Abstract
The DArk Matter Particle Explorer (DAMPE) is a cosmic-ray detector as well as a pair-converting $\gamma$-ray telescope. The effective area, reflecting the geometrical cross-section area, the $\gamma$-ray conversion probability and the photon selection efficiency, is important in the $\gamma$-ray analyses. In the work, we find a significant time variation in the effective area, as large as $\sim -4\%/{\rm yr}$ at 2 GeV for the high-energy trigger. We derive the data-based correction factors to the effective areas and apply corrections to both the effective areas and the exposure maps. The calibrated exposure can be $\sim 12\%$ smaller than the Monte Carlo one on average at 2 GeV. The calibration is further verified using the observation of the Vela pulsar, showing the spectral parameters with the correction are more consistent with those in the Fermi-LAT catalog than the ones without correction. All the corrections are now implemented in the latest version of the DAMPE $\gamma$-ray analysis toolkit DmpST.
Introduction: The Challenge of Detector Aging
Space-based telescopes like DAMPE operate in a harsh environment, constantly bombarded by high-energy particles. This radiation gradually damages sensitive components—specifically the Bismuth Germanate (BGO) calorimeter crystals. This "aging" causes the attenuation lengths of the crystals to decrease, which in turn raises the electronic thresholds required to trigger a detection.
The "effective area" of a telescope is a measure of its sensitivity, combining its physical size with its detection efficiency. If the trigger thresholds drift upward, the effective area shrinks. Most initial analyses rely on Monte Carlo (MC) simulations performed before or shortly after launch. If these simulations don't account for the time-varying sensitivity, long-term spectral and morphological analyses of cosmic gamma-ray sources will be biased. This research provides the first direct, data-based calibration to correct for this drift in DAMPE’s gamma-ray data.
Quantifying the Instrumental Drift
To address this, researchers used a "bottom-up" approach to derive correction factors using the "all-sky" gamma-ray flux as a stable reference. Since the total sky brightness is generally constant over years, any trend in the ratio of observed counts to MC-predicted counts indicates an instrumental drift.
The analysis revealed that the High-Energy Trigger (HET) effective area is shrinking at a rate of approximately 4% per year at 2 GeV. This drift correlates strongly with the known 2.7%/yr decrease in BGO crystal attenuation length caused by radiation bombardment in the geomagnetic field.
Energy and Angular Dependencies
The drift is not uniform across all observations. It is most severe at lower energies (around 2 GeV) and becomes negligible above 8 GeV. This was modeled using a power-law function, $f(E)$.
Furthermore, the rate of change depends on the inclination angle ($\theta$) at which a photon hits the detector. Particles traverse different amounts of BGO material depending on their angle, necessitating an enhancement factor, $g(E, \theta)$, to refine the correction. These factors were combined into a single correction formula applied to both the effective area and the exposure maps used in scientific analysis.
Verification and Impact
The new calibration was validated using observations of the Vela pulsar, the brightest gamma-ray source in the DAMPE catalog. Applying the correction significantly improved the likelihood fit ($\Delta \ln L \approx 25$) and brought the derived spectral parameters into much better alignment with the Fermi-LAT 4FGL-DR4 catalog than the uncorrected data.
An interesting "failed trigger" paradox was also observed: while the HET effective area shrinks, the "HvLET" (HET-vetoed Low-Energy Trigger) effective area actually increases slightly between 2 and 5 GeV. This occurs because photons that should have tripped the HET now "fail" into the lower-energy trigger category due to the higher thresholds.
Conclusion
This data-driven calibration is vital for high-precision studies below 8 GeV. At 2 GeV, the calibrated exposure is roughly 12% smaller than original MC-based estimates. These corrections are now fully implemented in DmpST, the standard DAMPE gamma-ray analysis toolkit, ensuring future research benefits from this increased precision.