Unsupervised Self-Prior Embedding Neural Representation for Iterative Sparse-View CT Reconstruction

Xuanyu Tian, Lixuan Chen, Qing Wu, Chenhe Du, Jingjing Shi, Hongjiang Wei, Yuyao Zhang

Introduction

Computed Tomography (CT) is an essential diagnostic tool, yet the ionizing X-ray radiation it employs carries long-term health risks. Sparse-view CT (SVCT) aims to reduce this risk by acquiring fewer X-ray projections. However, this reduction transforms image reconstruction into a highly ill-posed inverse problem, typically resulting in images plagued by severe artifacts.

While supervised deep learning models have shown promise in SVCT reconstruction, they require massive paired datasets that are often difficult to obtain. Furthermore, these models frequently suffer from performance degradation when applied to out-of-domain (OOD) data, such as different scanner geometries or anatomical regions. Conversely, unsupervised Implicit Neural Representations (INRs) optimize a network on-the-fly to fit physical measurements without external training data, but they often struggle with instability and high-frequency artifacts in extremely sparse or noisy scenarios.

Methodology

To address these challenges, we introduce Spener (Self-prior embedding neural representation), an unsupervised framework that integrates INRs with classical iterative reconstruction algorithms, specifically the Plug-and-Play Half-Quadratic Splitting (PnP-HQS) method.

Overview of the Spener architecture, including the iterative self-prior process (a), the neural representation network (b), and the optimization framework (c, d).

The Spener architecture is built on three core components:

  1. Iterative Self-Prior: Rather than relying solely on the implicit bias of the INR, Spener utilizes the imperfect reconstruction from the previous iteration as an explicit prior. This feedback loop constrains the solution space and prevents the hallucination of artifacts.
  2. Image Prior Embedding: A CNN-based encoder extracts local features from the prior image. These features, along with spatial coordinates processed via multi-resolution hash encoding, are fed into a Multi-Layer Perceptron (MLP) to predict CT image intensity.
  3. PnP-HQS Framework: Optimization is decoupled into two alternating steps: a Data Fidelity step where the INR is optimized to match the measured sinogram, and a Regularization step where a classical denoiser (BM3D) smooths the output. This refined image then serves as the "self-prior" for the subsequent iteration.

Experimental Results

Spener was evaluated across three public datasets: the AAPM 2016 Low-Dose CT Grand Challenge (in-domain), a COVID-19 dataset (OOD geometry), and the CMB-CRC Head dataset (OOD anatomy).

Qualitative comparison of Spener against supervised and unsupervised baselines across different datasets and view counts.

Performance Highlights

  • In-Domain Accuracy: On the AAPM dataset (90 views), Spener achieved a PSNR of 37.16 dB, surpassing both the supervised state-of-the-art RegFormer (34.61 dB) and the unsupervised SCOPE (34.31 dB).
  • Out-of-Domain Robustness: Spener demonstrated significant resilience to domain shifts. On the COVID-19 dataset, it maintained a PSNR of 33.73 dB, while supervised methods like RegFormer saw substantial drops in quality (31.02 dB).
  • Noise Resilience: Under simulated low-dose conditions with high Poisson noise, Spener reached 36.17 dB PSNR, significantly outperforming both supervised and unsupervised baselines.
  • Ablation Study: Removing the iterative self-prior update resulted in a PSNR drop of over 1 dB, confirming that the feedback mechanism is vital for high-quality reconstruction.

Conclusion

Spener demonstrates that imperfect early reconstructions can serve as powerful structural priors when embedded within an iterative INR framework. By decoupling data consistency from regularization, Spener achieves superior stability and noise robustness compared to existing unsupervised methods. Its ability to outperform supervised models on out-of-domain data makes it a highly practical candidate for diverse clinical environments. Future work will focus on accelerating the iterative convergence and exploring more advanced domain encoders to further enhance reconstruction quality in other medical imaging modalities like MRI.

Summary updated

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
AAPM · datasetRegFormerPSNR32.92 dBImage Reconstruction · dose=low-dose (I₀ = 5×10⁵) · views=90
Source quote
L210: RegFormer │ 33.11/0.9173 │ 33.77/0.9256 │ 32.40/0.8865 │ 32.92/0.8901
BibTeX
@inproceedings{tian2025unsupervised,
  author = {Xuanyu Tian and Lixuan Chen and Qing Wu and Chenhe Du and Jingjing Shi and Hongjiang Wei and Yuyao Zhang},
  title = {{Unsupervised Self-Prior Embedding Neural Representation for Iterative Sparse-View CT Reconstruction}},
  booktitle = {AAAI Conference on Artificial Intelligence},
  year = {2025},
  url = {https://openreview.net/forum?id=i3bdQTiuLZ},
}
Figure