Three-dimensional position reconstruction of orthogonal-strip planar high-purity germanium detectors using maximum likelihood estimation

Qiuli Zhang, Peng Zhang, W. H. Dai, Mingxin Yang, Yang Tian, Ming Zeng, Hao Ma, Zhi Zeng

This paper presents a significant advancement in the precision of 3D position reconstruction for High-Purity Germanium (HPGe) detectors, a technology vital for medical imaging and gamma-ray astronomy. By moving away from traditional independent-dimension calculations and adopting a joint Maximum Likelihood Estimation (MLE) approach, the researchers achieved a nearly 20-fold reduction in reconstruction bias.

TL;DR

Researchers have developed a new 3D position reconstruction method for HPGe detectors that uses Maximum Likelihood Estimation (MLE) and integral-based pulse parameters. This approach mitigates "cross-dimensional interference" and electronic noise, significantly reducing systematic biases compared to traditional methods.

What Problem Does This Paper Address?

Orthogonal-strip planar HPGe detectors are prized for their excellent energy resolution and ability to pinpoint where a photon interacts within the crystal. However, the "conventional" way of finding this 3D position has two major flaws:

  1. Cross-Dimensional Interference: Standard methods reconstruct X, Y, and Z positions independently. In reality, the signal used to determine depth (Z) is influenced by the lateral (X/Y) position. Treating them as independent leads to systematic "warping" or bias in the results.
  2. Noise Sensitivity: Traditional algorithms often rely on the amplitude (peak height) of signals. In the presence of electronic noise, these peaks become jittery and unreliable, causing the spatial resolution to degrade rapidly.

Methods

The authors propose a multi-parameter-joint reconstruction method based on Maximum Likelihood Estimation (MLE). Instead of solving for each dimension one by one, the algorithm looks at a set of pulse shape parameters simultaneously to find the most likely $(x, y, z)$ coordinate.

Key technical innovations include:

  • Integral-based Parameters: Rather than looking at signal amplitudes, the team defined parameters based on the net area of the charge pulses (integrated over a 300 ns window). This acts as a natural filter against high-frequency electronic noise.
  • Four-Parameter Set: The MLE model utilizes a vector of four integral-based parameters ($S_C, S_I, S_{AX}, S_{AY}$) that describe charge collection, image signals, and lateral asymmetry.
  • Statistical Mapping: They established a mapping between these parameters and 3D positions by modeling the signals as a multivariate normal distribution, allowing the MLE to "correct" for the interference between dimensions.

Datasets

The study relied on high-fidelity simulations rather than experimental hardware data:

  • Simulation Tool: The SolidStateDetectors.jl package was used to model the electric fields, weighting potentials, and charge carrier drift within a cylindrical HPGe detector (30 mm diameter, 14 mm thickness).
  • Sampling: The researchers simulated a "central pixel" with interaction points spaced at 0.1 mm intervals.
  • Photon Energy: All simulated interactions were set to 100 keV.
  • Noise Profiles: Gaussian electronic noise was added to the simulated pulses, ranging from 1 keV to 3 keV root-mean-square (RMS).

Key Insights and Ideas

  • The "Aha" Moment on Coupling: The researchers demonstrated that the relationship between Collection Time Difference (CTD) and depth is not a single line, but a family of curves depending on X and Y. By using MLE, the algorithm effectively "chooses" the correct curve based on the lateral signal data.
  • Integration is Robust: The paper highlights that while rise-time extraction (used in conventional Z-reconstruction) fails spectacularly under high noise, integration remains stable. This is because integration is mathematically equivalent to low-pass filtering.
  • Handling Non-linearity at the Edges: Near the electrodes, signal behavior becomes non-monotonic (the signal doesn't change in a simple, straight-line fashion with position). The MLE approach handles these non-linearities much better than the polynomial fits used in older methods.

Key Results

The improvements over the conventional method are stark, especially under 1 keV RMS noise:

  • Z-Direction Bias: Reduced from 0.4 mm to 0.02 mm in the central region, and from 2 mm to 0.15 mm near the electrodes.
  • X/Y-Direction Bias: Slashed from 0.4 mm to 0.016 mm.
  • Resolution: The achieved position resolution was 0.07–0.16 mm in Z and 0.07–0.44 mm in X/Y.
  • Noise Robustness: When noise increased from 1 keV to 3 keV, the Z-resolution of the new method degraded linearly and slowly, whereas the conventional amplitude-based method's error exploded exponentially.

Limitations and Future Work

  • Simulation vs. Reality: The primary limitation is that the work is currently entirely simulation-based. Real-world factors like crystal lattice orientation effects on drift velocity (anisotropy) and localized impurities may complicate the mapping.
  • Edge Pixels: The study focused on the central region of the detector. Pixels near the physical edge of the germanium crystal may experience different field distortions not fully captured in this specific model.
  • Next Steps: The authors note that future work will focus on experimental validation using physical HPGe detector setups to confirm that these simulated gains hold up in the lab.

Summary updated

Abstract

Abstract Orthogonal-strip planar high-purity germanium (HPGe) detectors can reconstruct the three-dimensional (3D) positions of photon interactions by analyzing parameters extracted from multi-channel charge signals. The conventional method reconstructs these positions using a single amplitude-based parameter for each dimension. In this study, we introduce a multiparameter joint reconstruction method based on maximum likelihood estimation (MLE). Our method utilizes four integral-based parameters calculated from signals on the charge collection electrodes and its neighbors. The likelihood function is based on position-parameter relationships obtained from pulse shape simulation. This approach is expected to have a smaller reconstruction bias and greater robustness to electronic noise compared to the conventional method. The method was tested using a pseudo dataset generated by pulse shape simulation, with different levels of Gaussian white noise added. For 100 keV photon events under 1 keV root-mean-square (RMS) electronic noise, the maximum reconstruction bias along the Z direction (depth of the detector) was reduced from 0.4 mm to 0.02 mm in regions far from the detector edges and from 2 mm to 0.15 mm near the electrodes. The maximum reconstruction bias in the X/Y directions (parallel to the detector surface) was reduced from 0.4 mm to 0.016 mm. When tested with different noise levels, our method achieved better position resolution and less degradation compared to the conventional method using the same dataset. The achieved position resolution ranged from 0.07 mm to 0.16 mm in the Z direction and from 0.07 mm to 0.44 mm in the X/Y directions. This work provides a promising approach for 3D position reconstruction in orthogonal-strip planar HPGe detectors for applications such as medical imaging and gamma-ray astronomy.
BibTeX
@article{zhang2025three,
  author = {Qiuli Zhang and Peng Zhang and W. H. Dai and Mingxin Yang and Yang Tian and Ming Zeng and Hao Ma and Zhi Zeng},
  title = {{Three-dimensional position reconstruction of orthogonal-strip planar high-purity germanium detectors using maximum likelihood estimation}},
  journal = {Journal of Instrumentation},
  year = {2025},
  doi = {10.1088/1748-0221/20/10/p10028},
}

Loading related content...

Figure