proposedF179.04finding=edema · reference-source=MIMIC-CXR · reference-selection=cross-centerSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L292: CC │ 68.43 │ 67.15 │ 91.58 │ 95.83 │ 77.90 │ 79.04 │ 97.24 │ 98.64
2025SiP, random reference selection (RS) proposedBAcc.68.70finding=pneumonia · reference-selection=randomSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L295: RS │ 68.70 │ 67.05 │ \multicolumn{1}{c}{---} │ \multicolumn{1}{c}{---}
2025SiP, random reference selection (RS) proposedBAcc.78.04finding=edema · reference-selection=randomSee-in-Pairs: Reference Image-Guided Comparative Vision-Language Models for Medical Diagnosis
Source quote
L296: 78.04 │ 79.10 │ \multicolumn{1}{c}{---} │ \multicolumn{1}{c}{---}
2025AGA proposedPrec@550.28subset=5×200AGA: An adaptive group alignment framework for structured medical cross-modal representation learning
Source quote
L237: AGA │ 50.28 │ 49.84 │ 43.80
2025AGA proposedAUC56.10linear-probe · labeled-data=1%AGA: An adaptive group alignment framework for structured medical cross-modal representation learning
Source quote
L274: AGA │ 56.10 │ 61.31 │ 84.32 │ 68.91 │ 75.78 │ 87.92
2024HybridMED proposedAcc0.4480-shot · subset=5×200 · pretraining-dataset=MIMIC-CXRAdvancing Medical Radiograph Representation Learning: A Hybrid Pre-training Paradigm with Multilevel Semantic Granularity
Source quote
L201: Ours │ MIMIC-CXR │ 0.800 │ 0.448
2024FactMM-RAG proposedF1CheXbert0.491retrieval-setting=multimodalFact-Aware Multimodal Retrieval Augmentation for Accurate Medical Radiology Report Generation
Source quote
L269: FactMM-RAG │ 0.605 │ 0.249 │ 0.297 │ 0.547 │ 0.491 │ 0.174 │ 0.237 │ 0.467
2024FactMM-RAG proposedF1RadGraph0.174retrieval-setting=multimodalFact-Aware Multimodal Retrieval Augmentation for Accurate Medical Radiology Report Generation
Source quote
L269: FactMM-RAG │ 0.605 │ 0.249 │ 0.297 │ 0.547 │ 0.491 │ 0.174 │ 0.237 │ 0.467
2024MGCA with 2x synthetic augmentation using single-disease prompts proposed non-standard slicemean F1 score0.289split: test · 1-shot · prompt=single-disease · backbone=MGCA · training-data=1% ground-truth · synthetic-augmentation=2xEvaluating and Improving the Effectiveness of Synthetic Chest X-Rays for Medical Image Analysis
Source quote
L34: In multilabel classification on CheXpert dataset, we also found it was most effective to generate the synthetic data using single-disease prompts (e.g. "cardiomegaly"), and the synthetic data was used to balance all classes to the count of the most frequent disease class. At 1% ground truth data, the mean F1 score increased from 0.209 with real data to 0.289 with 2x synthetic data. At 10% ground truth data, the F1 score improved from 0.255 to 0.323 with 2x synthetic data. At 100% ground truth data, synthetic data provided marginal improvements, with the F1 score increasing from 0.310 to 0.354 with balanced 2x synthetic augmentation (Figure \ref{fig:results}, Plot 4). These results demonstrate that the strategic addition of synthetic data can address class imbalance and significantly improve multilabel classification performance, especially in low-resource scenarios.
2024GCD g-direction proposedFR(\uparrow)91.1%split: val · directions-per-disease=1Global Counterfactual Directions
Source quote
L183: Pleural effusion │ \makecell{0.7863} │ \makecell{0.4126} │ \makecell{91.1}
2024GCD g-direction proposedFR(\uparrow)91.4%split: val · directions-per-disease=1Global Counterfactual Directions
Source quote
L184: Lung opacity │ \makecell{0.8430} │ \makecell{0.2171} │ \makecell{91.4}
2024GCD g-direction proposedFR(\uparrow)89.4%split: val · directions-per-disease=1Global Counterfactual Directions
Source quote
L185: Support devices │ \makecell{0.8247} │ \makecell{0.2321} │ \makecell{89.4}
2024LLaVA-Med (PT2) proposedF123.2split: test · prompt=PT2 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L242: F1 │ 23.2 │ 42.6
2024LLaVA-Med (PT3) proposedF142.6split: test · prompt=PT3 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L242: F1 │ 23.2 │ 42.6
2024LLaVA-Med (PT2) proposedfalse positive count410 countsplit: test · prompt=PT2 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L263: Edema │ 410 │ 88
2024LLaVA-Med (PT3) proposedfalse positive count88 countsplit: test · prompt=PT3 · category=EdemaPrompting Medical Large Vision-Language Models to Diagnose Pathologies by Visual Question Answering
Source quote
L263: Edema │ 410 │ 88
2024EGMA proposedAcc.60.500-shot · subset=5x200Eye-gaze Guided Multi-modal Alignment for Medical Representation Learning
Source quote
L293: EGMA(Ours) │ 60.50 │ 58.44 │ 57.81 │ {36.70} │ 63.62 │ 61.46
2024EGMA proposedF158.440-shot · subset=5x200Eye-gaze Guided Multi-modal Alignment for Medical Representation Learning
Source quote
L293: EGMA(Ours) │ 60.50 │ 58.44 │ 57.81 │ {36.70} │ 63.62 │ 61.46
2024Attri-Net (unguided) proposedConfounder sensitivity0.747split: test · unguided · subset=synthetic shortcut test images · contamination=50% of cardiomegaly-positive samplesAttri-Net: A Globally and Locally Inherently Interpretable Model for Multi-Label Classification Using Class-Specific Counterfactuals
Source quote
L363: Since we have introduce a known shortcut behaviour on the tag signal, we expect a global explanation to correctly highlight the reliance on the tag signal in contaminated test images. To measure this we have previously introduced the confounder sensitivity metric~\citep{sun2023right}. Confounder sensitivity measures how many of the top 10% most significant pixels identified by the explanation fall on the synthetically added tag signal. We computed the confounder sensitivity using the positive class center of cardiomegaly, resulting in a score of 0.747. This indicates that 74.7% of
2024Attri-Net (with guidance) proposedConfounder sensitivity0.002split: test · guided · subset=synthetic shortcut test images · contamination=50% of cardiomegaly-positive samplesAttri-Net: A Globally and Locally Inherently Interpretable Model for Multi-Label Classification Using Class-Specific Counterfactuals
Source quote
L366: To further verify that adding guidance can direct the model towards using the correct features, we added the guidance shown in Fig.~\ref{fig:guidance_shortcut}(c) to the model to encourage the model to avoid using spurious signals. After adding guidance, the confounder sensitivity of the new class center dropped to 0.002, which means that the most significant explanation pixels are not on the spurious signals anymore.
2024Fair Diagnosis (ResNet50) proposedACC86.40%split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=genderFair Diagnosis: Leveraging Causal Modeling to Mitigate Medical Bias
Source quote
L283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34
2024Fair Diagnosis (ResNet50) proposed non-standard sliceADF (column label: ADF-e-3)1.34split: test · η=0.2 · backbone=ResNet50 · metric_scale=e-3 · train_test_split=90/10 · sensitive_attribute=genderFair Diagnosis: Leveraging Causal Modeling to Mitigate Medical Bias
Source quote
L283: Resnet50 │ 86.40 │ 66.34 │ 1.12 │ 1.41 │ 1.34
2024RadGazeGen proposedAUC (Avg across 12 pathologies)71.33split: test · classes=12 pathologies · sample-size=500RadGazeGen: Radiomics and Gaze-guided Medical Image Generation using Diffusion Models
Source quote
L207: RadGazeGen │ 80.71 │ 70.34 │ 77.67 │ 73.47 │ 66.57 │ 88.20 │ 78.31 │ 53.29 │ 77.46 │ 62.74 │ 52.32 │ 74.90 │ 71.33
2024ResNet50 coarse classification (5 classes) proposedMacro F1 score0.7109classes=5 · backbone=ResNet50Learning to diagnose common thorax diseases on chest radiographs from radiology reports in Vietnamese
Source quote
L906: 0.7109
2024ResNet50 fine classification (12 classes) proposedMacro F1 score0.4849classes=12 · backbone=ResNet50Learning to diagnose common thorax diseases on chest radiographs from radiology reports in Vietnamese
Source quote
L908: 0.4849
2024MedPrompt-ViT proposedzero-shot image classification performance0.62200-shot · prompt=automatically generated · subset=five held-out classes · backbone=ViTExploring Low-Resource Medical Image Classification with Weakly Supervised Prompt Learning
Source quote
L201: MedPrompt-ViT (Ours) │ 0.6220 │ 0.5720 │ 0.7997 │ 0.7284
2024\imgedit (white-box) proposedEO_p28.5split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024\imgedit (white-box) proposedDI disparity (|1−DI|)25.6split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024\imgedit (white-box) proposedAcc75.1split: test · fine-tuned · epochs=50 · lambda=0.01 · tuning=classifier-head · encoder=frozen · backbone=self-supervised ViT-baseDebiased Noise Editing on Foundation Models for Fair Medical Image Classification
Source quote
L174: \imgedit │ 28.5 │ 23.0 │ 25.6 │ 75.1 │ 38.0 │ 25.0 │ 34.7 │ 61.3 │ 27.5 │ 17.0 │ 19.7 │ 75.6
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC72.24split: test · training-data=10%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L289: 72.24
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC91.02split: test · training-data=40%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L292: 91.02
2024DAMLALDT (referred to as DAMLAL; Deep Taylor saliency maps) proposedAUC98.21split: test · training-data=100%Combining Graph Transformers Based Multi-Label Active Learning and Informative Data Augmentation for Chest Xray Classification
Source quote
L298: 98.21
2024UniMed-CLIP proposed non-standard sliceACC65.900-shot · subset=5x200 · backbone=CLIPUniMed-CLIP: Towards a Unified Image-Text Pretraining Paradigm for Diverse Medical Imaging Modalities
Source quote
L463: UniMed-CLIP │ 65.90 │ 71.65 │ 71.35 │ 66.31 │ 85.82 │ 85.27 │ 37.54 │ 24.43 │ 31.72
2023GAT (Gender auxiliary task) proposed non-standard sliceRobust AUC83.00attack=PGD-10 · target=Atelectasis · auxiliary-task=Gender · perturbation-budget=ℓ∞ ε=4/255GAT: Guided Adversarial Training with Pareto-optimal Auxiliary Tasks
Source quote
L887: Atelectasis │ Gender │ 83.00 │ 83.35
2023DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposedAUC89.24%split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023MGA(text-level) proposedAcc75.06view=frontal · averaged_over=8 diseasesMGA: Medical generalist agent through text-guided knowledge transformation
Source quote
L114: MGA(text-level) │ 86.48 │ 81.51 │ 71.01 │ \multicolumn{1}{l}{75.06} │ \multicolumn{1}{l}{69.91} │ \multicolumn{1}{l|}{82.32}
2023ELIXR-C proposedMean AUC0.850split: test · 0-shot · findings=13ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L434: 0.850
2023ELIXR-B linear proposedMean AUC0.893split: test · linear-probe · findings=5 · training-data=1% (~2,200 images)ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L449: 0.893
2023CSDA (Ours; full proposed framework with VCQ) proposedAUC0.6792semi-supervised · labeled-samples=500Class-Specific Distribution Alignment for semi-supervised medical image classification
Source quote
L406: Ours │ 0.6499 │ 0.6619 │ 0.6694 │ 0.6762 │ 0.6792
2023M-FLAG proposedAUC64.4%fine-tuned · labeled-data=1%M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry Optimization
Source quote
L112: M-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7
2023Proposed instrumental variable learning framework proposedMean AUC0.923split: val · uncertain-labels=mapped-to-1Instrumental Variable Learning for Chest X-ray Classification
Source quote
L219: Mean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.923
2023Proposed MARL framework (Ours, ResNet) proposedMean AUC0.925split: val · backbone=ResNet · aggregation=maximum probability across views · model-count=single-model · label-handling=uncertain labels mapped to 1Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidance
Source quote
L319: Mean AUC │ 0.889 │ 0.893 │ 0.894 │ 0.917 │ 0.920 │ 0.925
2023PTUnifier proposedAUROC90.1split: valTowards Unifying Medical Vision-and-Language Pre-training via Soft Prompts
Source quote
L288: \multirow{-3}{*}{Study_2} │ 88.1 │ 88.6 │ 77.8 │ 45.1 │ 10.5 │ 14.5 │ 11.3 │ 72.0 │ 77.9 PTUnifier (ours) │ 90.1 │ 90.6 │ 80.0 │ 46.2 │ 10.7 │ 21.0 │ 20.8 │ 78.3 │ 85.2 │ 79.3 }}
2023EEEA-Net-C2 student (DenseNet161 teacher) proposedAUC87.1%split: val · student=EEEA-Net-C2 · teacher=DenseNet161Explainable Knowledge Distillation for On-device Chest X-Ray Classification
Source quote
L6: \begin{abstract} Automated multi-label chest X-rays (CXR) image classification has achieved substantial progress in clinical diagnosis via utilizing sophisticated deep learning approaches. However, most deep models have high computational demands, which makes them less feasible for compact devices with low computational requirements. To overcome this problem, we propose a knowledge distillation (KD) strategy to create the compact deep learning model for the real-time multi-label CXR image classification. We study different alternatives of CNNs and Transforms as the teacher to distill the knowledge to a smaller student. Then, we employed explainable artificial intelligence (XAI) to provide the visual explanation for the model decision improved by the KD. Our results on three benchmark CXR datasets show that our KD strategy provides the improved performance on the compact student model, thus being the feasible choice for many limited hardware platforms. For instance, when using DenseNet161 as the teacher network, EEEA-Net-C2 achieved an AUC of 83.7%, 87.1%, and 88.7% on the ChestX-ray14, CheXpert, and PadChest datasets, respectively, with fewer parameters of 4.7 million and computational cost of 0.3 billion FLOPS.
2023PRIOR proposedAccuracy34.900-shot · subset=5x200 · ensemble=none · prompting=simple prompt engineeringPRIOR: Prototype Representation Joint Learning from Medical Images and Reports
Source quote
L211: PRIOR (ours) │ \textcolor{red}{\bf{34.90}} │ \textcolor{red}{\bf{30.56}} │ \textcolor{blue}{35.88}
2023PIE proposedfinal disease classification confidence score0.690split: test · seeds=5 · steps=10 · classes-averaged=5PIE: Simulating Disease Progression via Progressive Image Editing
Source quote
L150: In order to demonstrate the superior performance of PIE in disease progression simulation over other single-step editing methods, we perform experiments on three datasets previously mentioned. For each disease in these datasets, we used 10 healthy samples in the test set as simulation start point and run PIE, SD Video, Extrapolation with 5 random seeds. We obtain at least 50 disease imaging trajectories for each patient. Table~\ref{tab:performance} showcases that PIE consistently surpasses both SD Video and Extrapolation in terms of disease confidence scores while maintaining high CLIP-I scores. For Chexpert dataset, the 0.690 final confidence score is the average score among 5 classes. For Diabetic Retinopathy and ISIC 2018 datasets, we compare PIE with SD Video, Extrapolation for editing image to the most common seen class since these datasets are highly imbalanced. Figure~\ref{fig:comp_plots} illustrates the evolution of disease confidence scores during the progression simulation in each step. We observe that PIE is able to produce more faithful and realistic progressive editing compared to the other two baselines. Interestingly, while the CLIP-I score of Extrapolation is comparable to that of PIE, it fails to effectively edit the key disease features of the input images as its confidence scores are low throughout and at the end of the progression. We also visualize the absolute differences between initial stage and each progression stage of Cardiomegaly in Figure.~\ref{fig:progression_heatmap_visualization}.
2023KAD proposedMatthews Correlation Coefficient (MCC)0.613split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023KAD proposedMatthews Correlation Coefficient (MCC)0.666split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023KAD proposedMatthews Correlation Coefficient (MCC)0.702split: test · 0-shotKnowledge-enhanced visual-language pre-training on chest radiology images
Source quote
L449: In particular, on atelectasis (KAD 0.613 (95% CI 0.567, 0.659) vs. Radiologists 0.548), edema (KAD 0.666 (95% CI 0.608, 0.724) vs. Radiologists 0.507) and pleural effusion (KAD 0.702 (95% CI 0.653, 0.751) vs. Radiologists 0.548). On consolidation (Radiologists 0.359 (95% CI 0.262, 0.444) vs. KAD 0.357), our model is slightly worse, but not statistically significantly.
2023ShorT (binary race prediction head) proposedTwo-sided Spearman rank correlation (race-prediction AUROC vs equalized odds)0.469target=cardiomegaly · attribute=binary-raceDetecting shortcut learning for fair medical AI using shortcut testing
Source quote
L64: Using the public dataset CheXpert20, we predicted cardiomegaly from chest x-rays as a binary outcome. Following the work in Gichoya et al.13, we investigated whether the representation of race (self-reported binary attribute, Black or White) led to shortcutting in our model. Our results showed that shortcutting was present (⍴=0.469, p<0.001, Figure 5), with fairness (here estimated via equalized odds) depending strongly on the model’s encoding of race (estimated by the AUROC of race prediction). Contrary to the biased dataset for Effusion, we however note that there is no apparent trade-off between the model’s clinical performance and
2023MPMA (full configuration: image reconstruction, report reconstruction, GLA, and MA-CMF) proposedAUC90.6Component ablation study; full MPMA configuration. The caption identifies CheXpert AUC …Multi-Task Paired Masking With Alignment Modeling for Medical Vision-Language Pre-Training
Source quote
L230: \surd │ \surd │ \surd │ \surd │ 90.6 │ 0.295 │ 77.6
2023KAD-multi proposedaAUC0.8819split: test · averaging=macro over diseases · evaluation=in-domainUniChest: Conquer-and-Divide Pre-Training for Multi-Source Chest X-Ray Classification
Source quote
L230: KAD-multi │ 0.8431 │ 0.4077 │ 0.8905 │ 0.3457 │ 0.8819 │ 0.5912 │ 0.8713 │ 0.5626 │ 0.8716 │ 0.3698 │ 0.9390 │ 0.3202
2023MRM (ViT-B/16) proposedmean AUC88.5%fine-tuned · backbone=ViT-B/16 · labeled-data=1%Advancing Radiograph Representation Learning with Masked Record Modeling
Source quote
L186: Nonetheless, MRM consistently outperforms various baselines on all three datasets under different labeling ratios. Specifically, MRM maintains more advantages over previous pre-training methodologies when fine-tuning with limited annotations, which is quite meaningful for medical image analysis as large amounts of specialist annotations (from radiologists or clinicians) are usually hard to access. It is worth noting that MRM achieves 88.5% when using only 1% labeled data on CheXpert, better than previous counterparts with 100% annotations.
2022UnrealNAS-DARTS-RLGD proposedaccuracy85.4%training-strategy=same as Ke et al. · ImageNet-pretraining=noUnrealNAS: Can We Search Neural Architectures with Unreal Data?
Source quote
L256: UnrealNAS-DARTS-RLGD │ 4.32 │ 85.4 │ 86.1
2022UnrealNAS-DARTS-RLGD proposedaccuracy86.1%training-strategy=same as Ke et al. · ImageNet-pretraining=yesUnrealNAS: Can We Search Neural Architectures with Unreal Data?
Source quote
L256: UnrealNAS-DARTS-RLGD │ 4.32 │ 85.4 │ 86.1
2022MAE-pretrained ViT-S/16 proposedmAUC89.2%split: val · fine-tuned · backbone=ViT-S/16 · resolution=224×224Delving into Masked Autoencoders for Multi-Label Thorax Disease Classification
Source quote
L293: MAE │ ViT-S/16 │ 83.5 │ 81.8 │ 93.5 │ 94.0 │ 93.2 │ 89.2
2022Stable Diffusion fine-tuned for 60k steps at lr 1e-4, with U-Net and text encoder unfrozen (PA training set) proposedPneumothorax class score (Pneux)59.8split: test · fine-tuned · class=Pneumothorax · model=Stable Diffusion · learning-rate=1e-4 · training-steps=60k · unfrozen-components=U-Net and text encoderRoentGen: Vision-Language Foundation Model for Chest X-ray Generation
Source quote
L412: ~ lr 1e-4 │ 50 │ 6.4 │ 59.8 │ 34.4
2022FedKD (Cross-domain) proposedtest mAUC79.77%split: test · classes=8 · local-nodes=2 · local-private-data=CXR14+XpertPreserving Privacy in Federated Learning with Ensemble Cross-Domain Knowledge Distillation
Source quote
L263: CXR14+Xpert │ Xpert │ 79.77 │ 80.91 \\}
2022FedKD (Cross-domain) proposedtest mAUC80.91%split: test · classes=8 · local-nodes=6 · local-private-data=CXR14+XpertPreserving Privacy in Federated Learning with Ensemble Cross-Domain Knowledge Distillation
Source quote
L263: CXR14+Xpert │ Xpert │ 79.77 │ 80.91 \\}
2022MobileNetV3-Large (MDW; dense convolution with Winograd) proposedCommunication reduction relative to DenseNet-121 (DD)8.30×split: val · secure-inference · backbone=MobileNetV3-Large · operator=dense convolution with Winograd · inference=single-image · reference=DenseNet-121 (DD)Efficient ML Models for Practical Secure Inference
Source quote
L387: Dense │ \checkmark │ MDW │ 8.30× │ 2.91× │ 0.882
2022MobileNetV3-Large (MDW; dense convolution with Winograd) proposedAverage AUC0.882split: val · secure-inference · backbone=MobileNetV3-Large · operator=dense convolution with Winograd · patients=200 · label-handling=U-OnesEfficient ML Models for Practical Secure Inference
Source quote
L387: Dense │ \checkmark │ MDW │ 8.30× │ 2.91× │ 0.882
2022FedAD (cross-domain; 6 local nodes, 3 per dataset) proposedmAUC82.65%alpha=1 · setting=cross-domain · local-nodes=6Federated Learning With Privacy-Preserving Ensemble Attention Distillation
Source quote
L364: On CheXpert, both single domain and cross-domain distillation achieve better performance than centralized training: cross-domain learning with FedAD obtains the best mAUC of 82.65%, slightly better than FedAD training with only data from CheXpert (82.62%).
2022FedAD (CheXpert-only; K=3) proposedmAUC82.62%K=3 · alpha=1 · setting=CheXpert-onlyFederated Learning With Privacy-Preserving Ensemble Attention Distillation
Source quote
L350: \textcolor{black}{mAUC(%)} │ \textcolor{black}{82.58} │ \textcolor{black}{79.03} │ \textcolor{black}{82.94} │ \textcolor{black}{77.66} │ \textcolor{black}{82.62}
2022HeartSpot (RH)Line+Heart with a two-layer MLP proposedAUC ROC.78split: test · classifier=two-layer MLP · resolution=320×320 · training-iterations=300HeartSpot: Privatized and Explainable Data Compression for Cardiomegaly Detection
Source quote
L122: For the MLP, we observe that HeartSpot\xspace (RH)Line+Heart is preferred, giving 17 seconds per epoch (8x faster than DenseNet121) and .78 AUC ROC.
2022HeartSpot MP+HLine with DenseNet121 proposedROC AUC.84split: test · backbone=DenseNet121 · resolution=320×320 · compression=MP+HLineHeartSpot: Privatized and Explainable Data Compression for Cardiomegaly Detection
Source quote
L123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline.
2022HeartSpot MP+HLine with DenseNet121 proposedROC AUC improvement+0.01split: test · backbone=DenseNet121 · comparison=baseline DenseNet121 · compression=MP+HLineHeartSpot: Privatized and Explainable Data Compression for Cardiomegaly Detection
Source quote
L123: With DenseNet121, the HeartSpot\xspace MP+HLine method performs best at .84 ROC AUC, a +0.01 improvement over the baseline.
2022Proposed multimorbidity proxy metric learning method (Ours, With Neg. Proxies) proposedAUC0.77disease-labels=9 · negative-proxies=used · training-samples=4096Multimorbidity Content-Based Medical Image Retrieval Using Proxies
Source quote
L254: Ours (With Neg. Proxies) │ 0.77 │ 0.30 │ 0.48 │ 0.82
2022Proposed multimorbidity proxy metric learning method (Ours, With Neg. Proxies) proposednDCG0.30retrieval-k=10 · disease-labels=9 · negative-proxies=used · training-samples=4096Multimorbidity Content-Based Medical Image Retrieval Using Proxies
Source quote
L254: Ours (With Neg. Proxies) │ 0.77 │ 0.30 │ 0.48 │ 0.82
2022DOS proposedtesting AUC0.65split: test · federated-learning · setting=final-crafted-model-attackSuppressing Poisoning Attacks on Federated Learning for Medical Imaging
Source quote
L126: Figure \ref{fig3} compares all the aggregation rules under six different scenarios on the CheXpert dataset. In the No Attack case, the DOS method outperforms Krum and produces comparable results to the other methods including FedAvg, which was essentially designed for benign settings. When one of the clients was trained by flipping class label 0 to 1, all of the methods performed well with Krum having a marginal advantage. For the mixed attack case, DOS had a faster convergence rate in the beginning with a marginal drop in round 70 whereas FedAvg was compromised. When four clients transmitted random Gaussian noise, FedAvg and Trimmed Mean were compromised, whereas DOS and Coordinate-Wise-Median performed best. In the noise and scaled parameters attack, FedAvg and Trimmed Mean were compromised from the start while the Coordinate-Wise-Median's performance started deteriorating at round 60. The DOS method and Krum performed best in this scenario. In the final crafted model setting, we compared DOS only with Krum as this attack was specifcially designed against Krum. In this attack, we can clearly see that DOS significantly outperforms Krum with a testing AUC of 0.65 vs. 0.50. Table \ref{labcomp} summarizes the average AUC for all rounds and it can be observed that DOS aggregation rule performs consistently well against all attack scenarios. In contrast, all the other aggregation rules had lower accuracy values in one or more scenarios. Furthermore, it can be observed from Figure \ref{fig3} that the weights of the malicious clients (shown in red) are almost always close to zero, indicating that the DOS method is able to effectively suppress the parameter updates from malicious clients.
2022Medfusion proposedFID17.28Quantitative image-generation comparison; FID is lower-is-better.A multimodal comparison of latent denoising diffusion probabilistic models and generative adversarial networks for medical image synthesis
Source quote
L66: CheXpert │ Medfusion │ 17.28 │ 0.68 │ 0.32
2022AttFind proposedPercentage of explained images (images for which a counterfactual could be created)96%subset=600 random images · pathology=CardiomegalyCheXplaining in Style: Counterfactual Explanations for Chest X-rays using StyleGAN
Source quote
L130: Cardiomegaly │ 96% │ 95%
2022AttFind proposedPercentage of explained images (images for which a counterfactual could be created)94%subset=600 random images · pathology=Pleural EffusionCheXplaining in Style: Counterfactual Explanations for Chest X-rays using StyleGAN
Source quote
L131: Pleural Effusion │ 94% │ 91%
2022AttFind proposedSearch time12 hourssubset=600 random images per pathology · hardware=Tesla P100 GPUCheXplaining in Style: Counterfactual Explanations for Chest X-rays using StyleGAN
Source quote
L133: Search Time │ 12 hours │ 5 minutes
2021truncating final blocks of ImageNet-pretrained architectures proposedparameter efficiency (Times-Smaller)3.25xReported average for truncated pretrained architectures; the study truncates DenseNet12…CheXtransfer: Performance and Parameter Efficiency of ImageNet Models for Chest X-Ray Interpretation
Source quote
L211: \paragraph{Can models be smaller?} Yes. We find that by truncating final blocks of ImageNet-pretrained architectures, we can make models 3.25x more parameter-efficient on average without a statistically significant drop in performance. This method preserves the critical components of architecture design while cutting its size. This observation suggests model truncation may be a simple method to yield lighter models, using ImageNet pretrained weights to boost CheXpert performance. In the clinical setting, truncated models may provide value through improved parameter-efficiency and higher resolution CAMs. This change may enable deployment to low-resource clinical environments and further develop model trust through improved explainability.
2021ResNet18Minus1 (truncated ResNet18) proposedparameter efficiency (Times-Smaller)4.2xImageNet-pretrained ResNet18 with its final block truncated; Times-Smaller is the origi…CheXtransfer: Performance and Parameter Efficiency of ImageNet Models for Chest X-Ray Interpretation
Source quote
L189: For all four model families, we find that truncating the final block leads to no significant decrease in CheXpert AUC but can save 1.4x to 4.2x the parameters. Notably, truncating the final block of ResNet18 yields a model that is not significantly different (difference -0.002 (-0.008, 0.004)) in CheXpert AUC, but is {4.2x smaller}. Truncating the final two blocks of an EfficientNetB0 yields a model that is not significantly different (difference 0.004 (-0.003, 0.009)) in CheXpert AUC, but is {4.7x smaller}. However, truncating the second block and beyond in each of MNASNet, DenseNet121, and ResNet18 yields models that have statistically significant drops in CheXpert performance.
2021RadKG+ConvE proposedAUC0.835folds=3 random folds · uncertain-label-policy=positiveA Relational-learning Perspective to Multi-label Chest X-ray Classification
Source quote
L100: RadKG+ConvE │ 0.835 \\[0.25ex]
2021RadKG link-prediction formulation (scoring function not specified in this sentence) proposedAUC0.833folds=3 random folds · uncertain-label-policy=unclearA Relational-learning Perspective to Multi-label Chest X-ray Classification
Source quote
L83: Link prediction on RadKG: Assessing the ability of a straightforward relational formulation, wherein we incorporate a KG with just the \texttt{hasFinding} relation, indicating positive annotations. The proposed approach consistently outperforms our baselines and prior work in both Tables~\ref{tab:perf}a and \ref{tab:perf}b, irrespective of the chosen scoring function. ConvE marginally outperforms DistMult, but its significance cannot be ascertained due to lack of sufficient samples. Interestingly, the trend of performances when Uncertain\rightarrowPositive being inferior to Uncertain\rightarrowNegative in the discriminative approaches is flipped in the relational approaches (0.835 vs. 0.833).
2021Student from teacher proposedF1-Score0.42split: valA distillation based approach for the diagnosis of diseases
Source quote
L136: Student from teacher │ 0.69 │ 0.30 │ 0.42
2021Equal Loss Train, α=100 proposedAUC0.835split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=male · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Equal Loss Train, α=100 proposedAUC0.819split: test · fine-tuned · target=Consolidation · backbone=DenseNet121 · subgroup=female · method-setting=Equal Loss Train, α=100Technical Challenges for Training Fair Neural Networks
Source quote
L704: CO │ 0.983 │ 0.981 │ 0.003 │ 0.699 │ 0.698 │ 0.000 │ 0.835 │ 0.819 │ 0.016
2021Proposed method (HAM), ResNet50 backbone proposedMean AUC0.888split: test · backbone=ResNet50 · ensemble=no · uncertainty-labels=U-OnesLearning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis
Source quote
L760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy.
2021Proposed method (HAM), ResNet152 backbone proposedMean AUC0.895split: test · backbone=ResNet152 · ensemble=no · uncertainty-labels=U-OnesLearning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis
Source quote
L760: In Table \ref{table:auc:chexpert}, we also compare the performance of DenseNet-121 with the conditional training and label smoothing regularization (U-Ones+CT+LSR) strategies in \cite{pham2020interpreting}. Pham \normalemet al.~ \cite{pham2020interpreting} obtained mean AUC score of 0.930 on the official CheXpert testing set with the ensemble approach that combined six deep models of DenseNet-121, DenseNet-169, DenseNet-201, Inception-ResNet-v2, Xception, and NASNetLarge. In \cite{pham2020interpreting}, the DenseNet-121 with the strategies of U-Ones+CT+LSR is the single model that achieves the best performance in the official CheXpert validation set. In comparison, our method can outperform DenseNet-121 with the strategies of U-Ones+CT+LSR even with smaller backbone of ResNet50 on the same validation set. The mean AUC scores on the official test set of our method with the backbone of ResNet50 and ResNet152 are 0.888 and 0.895 respectively without the implementation of an ensemble strategy.
2021GAN-based augmentation proposedAUC (ROC-AUC)0.758split: val · 1-data · pathology=Lung LesionGAN-based Data Augmentation for Chest X-ray Classification
Source quote
L106: Lung Lesion │ 0.727 │ 0.728 │ 0.758
2021GAN-based augmentation proposedAUC (ROC-AUC)0.594split: val · 1-data · pathology=Pleural OtherGAN-based Data Augmentation for Chest X-ray Classification
Source quote
L107: 1% │ Pleural Other │ 0.566 │ 0.550 │ 0.594
2021GAN-based augmentation proposedAUC (ROC-AUC)0.656split: val · 1-data · pathology=FractureGAN-based Data Augmentation for Chest X-ray Classification
Source quote
L108: Fracture │ 0.583 │ 0.601 │ 0.656
2021Same-label misclassification identifier (LightGBM) proposedAUROC0.892split: test · disease=Pleural Effusion · models-averaged=10CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-rays
Source quote
L123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly.
2021Same-label misclassification identifier (LightGBM) proposedAUROC0.961split: test · disease=Consolidation · models-averaged=10CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-rays
Source quote
L123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly.
2021Same-label misclassification identifier (LightGBM) proposedAUROC0.924split: test · disease=Edema · models-averaged=10CheXbreak: Misclassification Identification for Deep Learning Models Interpreting Chest X-rays
Source quote
L123: We find that the ``same label" and ``all labels" identifiers perform very similarly and score the highest AUROC across all diseases, with a mean of 0.881 and 0.880, respectively. On Atelectasis, Cardiomegaly, Pleural Effusion, Consolidation and Edema, we find that the ``same label" mean AUROCs of 0.794, 0.835, 0.892, 0.961, 0.924 respectively, only differ up to 0.007 with the ``all label" mean AUROCs of 0.800, 0.830, 0.885, 0.958, 0.925. Both models achieve a mean AUROC higher than 0.9 on Consolidation and Edema, and a mean AUROC close to 0.9 on Pleural Effusion. Both score a mean AUROC close to 0.8 on Atelectasis and Cardiomegaly.
2021RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard sliceMicro F1, relation extraction0.725split: test · backbone=PubMedBERT · architecture=DYGIE++RadGraph: Extracting Clinical Entities and Relations from Radiology Reports
Source quote
L179: RadGraph Benchmark │ 0.709 │ 0.779 │ 0.588 │ 0.725 │ 0.692
2021RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard sliceMicro F1, named entity recognition0.905split: test · backbone=PubMedBERT · architecture=DYGIE++RadGraph: Extracting Clinical Entities and Relations from Radiology Reports
Source quote
L161: RadGraph Benchmark │ 0.941 │ 0.884 │ 0.714 │ 0.910 │ 0.905 │ 0.862
2021S^2MTS^2 proposedMean AUC over 14 disease classes71.58semi-supervised · labeled-data=500 samples per classSelf-supervised Mean Teacher for Semi-supervised Chest X-Ray Classification
Source quote
L219: Ours │ 66.15 │ 67.85 │ 70.83 │ 71.37 │ 71.58 }
2021Any Disease model + Random Forest on the Penultimate Layer proposedmean AUC0.879split: test · features=penultimate-layer · classifier=random-forestCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L256: 0.879 (0.849,0.901)
2021Any Disease model + Random Forest on the Final Prediction Layer proposedmean AUC0.875split: test · features=final-prediction-layer · classifier=random-forestCheXseen: Unseen Disease Detection for Deep Learning Interpretation of Chest X-rays
Source quote
L245: 0.875 (0.848,0.899)
2021CheXseg (CAM, p=0.9) proposedmIoU (Avg. IoU across 10 pathologies)0.299split: test · semi-supervised · backbone=ResNet18 · annotated-training-images=200 · pixel-labeled-example-probabilit=0.9CheXseg: Combining Expert Annotations with DNN-generated Saliency Maps for X-ray Segmentation
Source quote
L189: \multirow{2}{*}{Avg. IoU} │ CAM │ 0.163 │ 0.269 │ 0.274 │ 0.273 │ 0.290 │ 0.292 │ 0.299 │ \multirow{2}{*}{0.263}
2021Multi-source model fine-tuned locally proposed non-standard sliceAccuracy94%fine-tuned · class=pneumonia · fine-tuning-samples=80Deep Learning Models May Spuriously Classify Covid-19 from X-ray Images Based on Confounders
Source quote
L195: \multirow{1}{*}{Pneumonia} │ Chexpert │ 12% │ 94%
2021VisualCheXbert (BERT+LogReg on MIMIC-CXR, DenseNet labels) proposedAverage F1 score0.68split: test · evaluation=average across 8 conditions · training-data=MIMIC-CXR · training-labels=DenseNet labelsVisualCheXbert: Addressing the Discrepancy Between Radiology Report Labels and Image Labels
Source quote
L196: Average │ 0.61 │ 0.68 │ 0.61 │ 0.67
2021CheXpert symbol proposedAccuracy77.35%split: test · backbone=ResNet50 · test_samples=234 · vocabulary_size=100Emergent Symbolic Language Based Deep Medical Image Classification
Source quote
L105: 77.35
2021CheXpert symbol proposedF1-score0.697split: test · backbone=ResNet50 · test_samples=234 · vocabulary_size=100Emergent Symbolic Language Based Deep Medical Image Classification
Source quote
L106: 0.697
2021Cardiomegaly + 11 diseases from CheXpert proposedAUC of “Card”87.5%target-class=cardiomegaly · label-setting=alternative-class labels · additional-diseases=11Data, Assemble: Leveraging Multiple Datasets with Heterogeneous and Partial Labels
Source quote
L780: + 11 Diseases (\dagger) │ 87.5~\mkgreen{(\uparrow1.6)}
2021AuditAI proposedcertifiable pixel-space variation, relative increase22%Relative increase over pixel-based certified-training counterparts; the paper states th…Auditing AI models for Verified Deployment under Semantic Specifications
Source quote
L40: We show that \texttt{AuditAI}\xspace is applicable to training, verification, and deployment across diverse datasets: ImageNet~\citep{imagenet}, Chest X-Rays~\citep{chexpert,nihchestxray}, LSUN~\citep{lsun}, and Flicker Faces HQ (FFHQ)~\citep{stylegan}. For ImageNet, we show that \texttt{AuditAI}\xspace can train verifiably robust models which can tolerate 25%larger pixel-space variations compared to pixel-based certified-training counterparts for the same overall verified accuracy of 88%. The variations are measured as L_2 distances in the pixel-space. The respective % increase in pixel-space variations that can be certified for Chest X-Rays, LSUN, and FFHQ are 22%, 19%, 24%. We conclude with a human-study of the quality of the generative model for different ranges of latent-space variations revealing that pixel-space variations upto 62% of the nominal values result in realistic generated images indistinguishable from real images by humans.
2020final model (ensemble of the best performing networks) proposedmean AUC0.940split: val · labeling=majority vote of 3 board-certified radiologists · pathologies=5 · model-configuration=ensembleInterpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labels
Source quote
L4: The chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm]
2020proposed method (deep learning algorithm) proposedmean AUC0.930split: test · subset=independent competition reader-study test set · labeling=consensus of 5 board-certified radiologists · pathologies=5 · sample-size=500 CXR studiesInterpreting chest X-rays via CNNs that exploit hierarchical disease dependencies and uncertainty labels
Source quote
L4: The chest X-rays (CXRs) is one of the views most commonly ordered by radiologists \cite{NHS_England}, which is critical for diagnosis of many different thoracic diseases. Accurately detecting the presence of multiple diseases from CXRs is still a challenging task. We present a multi-label classification framework based on deep convolutional neural networks (CNNs) for diagnosing the presence of 14 common thoracic diseases and observations. Specifically, we trained a strong set of CNNs that exploit dependencies among abnormality labels and used the label smoothing regularization (LSR) for a better handling of uncertain samples. Our deep networks were trained on over 200,000 CXRs of the recently released CheXpert dataset~\cite{Irvin2019CheXpertAL} and the final model, which was an ensemble of the best performing networks, achieved a mean area under the curve (AUC) of 0.940 in predicting 5 selected pathologies from the validation set. To the best of our knowledge, this is the highest AUC score yet reported to date. More importantly, the proposed method was also evaluated on an independent test set of the CheXpert competition, containing 500 CXR studies annotated by a panel of 5 experienced radiologists. The reported performance was on average better than 2.6 out of 3 other individual radiologists with a mean AUC of 0.930, which had led to the current state-of-the-art performance on the CheXpert test set.\\[-0.75cm]
2020L2TL proposedMean AUC across five classes90.0fine-tuned · backbone=DenseNet-121 · evaluation=ten-crop · ensemble-checkpoints=30Learning to Transfer Learn: Reinforcement Learning-Based Selection for Adaptive Transfer Learning
Source quote
L583: 90.0
2020CAN proposedAverage AUROC0.768views=frontal-only · labels=14-label · uncertain-labels=U-OnesMulti-label Thoracic Disease Image Classification with Cross-Attention Networks
Source quote
L160: Average │ 0.734 │ 0.759 │ 0.760 │ 0.768 │ 0.746 │ 0.750 │ 0.752 │ 0.775
2020CAN proposedAverage AUROC0.775views=frontal-and-lateral-equally · labels=14-label · uncertain-labels=U-OnesMulti-label Thoracic Disease Image Classification with Cross-Attention Networks
Source quote
L160: Average │ 0.734 │ 0.759 │ 0.760 │ 0.768 │ 0.746 │ 0.750 │ 0.752 │ 0.775
2020DenseNet121-MaxAUC proposedMean AUC (five selected diseases)0.935split: val · subset=five selected diseases · backbone=DenseNet121 · training-method=PES-AdaGradFast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL Condition
Source quote
L302: DenseNet121-MaxAUC │ 0.901 │ 0.954 │ 0.954 │ 0.910 │ 0.957 │ 0.935
2020MaxAUC proposedAUC0.922split: test · subset=five diseases · evaluation=competition private testing setFast Objective & Duality Gap Convergence for Non-Convex Strongly-Concave Min-Max Problems with PL Condition
Source quote
L293: It is notable that the current winner~\cite{pham2019interpreting} use all diseases and conditional training that incorporates the hierarchical taxonomy of 14 diseases to train deep networks, and they use an ensemble of 6 networks. In contrast, we only use the 5 diseases and train deep networks for each disease separately without using the domain knowledge. The final results in Table~\ref{table:chexpert} show that our ensemble model by AUC maximization has a better validation AUC than the current winner, and also improves the ensemble of based models trained by Adam by 1% on average. From the table, we also see that our method achieves the highest AUC on Edema, Consolidation, Atelectasis, competitive AUC on Pleural Effusion and slightly worse AUC on Cardiomegaly. On August 4, 2020, we submitted our models (MaxAUC) for evaluation on private testing set and the results ranks 35th on the CheXpert competition with an AUC of 0.922 on private testing set.
2020ChexRadiNet proposedMean AUC0.890Classification; mean column in the CheXpert AUC table.Using Radiomics as Prior Knowledge for Thorax Disease Classification and Localization in Chest X-rays
Source quote
L195: ChexRadiNet │ 0.831 │ 0.848 │ 0.920 │ 0.930 │ 0.921 │ 0.890