NeurIPS 2026Coming to NeurIPS in Sydney?Explore papers, orals & directions

Martin Uecker

Graz University of Technology
1 previous affiliation
157Machine learning papers tracked by Lacuna
Is this you?

Research Overview

Martin Uecker focuses on the development of advanced medical imaging technologies, with a primary emphasis on Magnetic Resonance Imaging (MRI) reconstruction, biophysical modeling, and real-time cardiovascular imaging. His research integrates mathematical optimization, physics-informed modeling, and high-performance computing to improve the speed, accuracy, and clinical utility of in-vivo imaging. By moving beyond traditional Fourier-based reconstruction toward nonlinear inversion and model-based approaches, his work addresses fundamental limits in image acquisition speed and motion robustness.

Research Trajectory

The evolution of Uecker’s work reflects a consistent progression from fundamental signal processing and sensor theory toward complex, physics-integrated medical imaging systems. While early work in 2000 touched upon the theoretical and experimental investigation of solar radiation measurements, his primary academic trajectory began with the development of high-speed MRI techniques.

In the early 2010s, Uecker’s research established a foundation for real-time MRI. This period was characterized by the integration of non-Cartesian sampling—specifically radial trajectories—with iterative reconstruction algorithms. A key contribution during this time was the development of Motion Robustness through Non-Cartesian K-Space Sampling, which allowed for the acquisition of high-resolution images even in the presence of physiological motion. This was achieved through the use of nonlinear inverse reconstruction, a method that jointly estimates image content and coil sensitivity maps, thereby overcoming the limitations of traditional parallel imaging.

By the mid-2010s, the focus shifted toward the creation of robust computational frameworks to support the broader imaging community. This led to the development of the Berkeley Advanced Reconstruction Toolbox (BART), a comprehensive library for image reconstruction. This work addressed the challenges of Robust Sparse Recovery under Sensing Matrix Uncertainty, providing researchers with the tools to implement complex iterative algorithms efficiently. During this phase, Uecker’s work also delved into the mathematical properties of high-dimensional data, exploring Global Low Rank and Local Smoothness for Tensor Recovery to improve the reconstruction of dynamic imaging sequences.

In the late 2010s and early 2020s, the research trajectory moved toward clinical validation and the development of quantitative MRI (qMRI). Uecker collaborated on studies applying real-time cardiovascular magnetic resonance (CMR) to specific pathologies, such as Tetralogy of Fallot and aortic stenosis. These applications demonstrated the practical utility of Eliminating Breath-Hold Constraints in Dynamic MRI, enabling diagnostic-quality imaging during free-breathing or physical exercise.

Most recently, Uecker has pioneered model-based reconstruction techniques that incorporate the fundamental physics of the Bloch equations directly into the reconstruction process. This shift represents a move away from "fit-after-reconstruction" workflows toward a unified framework where tissue parameters (such as T1 and T2 relaxation times) are estimated directly from raw k-space data. This current phase also explores the intersection of classical physics-based models and modern machine learning, specifically through Physics-Informed Generative Priors for Imaging Inverse Problems.

Current Directions

Uecker’s current research is organized around several key pillars at the Institute of Biomedical Imaging:

Model-Based Reconstruction and Quantitative MRI A central theme of current work is the refinement of model-based reconstruction for quantitative MRI. By using nonlinear inversion of the Bloch equations, the group aims to create "universal" frameworks for tissue property mapping. This includes developing efficient simulation techniques, such as those based on precomputed state-transition matrices, to solve the time-dependent coefficients of the Bloch equations without the prohibitive computational cost of traditional ODE solvers.

Real-Time and Motion-Resolved Imaging The group continues to advance methods for free-breathing and exercise-stress CMR. This involves the development of motion-resolved model-based reconstruction, which categorizes data into different respiratory or cardiac phases to eliminate blurring and ghosting artifacts. These techniques are particularly relevant for pediatric patients or those with advanced cardiovascular disease who cannot comply with long breath-hold instructions.

Software and Digital Reference Objects The ongoing development of BART remains a priority, with recent efforts focusing on the creation of Digital Reference Objects (DROs). These tools allow for the simulation of complex, reproducible datasets using Bézier curves and analytical k-space data, providing a rigorous environment for testing new reconstruction and calibration algorithms.

Nuclear Quadrupole Resonance (NQR) Beyond traditional MRI, Uecker is exploring Nuclear Quadrupole Resonance as a novel contrast mechanism. This research, part of the CONQUER project, investigates the cross-relaxation between protons and large quadrupolar nuclei. The goal is to design smart contrast agents that can be switched on and off by changing the resonance conditions, potentially pushing the limits of molecular imaging.

Machine Learning and Generative Models The lab is increasingly integrating generative AI into the reconstruction pipeline. Unlike "black-box" deep learning, this approach focuses on Enforcing Temporal Causality with Causal Attention Masking and other physics-informed priors. These models are designed to respect the underlying physical constraints of the MRI signal while leveraging the denoising and interpolation capabilities of modern neural networks.

Representative Work

Real‐time phase‐contrast MRI of cardiovascular blood flow using undersampled radial fast low‐angle shot and nonlinear inverse reconstruction This work introduced a method for real-time phase-contrast MRI that eliminated the need for ECG synchronization. By combining flow-encoding gradients with highly undersampled radial acquisitions and nonlinear inverse reconstruction, the study demonstrated the ability to quantify blood flow in the ascending aorta during a single cardiac cycle. This established the feasibility of real-time hemodynamic monitoring.

BART: version 0.3.01 As a primary developer of the Berkeley Advanced Reconstruction Toolbox, Uecker provided the field with a standardized, high-performance framework for iterative image reconstruction. The toolbox includes generic implementations of optimization algorithms and multi-dimensional array operations, which have become essential for the development of compressed sensing and parallel imaging techniques.

Quantitative Magnetic Resonance Imaging by Nonlinear Inversion of the Bloch Equations In this senior-author paper, Uecker presents a framework for quantitative MRI that bypasses simplified mathematical approximations. By incorporating the Bloch equations directly into the nonlinear inversion process, the method allows for the direct estimation of physical tissue parameters from undersampled data, improving the accuracy and flexibility of parameter mapping.

Free-Breathing Myocardial T1 Mapping using Inversion-Recovery Radial FLASH and Motion-Resolved Model-Based Reconstruction This work addresses the challenge of T1 mapping in the heart, which is typically sensitive to respiratory motion. By employing a motion-resolved model-based approach, the research demonstrates that accurate T1 maps can be generated from free-breathing acquisitions, significantly reducing the burden on the patient while maintaining diagnostic quality.

Digital Reference Objects with BART This paper describes the expansion of the BART ecosystem to include sophisticated simulation tools. By enabling the creation of DROs from vector graphics and combining them with simulated signal curves, Uecker provides a pathway for the systematic validation of reconstruction algorithms against known ground truths in complex imaging scenarios.

Dynamic Transitions for Fast Joint Acquisition and Reconstruction of CEST‐Rex and T1 This recent work focuses on multi-parametric imaging, specifically the simultaneous quantification of Chemical Exchange Saturation Transfer (CEST) and T1 relaxation. The technique utilizes dynamic transitions to enable robust and efficient acquisition in a single scan, illustrating the lab's move toward comprehensive, high-speed tissue characterization.

Profile updated

TitleVenueYear
Fast and Robust Diffusion Posterior Sampling for MR Image Reconstruction Using the Preconditioned Unadjusted Langevin AlgorithmarXiv2025
Overlap‐Kernel <scp>EPI</scp> : Estimating <scp>MRI</scp> Shot‐to‐Shot Phase Variations by Shifted‐Kernel Extraction From Overlap Regions at Arbitrary k‐Space LocationsMagnetic2025
A Comprehensive Educational Course with a Portable MRI Scanner - from Hardware to MapProceedings on Cd-rom - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition2025
Real-time MRI Facilitates Accurate Quantification of Respiratory Impairment in Pompe Disease (P5-11.027)Neurology2025
Generative Künstliche Intelligenz (KI) Modellierung von synthetischen Prostata-MRT-Bilddaten mit Evaluation der Bildqualität im Vergleich zu realen T2 gewichteten, axialen Spin echo MRT-DatenRöfo2025
309PImpaired breathing in Pompe disease: real-time MRI with deep learning as novel tool to evaluate diaphragm vs. chest movement in neuromuscular disordersNeuromuscular2025
Unadjusted Langevin Sampling for Uncertainty Estimation in MRI Reconstruction - Theory and Numerical ValidationProceedings on Cd-rom - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition2025
Generative priors for MRI reconstruction trained from magnitude-only images using phase augmentationPhilosophical2025
Rapid, high‐resolution and distortion‐free R2∗ mapping of fetal brain using multi‐echo radial FLASH and model‐based reconstructionMagnetic2025
Towards Single-Shot Whole-Heart T1 Mapping Within Four SecondsProceedings on Cd-rom - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition2025

Browse all 157 papers